Name Theory_2773-2974544-232_1
Workunit 229795930
Created 23 Jan 2025, 18:14:00 UTC
Sent 23 Jan 2025, 18:14:17 UTC
Report deadline 3 Feb 2025, 18:14:17 UTC
Received 23 Jan 2025, 20:32:52 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status -2147467259 (0x80004005) Unknown error code
Computer ID 10856670
Run time 8 sec
CPU time
Validate state Invalid
Credit 0.00
Device peak FLOPS 4.22 GFLOPS
Application version Theory Simulation v300.60 (vbox64_theory)
windows_x86_64
Peak working set size 11.83 MB
Peak swap size 6.24 MB
Peak disk usage 1.01 MB

Stderr output

<core_client_version>8.0.2</core_client_version>
<![CDATA[
<message>
Unspecified error
 (0x80004005) - exit code 2147500037 (0x80004005)</message>
<stderr_txt>
2025-01-23 11:21:39 (18728): vboxwrapper version 26208
2025-01-23 11:21:39 (18728): BOINC client version: 8.0.2
2025-01-23 11:21:39 (18728): Detected: VirtualBox VboxManage Interface (Version: 7.0.6)
2025-01-23 11:21:40 (18728): Detected: Heartbeat check (file: 'heartbeat' every 1200.000000 seconds)
2025-01-23 11:21:40 (18728): Successfully copied 'init_data.xml' to the shared directory.
2025-01-23 11:21:40 (18728): Successfully copied 'input' to the shared directory.
2025-01-23 11:21:40 (18728): Create VM. (boinc_f838571ef3ba3d99, slot#10)
2025-01-23 11:21:41 (18728): Setting Memory Size for VM. (630MB)
2025-01-23 11:21:41 (18728): Setting CPU Count for VM. (1)
2025-01-23 11:21:42 (18728): Setting Chipset Options for VM.
2025-01-23 11:21:42 (18728): Setting Graphics Controller Options for VM.
2025-01-23 11:21:42 (18728): Setting Boot Options for VM.
2025-01-23 11:21:43 (18728): Setting Network Configuration for NAT.
2025-01-23 11:21:43 (18728): Enabling VM Network Access.
2025-01-23 11:21:43 (18728): Disabling USB Support for VM.
2025-01-23 11:21:43 (18728): Disabling COM Port Support for VM.
2025-01-23 11:21:44 (18728): Disabling LPT Port Support for VM.
2025-01-23 11:21:44 (18728): Disabling Audio Support for VM.
2025-01-23 11:21:44 (18728): Disabling Clipboard Support for VM.
2025-01-23 11:21:45 (18728): Disabling Drag and Drop Support for VM.
2025-01-23 11:21:45 (18728): Adding storage controller(s) to VM.
2025-01-23 11:21:45 (18728): Adding virtual disk drive to VM. (Theory_2025_01_16_prod.vdi)
2025-01-23 11:21:48 (18728): Attempts: 2
2025-01-23 11:21:48 (18728): Adding VirtualBox Guest Additions to VM.
2025-01-23 11:21:49 (18728): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2025-01-23 11:21:49 (18728): forwarding host port 53814 to guest port 80
2025-01-23 11:21:49 (18728): Enabling remote desktop for VM.
2025-01-23 11:21:50 (18728): Required extension pack not installed, remote desktop not enabled.
2025-01-23 11:21:50 (18728): Enabling shared directory for VM.
2025-01-23 11:21:50 (18728): Starting VM using VBoxManage interface. (boinc_f838571ef3ba3d99, slot#10)
2025-01-23 11:21:54 (18728): Error in start VM for VM: -2147467259
Command:
VBoxManage -q startvm "boinc_f838571ef3ba3d99" --type headless
Output:
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: AMD-V is disabled in the BIOS (or by the host OS) (VERR_SVM_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole
Waiting for VM "boinc_f838571ef3ba3d99" to power on...

2025-01-23 11:21:54 (18728): VM failed to start.
2025-01-23 11:21:54 (18728): Could not start 
2025-01-23 11:21:54 (18728): ERROR: VM failed to start
2025-01-23 11:21:54 (18728): Powering off VM.
2025-01-23 11:21:54 (18728): Deregistering VM. (boinc_f838571ef3ba3d99, slot#10)
2025-01-23 11:21:55 (18728): Removing network bandwidth throttle group from VM.
2025-01-23 11:21:55 (18728): Removing VM from VirtualBox.

