Name | CMS_1901619_1737660033.260637_0 |
Workunit | 229915966 |
Created | 23 Jan 2025, 19:20:36 UTC |
Sent | 23 Jan 2025, 19:26:30 UTC |
Report deadline | 23 Feb 2025, 19:26:30 UTC |
Received | 23 Jan 2025, 19:27:32 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | -2147467259 (0x80004005) Unknown error code |
Computer ID | 10868297 |
Run time | 23 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 23.87 GFLOPS |
Application version | CMS Simulation v70.60 (vbox64_mt_mcore_cms) windows_x86_64 |
Peak working set size | 10.04 MB |
Peak swap size | 5.30 MB |
Peak disk usage | 0.76 MB |
<core_client_version>8.0.2</core_client_version> <![CDATA[ <message> Unbekannter Fehler (0x80004005) - exit code 2147500037 (0x80004005)</message> <stderr_txt> 2025-01-23 20:26:34 (5100): vboxwrapper version 26208 2025-01-23 20:26:34 (5100): BOINC client version: 8.0.2 2025-01-23 20:26:35 (5100): Detected: VirtualBox VboxManage Interface (Version: 7.1.4) 2025-01-23 20:26:35 (5100): Detected: Heartbeat check (file: 'heartbeat' every 1200.000000 seconds) 2025-01-23 20:26:35 (5100): Successfully copied 'init_data.xml' to the shared directory. 2025-01-23 20:26:35 (5100): Create VM. (boinc_0326488135664437, slot#0) 2025-01-23 20:26:36 (5100): Setting Memory Size for VM. (4584MB) 2025-01-23 20:26:36 (5100): Setting CPU Count for VM. (4) 2025-01-23 20:26:36 (5100): Setting Chipset Options for VM. 2025-01-23 20:26:37 (5100): Setting Graphics Controller Options for VM. 2025-01-23 20:26:37 (5100): Setting Boot Options for VM. 2025-01-23 20:26:37 (5100): Setting Network Configuration for NAT. 2025-01-23 20:26:38 (5100): Enabling VM Network Access. 2025-01-23 20:26:38 (5100): Disabling USB Support for VM. 2025-01-23 20:26:38 (5100): Disabling COM Port Support for VM. 2025-01-23 20:26:38 (5100): Disabling LPT Port Support for VM. 2025-01-23 20:26:39 (5100): Disabling Audio Support for VM. 2025-01-23 20:26:39 (5100): Disabling Clipboard Support for VM. 2025-01-23 20:26:39 (5100): Disabling Drag and Drop Support for VM. 2025-01-23 20:26:39 (5100): Adding storage controller(s) to VM. 2025-01-23 20:26:40 (5100): Adding virtual disk drive to VM. (CMS_2025_01_16_prod.vdi) 2025-01-23 20:26:41 (5100): Adding VirtualBox Guest Additions to VM. 2025-01-23 20:26:41 (5100): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2025-01-23 20:26:41 (5100): forwarding host port 50257 to guest port 80 2025-01-23 20:26:41 (5100): Enabling remote desktop for VM. 2025-01-23 20:26:42 (5100): Required extension pack not installed, remote desktop not enabled. 2025-01-23 20:26:42 (5100): Enabling shared directory for VM. 2025-01-23 20:26:42 (5100): Starting VM using VBoxManage interface. (boinc_0326488135664437, slot#0) 2025-01-23 20:26:45 (5100): Error in start VM for VM: -2147467259 Command: VBoxManage -q startvm "boinc_0326488135664437" --type headless Output: VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole Waiting for VM "boinc_0326488135664437" to power on... 2025-01-23 20:26:45 (5100): VM failed to start. 2025-01-23 20:26:45 (5100): Could not start 2025-01-23 20:26:45 (5100): ERROR: VM failed to start 2025-01-23 20:26:45 (5100): Powering off VM. 2025-01-23 20:26:45 (5100): Deregistering VM. (boinc_0326488135664437, slot#0) 2025-01-23 20:26:45 (5100): Removing network bandwidth throttle group from VM. 2025-01-23 20:26:45 (5100): Removing VM from VirtualBox. Hypervisor System Log: 00:01:29.002546 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5bfd8965-b81b-469f-8649-f717ce97a5d5} aComponent={NvramStoreWrap} aText={The UEFI NVRAM file is not existing for this machine}, preserve=false aResultDetail=0 00:01:29.003714 ERROR [COM]: aRC=VBOX_E_INVALID_VM_STATE (0x80bb0002) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={MachineWrap} aText={The machine is not mutable, saved or running (state is PoweredOff)}, preserve=false aResultDetail=0 00:01:29.204093 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_c60a403a220074d4\boinc_c60a403a220074d4.vbox" with version "1.19-windows" 00:01:29.205705 Finished saving settings file "C:\ProgramData\BOINC\slots\2\boinc_c60a403a220074d4\boinc_c60a403a220074d4.vbox" 00:01:29.208848 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5bfd8965-b81b-469f-8649-f717ce97a5d5} aComponent={NvramStoreWrap} aText={The UEFI NVRAM file is not existing for this machine}, preserve=false