Name | Theory_2773-2928205-358_1 |
Workunit | 229867250 |
Created | 24 Jan 2025, 6:46:18 UTC |
Sent | 24 Jan 2025, 6:47:53 UTC |
Report deadline | 4 Feb 2025, 6:47:53 UTC |
Received | 24 Jan 2025, 8:21:35 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | 1 (0x00000001) Unknown error code |
Computer ID | 10859977 |
Run time | 7 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 5.92 GFLOPS |
Application version | Theory Simulation v300.60 (vbox64_theory) windows_x86_64 |
Peak working set size | 7.73 MB |
Peak swap size | 1.81 MB |
Peak disk usage | 0.88 MB |
<core_client_version>8.0.2</core_client_version> <![CDATA[ <message> Incorrect function. (0x1) - exit code 1 (0x1)</message> <stderr_txt> 2025-01-24 07:21:00 (17348): vboxwrapper version 26208 2025-01-24 07:21:00 (17348): BOINC client version: 8.0.2 2025-01-24 07:21:00 (17348): Detected: VirtualBox VboxManage Interface (Version: 7.1.0) 2025-01-24 07:21:01 (17348): Detected: Heartbeat check (file: 'heartbeat' every 1200.000000 seconds) 2025-01-24 07:21:01 (17348): Successfully copied 'init_data.xml' to the shared directory. 2025-01-24 07:21:01 (17348): Successfully copied 'input' to the shared directory. 2025-01-24 07:21:01 (17348): Create VM. (boinc_432698a862acce62, slot#1) 2025-01-24 07:21:02 (17348): Setting Memory Size for VM. (630MB) 2025-01-24 07:21:02 (17348): Setting CPU Count for VM. (1) 2025-01-24 07:21:02 (17348): Setting Chipset Options for VM. 2025-01-24 07:21:02 (17348): Setting Graphics Controller Options for VM. 2025-01-24 07:21:03 (17348): Setting Boot Options for VM. 2025-01-24 07:21:03 (17348): Setting Network Configuration for NAT. 2025-01-24 07:21:03 (17348): Enabling VM Network Access. 2025-01-24 07:21:03 (17348): Disabling USB Support for VM. 2025-01-24 07:21:04 (17348): Disabling COM Port Support for VM. 2025-01-24 07:21:04 (17348): Disabling LPT Port Support for VM. 2025-01-24 07:21:04 (17348): Disabling Audio Support for VM. 2025-01-24 07:21:04 (17348): Disabling Clipboard Support for VM. 2025-01-24 07:21:05 (17348): Disabling Drag and Drop Support for VM. 2025-01-24 07:21:05 (17348): Adding storage controller(s) to VM. 2025-01-24 07:21:05 (17348): Adding virtual disk drive to VM. (Theory_2025_01_16_prod.vdi) 2025-01-24 07:21:07 (17348): Adding VirtualBox Guest Additions to VM. 2025-01-24 07:21:07 (17348): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2025-01-24 07:21:08 (17348): forwarding host port 61425 to guest port 80 2025-01-24 07:21:08 (17348): Enabling remote desktop for VM. 2025-01-24 07:21:08 (17348): Enabling shared directory for VM. 2025-01-24 07:21:09 (17348): Starting VM using VBoxManage interface. (boinc_432698a862acce62, slot#1) 2025-01-24 07:21:10 (17348): Error in start VM for VM: 1 Command: VBoxManage -q startvm "boinc_432698a862acce62" --type headless Output: VBoxManage.exe: error: The virtual machine 'boinc_432698a862acce62' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\1\boinc_432698a862acce62\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_432698a862acce62" to power on... 2025-01-24 07:21:10 (17348): VM failed to start. 2025-01-24 07:21:10 (17348): Could not start 2025-01-24 07:21:10 (17348): ERROR: VM failed to start 2025-01-24 07:21:10 (17348): Powering off VM. 2025-01-24 07:21:10 (17348): Deregistering VM. (boinc_432698a862acce62, slot#1) 2025-01-24 07:21:10 (17348): Removing network bandwidth throttle group from VM. 2025-01-24 07:21:10 (17348): Removing VM from VirtualBox. Hypervisor System Log: 00:00:06.910679 Platform architecture set to 'x86' 00:00:06.911917 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:06.912405 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_432698a862acce62\boinc_432698a862acce62.vbox" with version "1.19-windows" 00:00:06.916209 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_432698a862acce62\boinc_432698a862acce62.vbox" 00:00:06.916348 