    Hypervisor System Log:

42:19:18.531981          Launched VM: 70871488 pid: 5076 (0x13d4) frontend: headless name: boinc_85dcc52a58f21123
42:19:18.622667          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_453ba937c1fc9c40\boinc_453ba937c1fc9c40.vbox" with version "1.19-windows"
42:19:18.628590          Finished saving settings file "C:\ProgramData\BOINC\slots\2\boinc_453ba937c1fc9c40\boinc_453ba937c1fc9c40.vbox"
42:19:18.804140          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
42:19:18.931121          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_453ba937c1fc9c40\boinc_453ba937c1fc9c40.vbox" with version "1.19-windows"
42:19:18.936353          Finished saving settings file "C:\ProgramData\BOINC\slots\2\boinc_453ba937c1fc9c40\boinc_453ba937c1fc9c40.vbox"
42:19:19.216295          Saving settings file "C:\Users\MikeReed\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
42:19:19.221485          Finished saving settings file "C:\Users\MikeReed\.VirtualBox\VirtualBox.xml"
42:19:19.222723 DeleteVM Saving settings file "C:\ProgramData\BOINC\slots\17\boinc_e8d31ede2f4f8571\boinc_e8d31ede2f4f8571.vbox" with version "1.19-windows"
42:19:19.229218 DeleteVM Finished saving settings file "C:\ProgramData\BOINC\slots\17\boinc_e8d31ede2f4f8571\boinc_e8d31ede2f4f8571.vbox"
42:19:19.282625          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_5191959c6b3e4610\boinc_5191959c6b3e4610.vbox" with version "1.19-windows"
42:19:19.288379          Finished saving settings file "C:\ProgramData\BOINC\slots\3\boinc_5191959c6b3e4610\boinc_5191959c6b3e4610.vbox"
42:19:19.445670          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
42:19:19.576373          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_5191959c6b3e4610\boinc_5191959c6b3e4610.vbox" with version "1.19-windows"
42:19:19.581712          Finished saving settings file "C:\ProgramData\BOINC\slots\3\boinc_5191959c6b3e4610\boinc_5191959c6b3e4610.vbox"
42:19:19.854739          Saving settings file "C:\Users\MikeReed\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
42:19:19.862324          Finished saving settings file "C:\Users\MikeReed\.VirtualBox\VirtualBox.xml"
42:19:19.863768 DeleteVM Saving settings file "C:\ProgramData\BOINC\slots\17\boinc_e8d31ede2f4f8571\boinc_e8d31ede2f4f8571.vbox" with version "1.19-windows"
42:19:19.869633 DeleteVM Finished saving settings file "C:\ProgramData\BOINC\slots\17\boinc_e8d31ede2f4f8571\boinc_e8d31ede2f4f8571.vbox"
42:19:19.960100          Saving settings file "C:\ProgramData\BOINC\slots\10\boinc_f838571ef3ba3d99\boinc_f838571ef3ba3d99.vbox" with version "1.19-windows"
42:19:19.965236          Finished saving settings file "C:\ProgramData\BOINC\slots\10\boinc_f838571ef3ba3d99\boinc_f838571ef3ba3d99.vbox"
42:19:20.121512          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
42:19:20.261974          Saving settings file "C:\ProgramData\BOINC\slots\10\boinc_f838571ef3ba3d99\boinc_f838571ef3ba3d99.vbox" with version "1.19-windows"
42:19:20.267232          Finished saving settings file "C:\ProgramData\BOINC\slots\10\boinc_f838571ef3ba3d99\boinc_f838571ef3ba3d99.vbox"
42:19:20.529838          Saving settings file "C:\Users\MikeReed\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
42:19:20.534582          Finished saving settings file "C:\Users\MikeReed\.VirtualBox\VirtualBox.xml"
42:19:20.535777 DeleteVM Saving settings file "C:\ProgramData\BOINC\slots\17\boinc_e8d31ede2f4f8571\boinc_e8d31ede2f4f8571.vbox" with version "1.19-windows"