aResultDetail=0 00:01:29.210014 ERROR [COM]: aRC=VBOX_E_INVALID_VM_STATE (0x80bb0002) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={MachineWrap} aText={The machine is not mutable, saved or running (state is PoweredOff)}, preserve=false aResultDetail=0 00:01:29.233943 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:01:29.510258 Saving settings file "C:\Users\Danie\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:01:29.511690 Finished saving settings file "C:\Users\Danie\.VirtualBox\VirtualBox.xml" 00:01:29.511792 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_258d0490bd3fe53f\boinc_258d0490bd3fe53f.vbox" with version "1.19-windows" 00:01:29.513140 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_258d0490bd3fe53f\boinc_258d0490bd3fe53f.vbox" 00:01:29.513561 DeleteVM Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_258d0490bd3fe53f\boinc_258d0490bd3fe53f.vbox" with version "1.19-windows" 00:01:29.514825 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={d644ad1e-c501-4fc7-9ab6-aa6d763bc540} aComponent={VirtualBoxWrap} aText={Could not find a registered machine with UUID {d72d41cd-8b60-4204-881a-6d5862cb5809}}, preserve=false aResultDetail=0 00:01:29.515888 DeleteVM Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_258d0490bd3fe53f\boinc_258d0490bd3fe53f.vbox" 00:01:29.518022 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={d644ad1e-c501-4fc7-9ab6-aa6d763bc540} aComponent={VirtualBoxWrap} aText={Could not find a registered machine with UUID {d72d41cd-8b60-4204-881a-6d5862cb5809}}, preserve=false aResultDetail=0 00:01:29.522688 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5bfd8965-b81b-469f-8649-f717ce97a5d5} aComponent={NvramStoreWrap} aText={The UEFI NVRAM file is not existing for this machine}, preserve=false aResultDetail=0 00:01:29.524128 ERROR [COM]: aRC=VBOX_E_INVALID_VM_STATE (0x80bb0002) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={MachineWrap} aText={The machine is not mutable, saved or running (state is PoweredOff)}, preserve=false aResultDetail=0 00:01:30.013558 Platform architecture set to 'x86' 00:01:30.056403 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5bfd8965-b81b-469f-8649-f717ce97a5d5} aComponent={NvramStoreWrap} aText={The UEFI NVRAM file is not existing for this machine}, preserve=false aResultDetail=0 00:01:30.060234 ERROR [COM]: aRC=VBOX_E_INVALID_VM_STATE (0x80bb0002) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={MachineWrap} aText={The machine is not mutable, saved or running (state is PoweredOff)}, preserve=false aResultDetail=0 00:01:30.110002 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5bfd8965-b81b-469f-8649-f717ce97a5d5} aComponent={NvramStoreWrap} aText={The UEFI NVRAM file is not existing for this machine}, preserve=false aResultDetail=0 00:01:30.115708 ERROR [COM]: aRC=VBOX_E_INVALID_VM_STATE (0x80bb0002) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={MachineWrap} aText={The machine is not mutable, saved or running (state is Starting)}, preserve=false aResultDetail=0 00:01:30.462275 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_258d0490bd3fe53f\boinc_258d0490bd3fe53f.vbox" with version "1.19-windows" 00:01:30.463642 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_258d0490bd3fe53f\boinc_258d0490bd3fe53f.vbox" 00:01:30.479972 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5bfd8965-b81b-469f-8649-f717ce97a5d5} aComponent={NvramStoreWrap} aText={The UEFI NVRAM file is not existing for this machine}, preserve=false aResultDetail=0 00:01:30.487247 ERROR [COM]: aRC=VBOX_E_INVALID_VM_STATE (0x80bb0002) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={MachineWrap} aText={The machine is not mutable, saved or running (state is PoweredOff)}, preserve=false aResultDetail=0 00:01:30.493607 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:01:30.625434 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5bfd8965-b81b-469f-8649-f717ce97a5d5} aComponent={NvramStoreWrap} aText={The UEFI NVRAM file is not existing for this machine}, preserve=false aResultDetail=0 00:01:30.641855 ERROR [COM]: aRC=VBOX_E_INVALID_VM_STATE (0x80bb0002) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={MachineWrap} aText={The machine is not mutable, saved or running (state is PoweredOff)}, preserve=false aResultDetail=0 00:01:30.787000 Saving settings file "C:\Users\Danie\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:01:30.788470 Finished saving settings file "C:\Users\Danie\.VirtualBox\VirtualBox.xml" 00:01:30.788511 Saving settings file "C:\Users\Danie\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:01:30.789785 Finished saving settings file "C:\Users\Danie\.VirtualBox\VirtualBox.xml" 00:01:30.790266 DeleteVM Saving settings file "C:\Users\Danie\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:01:30.792354 DeleteVM Finished saving settings file "C:\Users\Danie\.VirtualBox\VirtualBox.xml" 00:01:30.792404 Saving settings file "C:\Users\Danie\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:01:30.793954 Finished saving settings file "C:\Users\Danie\.VirtualBox\VirtualBox.xml" 00:01:30.796129 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={d644ad1e-c501-4fc7-9ab6-aa6d763bc540} aComponent={VirtualBoxWrap} aText={Could not find a registered machine with UUID {2ed1a659-8aa5-43b7-86e6-e6d922cf8732}}, preserve=false aResultDetail=0 00:01:30.799673 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={d644ad1e-c501-4fc7-9ab6-aa6d763bc540} aComponent={VirtualBoxWrap} aText={Could not find a registered machine with UUID {2ed1a659-8aa5-43b7-86e6-e6d922cf8732}}, preserve=false aResultDetail=0 00:01:30.807616 NvramStore: Loading 'TpmEmuTpms/permall' from archive 00:01:30.807657 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5bfd8965-b81b-469f-8649-f717ce97a5d5} aComponent={NvramStoreWrap} aText={The UEFI NVRAM file is not existing for this machine}, preserve=false aResultDetail=0 00:01:30.811810 ERROR [COM]: aRC=VBOX_E_INVALID_VM_STATE (0x80bb0002) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={MachineWrap} aText={The machine is not mutable, saved or running (state is PoweredOff)}, preserve=false aResultDetail=0 VM Execution Log: VM Startup Log: VM Trace Log: Gen Intel(R) Core(TM) i9-12900K Processor#7 speed: unknown Processor#7 description: 12th Gen Intel(R) Core(TM) i9-12900K Processor#8 speed: unknown Processor#8 description: 12th Gen Intel(R) Core(TM) i9-12900K Processor#9 speed: unknown Processor#9 description: 12th Gen Intel(R) Core(TM) i9-12900K Processor#10 speed: unknown Processor#10 description: 12th Gen Intel(R) Core(TM) i9-12900K Processor#11 speed: unknown Processor#11 description: 12th Gen Intel(R) Core(TM) i9-12900K Processor#12 speed: unknown Processor#12 description: 12th Gen Intel(R) Core(TM) i9-12900K Processor#13 speed: unknown Processor#13 description: 12th Gen Intel(R) Core(TM) i9-12900K Processor#14 speed: unknown Processor#14 description: 12th Gen Intel(R) Core(TM) i9-12900K Processor#15 speed: unknown Processor#15 description: 12th Gen Intel(R) Core(TM) i9-12900K Processor#16 speed: unknown Processor#16 description: 12th Gen Intel(R) Core(TM) i9-12900K Processor#17 speed: unknown Processor#17 description: 12th Gen Intel(R) Core(TM) i9-12900K Processor#18 speed: unknown Processor#18 description: 12th Gen Intel(R) Core(TM) i9-12900K Processor#19 speed: unknown Processor#19 description: 12th Gen Intel(R) Core(TM) i9-12900K Processor#20 speed: unknown Processor#20 description: 12th Gen Intel(R) Core(TM) i9-12900K Processor#21 speed: unknown Processor#21 description: 12th Gen Intel(R) Core(TM) i9-12900K Processor#22 speed: unknown Processor#22 description: 12th Gen Intel(R) Core(TM) i9-12900K Processor#23 speed: unknown Processor#23 description: 12th Gen Intel(R) Core(TM) i9-12900K Memory size: 32509 MByte Memory available: 25417 MByte Operating system: Windows 11 Operating system version: 10.0.22631 2025-01-23 20:26:35 (5100): Command: VBoxManage -q showvminfo "boinc_0326488135664437" --machinereadable Exit Code: -2135228415 Output: VBoxManage.exe: error: Could not find a registered machine named 'boinc_0326488135664437' VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 3212 of file VBoxManageInfo.cpp 2025-01-23 20:26:36 (5100): Command: VBoxManage -q createvm --name "boinc_0326488135664437" --basefolder "C:\ProgramData\BOINC\slots\0" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_0326488135664437' is created and registered. UUID: 24d36b78-7484-4603-8671-39f3fce1e87a Settings file: 'C:\ProgramData\BOINC\slots\0\boinc_0326488135664437\boinc_0326488135664437.vbox' 2025-01-23 20:26:36 (5100): Command: VBoxManage -q modifyvm "boinc_0326488135664437" --description "CMS_1901619_1737660033.260637_0" Exit