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:06.917765 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_432698a862acce62\boinc_432698a862acce62.vbox" with version "1.19-windows" 00:00:06.921261 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_432698a862acce62\boinc_432698a862acce62.vbox" 00:00:06.921654 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_432698a862acce62\boinc_432698a862acce62.vbox" with version "1.19-windows" 00:00:06.924674 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_432698a862acce62\boinc_432698a862acce62.vbox" 00:00:07.179022 Platform architecture set to 'x86' 00:00:07.180277 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.187047 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.187199 Saving settings file "C:\Users\Nigel\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:07.191071 Finished saving settings file "C:\Users\Nigel\.VirtualBox\VirtualBox.xml" 00:00:07.191281 Saving settings file "C:\Users\Nigel\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:07.194352 Finished saving settings file "C:\Users\Nigel\.VirtualBox\VirtualBox.xml" 00:00:07.194581 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_432698a862acce62\boinc_432698a862acce62.vbox" with version "1.19-windows" 00:00:07.196989 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_432698a862acce62\boinc_432698a862acce62.vbox" 00:00:07.448335 Platform architecture set to 'x86' 00:00:07.449341 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_432698a862acce62\boinc_432698a862acce62.vbox" with version "1.19-windows" 00:00:07.452635 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_432698a862acce62\boinc_432698a862acce62.vbox" 00:00:07.702406 Platform architecture set to 'x86' 00:00:07.703843 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_432698a862acce62\boinc_432698a862acce62.vbox" with version "1.19-windows" 00:00:07.707055 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_432698a862acce62\boinc_432698a862acce62.vbox" 00:00:08.211652 Platform architecture set to 'x86' 00:00:08.212835 VRDE: Generating certificate files 'C:\ProgramData\BOINC\slots\1\boinc_432698a862acce62\VRDEAutoGeneratedCert.pem' and 'C:\ProgramData\BOINC\slots\1\boinc_432698a862acce62\VRDEAutoGeneratedPrivateKey.pem'... 00:00:08.290168 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_432698a862acce62\boinc_432698a862acce62.vbox" with version "1.19-windows" 00:00:08.294494 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_432698a862acce62\boinc_432698a862acce62.vbox" 00:00:08.465712 Platform architecture set to 'x86' 00:00:08.466682 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_432698a862acce62\boinc_432698a862acce62.vbox" with version "1.19-windows" 00:00:08.470501 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_432698a862acce62\boinc_432698a862acce62.vbox" 00:00:08.720427 Platform architecture set to 'x86' 00:00:08.734531 ERROR [COM]: aRC=VBOX_E_NOT_SUPPORTED (0x80bb0009) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={This VM is not encrypted}, preserve=false aResultDetail=0 00:00:08.740094 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.740156 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.952065 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={bea3ef5c-de2f-4b74-aa3a-15d6249371a0} aComponent={RecordingSettingsWrap} aText={Recording not started}, preserve=false aResultDetail=0 00:00:08.953046 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:09.232993 Launched VM: 3791617680 pid: 17920 (0x4600) frontend: headless name: boinc_432698a862acce62 00:00:09.567632 Watcher ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={MachineWrap} aText={The virtual machine 'boinc_432698a862acce62' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\1\boinc_432698a862acce62\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0 00:00:09.567977 Watcher