42:19:20.541991 DeleteVM Finished saving settings file "C:\ProgramData\BOINC\slots\17\boinc_e8d31ede2f4f8571\boinc_e8d31ede2f4f8571.vbox"
42:19:20.838732          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_12f403f75e549300\boinc_12f403f75e549300.vbox" with version "1.19-windows"
42:19:20.844166          Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_12f403f75e549300\boinc_12f403f75e549300.vbox"
42:19:21.000664          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
42:19:21.145795          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_12f403f75e549300\boinc_12f403f75e549300.vbox" with version "1.19-windows"
42:19:21.151259          Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_12f403f75e549300\boinc_12f403f75e549300.vbox"
42:19:21.435733          Saving settings file "C:\Users\MikeReed\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
42:19:21.442991          Finished saving settings file "C:\Users\MikeReed\.VirtualBox\VirtualBox.xml"
42:19:21.444166 DeleteVM Saving settings file "C:\ProgramData\BOINC\slots\17\boinc_e8d31ede2f4f8571\boinc_e8d31ede2f4f8571.vbox" with version "1.19-windows"
42:19:21.450101 DeleteVM Finished saving settings file "C:\ProgramData\BOINC\slots\17\boinc_e8d31ede2f4f8571\boinc_e8d31ede2f4f8571.vbox"
42:19:21.470838          Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_85324d6795b743d1\boinc_85324d6795b743d1.vbox" with version "1.19-windows"
42:19:21.476016          Finished saving settings file "C:\ProgramData\BOINC\slots\4\boinc_85324d6795b743d1\boinc_85324d6795b743d1.vbox"
42:19:21.622389          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
42:19:21.759088          Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_85324d6795b743d1\boinc_85324d6795b743d1.vbox" with version "1.19-windows"
42:19:21.766905          Finished saving settings file "C:\ProgramData\BOINC\slots\4\boinc_85324d6795b743d1\boinc_85324d6795b743d1.vbox"
42:19:22.014427          Saving settings file "C:\Users\MikeReed\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
42:19:22.021969          Finished saving settings file "C:\Users\MikeReed\.VirtualBox\VirtualBox.xml"
42:19:22.023231 DeleteVM Saving settings file "C:\ProgramData\BOINC\slots\17\boinc_e8d31ede2f4f8571\boinc_e8d31ede2f4f8571.vbox" with version "1.19-windows"
42:19:22.028882 DeleteVM Finished saving settings file "C:\ProgramData\BOINC\slots\17\boinc_e8d31ede2f4f8571\boinc_e8d31ede2f4f8571.vbox"
42:19:22.378941          Saving settings file "C:\ProgramData\BOINC\slots\6\boinc_85dcc52a58f21123\boinc_85dcc52a58f21123.vbox" with version "1.19-windows"
42:19:22.389139          Finished saving settings file "C:\ProgramData\BOINC\slots\6\boinc_85dcc52a58f21123\boinc_85dcc52a58f21123.vbox"
42:19:22.519940          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
42:19:22.635486          Saving settings file "C:\ProgramData\BOINC\slots\6\boinc_85dcc52a58f21123\boinc_85dcc52a58f21123.vbox" with version "1.19-windows"
42:19:22.643550          Finished saving settings file "C:\ProgramData\BOINC\slots\6\boinc_85dcc52a58f21123\boinc_85dcc52a58f21123.vbox"
42:19:22.901408          Saving settings file "C:\Users\MikeReed\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
42:19:22.905948          Finished saving settings file "C:\Users\MikeReed\.VirtualBox\VirtualBox.xml"
42:19:22.907026 DeleteVM Saving settings file "C:\ProgramData\BOINC\slots\17\boinc_e8d31ede2f4f8571\boinc_e8d31ede2f4f8571.vbox" with version "1.19-windows"
42:19:22.912538 DeleteVM Finished saving settings file "C:\ProgramData\BOINC\slots\17\boinc_e8d31ede2f4f8571\boinc_e8d31ede2f4f8571.vbox"