Code: 0 Output: 2025-01-23 20:26:36 (5100): Command: VBoxManage -q modifyvm "boinc_0326488135664437" --memory 4584 Exit Code: 0 Output: 2025-01-23 20:26:36 (5100): Command: VBoxManage -q modifyvm "boinc_0326488135664437" --cpus 4 Exit Code: 0 Output: 2025-01-23 20:26:37 (5100): Command: VBoxManage -q modifyvm "boinc_0326488135664437" --acpi on --ioapic on --rtcuseutc off Exit Code: 0 Output: 2025-01-23 20:26:37 (5100): Command: VBoxManage -q modifyvm "boinc_0326488135664437" --vram 16 --graphicscontroller VBoxVGA Exit Code: 0 Output: 2025-01-23 20:26:37 (5100): Command: VBoxManage -q modifyvm "boinc_0326488135664437" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2025-01-23 20:26:38 (5100): Command: VBoxManage -q modifyvm "boinc_0326488135664437" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2025-01-23 20:26:38 (5100): Command: VBoxManage -q modifyvm "boinc_0326488135664437" --cableconnected1 on Exit Code: 0 Output: 2025-01-23 20:26:38 (5100): Command: VBoxManage -q modifyvm "boinc_0326488135664437" --usb off Exit Code: 0 Output: 2025-01-23 20:26:38 (5100): Command: VBoxManage -q modifyvm "boinc_0326488135664437" --uart1 off --uart2 off Exit Code: 0 Output: 2025-01-23 20:26:39 (5100): Command: VBoxManage -q modifyvm "boinc_0326488135664437" --lpt1 off --lpt2 off Exit Code: 0 Output: 2025-01-23 20:26:39 (5100): Command: VBoxManage -q modifyvm "boinc_0326488135664437" --audio-enabled off Exit Code: 0 Output: 2025-01-23 20:26:39 (5100): Command: VBoxManage -q modifyvm "boinc_0326488135664437" --clipboard disabled Exit Code: 0 Output: 2025-01-23 20:26:39 (5100): Command: VBoxManage -q modifyvm "boinc_0326488135664437" --draganddrop disabled Exit Code: 0 Output: 2025-01-23 20:26:40 (5100): Command: VBoxManage -q storagectl "boinc_0326488135664437" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2025-01-23 20:26:40 (5100): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2025_01_16_prod.vdi" Exit Code: 0 Output: UUID: 3da9ab36-1206-4cc3-8a9a-8d4138ab45c5 Parent UUID: base State: created Type: normal (base) Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\CMS_2025_01_16_prod.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 3853 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-01-23 20:26:40 (5100): Command: VBoxManage -q storageattach "boinc_0326488135664437" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2025_01_16_prod.vdi" Exit Code: 0 Output: 2025-01-23 20:26:40 (5100): Command: VBoxManage -q storageattach "boinc_0326488135664437" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none Exit Code: 0 Output: 2025-01-23 20:26:41 (5100): Command: VBoxManage -q storageattach "boinc_0326488135664437" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2025_01_16_prod.vdi" Exit Code: 0 Output: 2025-01-23 20:26:41 (5100): Command: VBoxManage -q storageattach "boinc_0326488135664437" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2025-01-23 20:26:41 (5100): Command: VBoxManage -q bandwidthctl "boinc_0326488135664437" add "boinc_0326488135664437_net" --type network --limit 1024G Exit Code: 0 Output: 2025-01-23 20:26:41 (5100): Command: VBoxManage -q modifyvm "boinc_0326488135664437" --natpf1 ",tcp,127.0.0.1,50257,,80" Exit Code: 0 Output: 2025-01-23 20:26:42 (5100): Command: VBoxManage -q list extpacks Exit Code: 0 Output: Extension Packs: 0 2025-01-23 20:26:42 (5100): Command: VBoxManage -q sharedfolder add "boinc_0326488135664437" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\0/shared" Exit Code: 0 Output: 2025-01-23 20:26:45 (5100): Command: VBoxManage -q startvm "boinc_0326488135664437" --type headless Exit Code: -2147467259 Output: VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole Waiting for VM "boinc_0326488135664437" to power on... 2025-01-23 20:26:45 (5100): Command: VBoxManage -q snapshot "boinc_0326488135664437" list Exit Code: -108 Output: This machine does not have any snapshots 2025-01-23 20:26:45 (5100): Command: VBoxManage -q bandwidthctl "boinc_0326488135664437" remove "boinc_0326488135664437_net" Exit Code: 0 Output: VBoxManage.exe: error: Bandwidth groups cannot be deleted while the VM is running 2025-01-23 20:26:46 (5100): Command: VBoxManage -q unregistervm "boinc_0326488135664437" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 2025-01-23 20:26:56 (5100): called boinc_finish(-2147467259) </stderr_txt> ]]>
©2025 CERN