Reaper: Pid 17920 (0x4600) exited normally: 1 (0x1) 00:00:09.601031 Platform architecture set to 'x86' 00:00:09.601565 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:09.629984 Platform architecture set to 'x86' 00:00:09.630871 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_432698a862acce62\boinc_432698a862acce62.vbox" with version "1.19-windows" 00:00:09.635070 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_432698a862acce62\boinc_432698a862acce62.vbox" 00:00:09.884746 Saving settings file "C:\Users\Nigel\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:09.888588 Finished saving settings file "C:\Users\Nigel\.VirtualBox\VirtualBox.xml" 00:00:09.888645 Saving settings file "C:\Users\Nigel\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:09.892572 Finished saving settings file "C:\Users\Nigel\.VirtualBox\VirtualBox.xml" 00:00:09.893309 DeleteVM Saving settings file "C:\Users\Nigel\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:09.897416 DeleteVM Finished saving settings file "C:\Users\Nigel\.VirtualBox\VirtualBox.xml" 00:00:14.906644 main VirtualBox: object deletion starts 00:00:14.907238 main HostDnsMonitor: shutting down ... 00:00:14.907268 main HostDnsMonitor: shut down 00:00:14.908957 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d644ad1e-c501-4fc7-9ab6-aa6d763bc540} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:14.909174 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: 7348): Command: VBoxManage -q modifyvm "boinc_432698a862acce62" --memory 630 Exit Code: 0 Output: 2025-01-24 07:21:02 (17348): Command: VBoxManage -q modifyvm "boinc_432698a862acce62" --cpus 1 Exit Code: 0 Output: 2025-01-24 07:21:02 (17348): Command: VBoxManage -q modifyvm "boinc_432698a862acce62" --acpi on --ioapic on --rtcuseutc off Exit Code: 0 Output: 2025-01-24 07:21:03 (17348): Command: VBoxManage -q modifyvm "boinc_432698a862acce62" --vram 16 --graphicscontroller VBoxVGA Exit Code: 0 Output: 2025-01-24 07:21:03 (17348): Command: VBoxManage -q modifyvm "boinc_432698a862acce62" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2025-01-24 07:21:03 (17348): Command: VBoxManage -q modifyvm "boinc_432698a862acce62" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2025-01-24 07:21:03 (17348): Command: VBoxManage -q modifyvm "boinc_432698a862acce62" --cableconnected1 on Exit Code: 0 Output: 2025-01-24 07:21:04 (17348): Command: VBoxManage -q modifyvm "boinc_432698a862acce62" --usb off Exit Code: 0 Output: 2025-01-24 07:21:04 (17348): Command: VBoxManage -q modifyvm "boinc_432698a862acce62" --uart1 off --uart2 off Exit Code: 0 Output: 2025-01-24 07:21:04 (17348): Command: VBoxManage -q modifyvm "boinc_432698a862acce62" --lpt1 off --lpt2 off Exit Code: 0 Output: 2025-01-24 07:21:04 (17348): Command: VBoxManage -q modifyvm "boinc_432698a862acce62" --audio-enabled off Exit Code: 0 Output: 2025-01-24 07:21:05 (17348): Command: VBoxManage -q modifyvm "boinc_432698a862acce62" --clipboard disabled Exit Code: 0 Output: 2025-01-24 07:21:05 (17348): Command: VBoxManage -q modifyvm "boinc_432698a862acce62" --draganddrop disabled Exit Code: 0 Output: 2025-01-24 07:21:05 (17348): Command: VBoxManage -q storagectl "boinc_432698a862acce62" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2025-01-24 07:21:05 (17348): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2025_01_16_prod.vdi" Exit Code: 0 Output: UUID: 6a4110e9-e559-4c1c-bfd2-ba6f6aaf4169 Parent UUID: base State: created Type: multiattach Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\Theory_2025_01_16_prod.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 781 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-01-24 07:21:06 (17348): Command: VBoxManage -q storageattach "boinc_432698a862acce62" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2025_01_16_prod.vdi" Exit Code: -2135228409 Output: VBoxManage.exe: error: Cannot attach medium 'C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\Theory_2025_01_16_prod.