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

   
Default Guest Additions ISO:     C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso
Logging Level:                   all
Proxy Mode:                      System
Proxy URL:                       
User language:                   C

2025-01-23 11:21:40 (18728): 
Command: VBoxManage -q list hostinfo 
Exit Code: 0
Output:
Host Information:

Host time: 2025-01-23T18:21:40.181000000Z
Processor online count: 12
Processor count: 12
Processor online core count: 6
Processor core count: 6
Processor supports HW virtualization: no
Processor supports PAE: yes
Processor supports long mode: yes
Processor supports nested paging: no
Processor supports unrestricted guest: no
Processor supports nested HW virtualization: no
Processor supports virt. vmsave/vmload: no
Processor#0 speed: unknown
Processor#0 description: AMD Ryzen 5 1600 Six-Core Processor
Processor#1 speed: unknown
Processor#1 description: AMD Ryzen 5 1600 Six-Core Processor
Processor#2 speed: unknown
Processor#2 description: AMD Ryzen 5 1600 Six-Core Processor
Processor#3 speed: unknown
Processor#3 description: AMD Ryzen 5 1600 Six-Core Processor
Processor#4 speed: unknown
Processor#4 description: AMD Ryzen 5 1600 Six-Core Processor
Processor#5 speed: unknown
Processor#5 description: AMD Ryzen 5 1600 Six-Core Processor
Processor#6 speed: unknown
Processor#6 description: AMD Ryzen 5 1600 Six-Core Processor
Processor#7 speed: unknown
Processor#7 description: AMD Ryzen 5 1600 Six-Core Processor
Processor#8 speed: unknown
Processor#8 description: AMD Ryzen 5 1600 Six-Core Processor
Processor#9 speed: unknown
Processor#9 description: AMD Ryzen 5 1600 Six-Core Processor
Processor#10 speed: unknown
Processor#10 description: AMD Ryzen 5 1600 Six-Core Processor
Processor#11 speed: unknown
Processor#11 description: AMD Ryzen 5 1600 Six-Core Processor
Memory size: 16335 MByte
Memory available: 5963 MByte
Operating system: Windows 10
Operating system version: 10.0.19045

2025-01-23 11:21:40 (18728): 
Command: VBoxManage -q showvminfo "boinc_f838571ef3ba3d99" --machinereadable 
Exit Code: -2135228415
Output:
VBoxManage.exe: error: Could not find a registered machine named 'boinc_f838571ef3ba3d99'
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown
VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 3139 of file VBoxManageInfo.cpp

2025-01-23 11:21:41 (18728): 
Command: VBoxManage -q createvm --name "boinc_f838571ef3ba3d99" --basefolder "C:\ProgramData\BOINC\slots\10" --ostype "Linux26_64" --register
Exit Code: 0
Output:
Virtual machine 'boinc_f838571ef3ba3d99' is created and registered.
UUID: 7a07f23c-97cc-46e4-9e4b-43db0b449dd1
Settings file: 'C:\ProgramData\BOINC\slots\10\boinc_f838571ef3ba3d99\boinc_f838571ef3ba3d99.vbox'

2025-01-23 11:21:41 (18728): 
Command: VBoxManage -q modifyvm "boinc_f838571ef3ba3d99" --description "Theory_2773-2974544-232_1" 
Exit Code: 0
Output:

2025-01-23 11:21:41 (18728): 
Command: VBoxManage -q modifyvm "boinc_f838571ef3ba3d99" --memory 630 
Exit Code: 0
Output:

2025-01-23 11:21:42 (18728): 
Command: VBoxManage -q modifyvm "boinc_f838571ef3ba3d99" --cpus 1 
Exit Code: 0
Output:

2025-01-23 11:21:42 (18728): 
Command: VBoxManage -q modifyvm "boinc_f838571ef3ba3d99" --acpi on --ioapic on --rtcuseutc off 
Exit Code: 0
Output:

2025-01-23 11:21:42 (18728): 
Command: VBoxManage -q modifyvm "boinc_f838571ef3ba3d99" --vram 16 --graphicscontroller VBoxVGA 
Exit Code: 0
Output:

2025-01-23 11:21:43 (18728): 
Command: VBoxManage -q modifyvm "boinc_f838571ef3ba3d99" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2025-01-23 11:21:43 (18728): 
Command: VBoxManage -q modifyvm "boinc_f838571ef3ba3d99" --nic1 nat --natdnsproxy1 on --cableconnected1 off 
Exit Code: 0
Output:

2025-01-23 11:21:43 (18728): 
Command: VBoxManage -q modifyvm "boinc_f838571ef3ba3d99" --cableconnected1 on 
Exit Code: 0
Output:

2025-01-23 11:21:43 (18728): 
Command: VBoxManage -q modifyvm "boinc_f838571ef3ba3d99" --usb off 
Exit Code: 0
Output:

2025-01-23 11:21:44 (18728): 
Command: VBoxManage -q modifyvm "boinc_f838571ef3ba3d99" --uart1 off --uart2 off 
Exit Code: 0
Output:

2025-01-23 11:21:44 (18728): 
Command: VBoxManage -q modifyvm "boinc_f838571ef3ba3d99" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2025-01-23 11:21:44 (18728): 
Command: VBoxManage -q modifyvm "boinc_f838571ef3ba3d99" --audio-enabled off 
Exit Code: 0
Output:

2025-01-23 11:21:45 (18728): 
Command: VBoxManage -q modifyvm "boinc_f838571ef3ba3d99" --clipboard disabled 
Exit Code: 0
Output:

2025-01-23 11:21:45 (18728): 
Command: VBoxManage -q modifyvm "boinc_f838571ef3ba3d99" --draganddrop disabled 
Exit Code: 0
Output:

2025-01-23 11:21:45 (18728): 
Command: VBoxManage -q storagectl "boinc_f838571ef3ba3d99" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2025-01-23 11:21:48 (18728): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2025_01_16_prod.vdi" 
Exit Code: 0
Output:
UUID:           6a4110e9-e559-4c1c-bfd2-ba6f6aaf4169
Parent UUID:    base
State:          locked read
Type:           multiattach
Location:       C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\Theory_2025_01_16_prod.vdi
Storage format: VDI
Format variant: dynamic default
Capacity:       20480 MBytes
Size on disk:   781 MBytes
Encryption:     disabled
Property:       AllocationBlockSize=1048576
Child UUIDs:    93876766-8046-461b-9305-e59f89dfc2a6
                3984e011-5e07-4970-89b4-ce8ccee5cc8f
                26088678-e715-4351-8981-cedb18108126
                13695649-5a65-46ea-9146-826f5e2cd430
                d72c66a8-fdb3-479a-9791-a20ac177f36b

2025-01-23 11:21:48 (18728): 
Command: VBoxManage -q storageattach "boinc_f838571ef3ba3d99" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2025_01_16_prod.vdi" 
Exit Code: 0
Output:

2025-01-23 11:21:49 (18728): 
Command: VBoxManage -q storageattach "boinc_f838571ef3ba3d99" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2025-01-23 11:21:49 (18728): 
Command: VBoxManage -q bandwidthctl "boinc_f838571ef3ba3d99" add "boinc_f838571ef3ba3d99_net" --type network --limit 1024G 
Exit Code: 0
Output:

2025-01-23 11:21:49 (18728): 
Command: VBoxManage -q modifyvm "boinc_f838571ef3ba3d99" --natpf1 ",tcp,127.0.0.1,53814,,80" 
Exit Code: 0
Output:

2025-01-23 11:21:50 (18728): 
Command: VBoxManage -q list extpacks
Exit Code: 0
Output:
Extension Packs: 0

2025-01-23 11:21:50 (18728): 
Command: VBoxManage -q sharedfolder add "boinc_f838571ef3ba3d99" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\10/shared"
Exit Code: 0
Output:

2025-01-23 11:21:54 (18728): 
Command: VBoxManage -q startvm "boinc_f838571ef3ba3d99" --type headless
Exit Code: -2147467259
Output:
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: AMD-V is disabled in the BIOS (or by the host OS) (VERR_SVM_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole
Waiting for VM "boinc_f838571ef3ba3d99" to power on...

2025-01-23 11:21:55 (18728): 
Command: VBoxManage -q snapshot "boinc_f838571ef3ba3d99" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2025-01-23 11:21:55 (18728): 
Command: VBoxManage -q bandwidthctl "boinc_f838571ef3ba3d99" remove "boinc_f838571ef3ba3d99_net" 
Exit Code: 0
Output:

2025-01-23 11:21:55 (18728): 
Command: VBoxManage -q unregistervm "boinc_f838571ef3ba3d99" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

2025-01-23 11:22:05 (18728): called boinc_finish(-2147467259)

</stderr_txt>
]]>


©2025 CERN