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 786 of file VBoxManageStorageController.cpp 2025-01-24 07:21:06 (17348): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2025_01_16_prod.vdi" Exit Code: 0 Output: UUID: 6a4110e9-e559-4c1c-bfd2-ba6f6aaf4169 Parent UUID: base State: created Type: multiattach Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\Theory_2025_01_16_prod.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 781 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-01-24 07:21:06 (17348): Command: VBoxManage -q closemedium disk "C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\Theory_2025_01_16_prod.vdi" Exit Code: 0 Output: 2025-01-24 07:21:06 (17348): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2025_01_16_prod.vdi" Exit Code: 0 Output: UUID: 6a4110e9-e559-4c1c-bfd2-ba6f6aaf4169 Parent UUID: base State: created Type: normal (base) Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\Theory_2025_01_16_prod.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 781 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-01-24 07:21:07 (17348): Command: VBoxManage -q storageattach "boinc_432698a862acce62" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2025_01_16_prod.vdi" Exit Code: 0 Output: 2025-01-24 07:21:07 (17348): Command: VBoxManage -q storageattach "boinc_432698a862acce62" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none Exit Code: 0 Output: 2025-01-24 07:21:07 (17348): Command: VBoxManage -q storageattach "boinc_432698a862acce62" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2025_01_16_prod.vdi" Exit Code: 0 Output: 2025-01-24 07:21:07 (17348): Command: VBoxManage -q storageattach "boinc_432698a862acce62" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2025-01-24 07:21:08 (17348): Command: VBoxManage -q bandwidthctl "boinc_432698a862acce62" add "boinc_432698a862acce62_net" --type network --limit 1024G Exit Code: 0 Output: 2025-01-24 07:21:08 (17348): Command: VBoxManage -q modifyvm "boinc_432698a862acce62" --natpf1 ",tcp,127.0.0.1,61425,,80" Exit Code: 0 Output: 2025-01-24 07:21:08 (17348): Command: VBoxManage -q list extpacks Exit Code: 0 Output: Extension Packs: 1 Pack no. 0: Oracle VirtualBox Extension Pack Version: 7.1.0 Revision: 164728 Edition: Description: Oracle Cloud Infrastructure integration, Host Webcam, VirtualBox RDP, PXE ROM, Disk Encryption, NVMe, full VM encryption. VRDE Module: VBoxVRDP Crypto Module: VBoxPuelCrypto Usable: true Why unusable: 2025-01-24 07:21:08 (17348): Command: VBoxManage -q modifyvm "boinc_432698a862acce62" --vrde on --vrdeextpack default --vrdeauthlibrary default --vrdeauthtype null --vrdeport 61426 --vrde-property "Security/Method=RDP" Exit Code: 0 Output: 2025-01-24 07:21:09 (17348): Command: VBoxManage -q sharedfolder add "boinc_432698a862acce62" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\1/shared" Exit Code: 0 Output: 2025-01-24 07:21:10 (17348): Command: VBoxManage -q startvm "boinc_432698a862acce62" --type headless Exit Code: 1 Output: VBoxManage.exe: error: The virtual machine 'boinc_432698a862acce62' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\1\boinc_432698a862acce62\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_432698a862acce62" to power on... 2025-01-24 07:21:10 (17348): Command: VBoxManage -q snapshot "boinc_432698a862acce62" list Exit Code: -108 Output: This machine does not have any snapshots 2025-01-24 07:21:10 (17348): Command: VBoxManage -q bandwidthctl "boinc_432698a862acce62" remove "boinc_432698a862acce62_net" Exit Code: 0 Output: 2025-01-24 07:21:10 (17348): Command: VBoxManage -q unregistervm "boinc_432698a862acce62" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 2025-01-24 07:21:15 (17348): called boinc_finish(1) </stderr_txt> ]]>
©2025 CERN