Name | CMS_1772211_1737607186.193568_0 |
Workunit | 229906621 |
Created | 23 Jan 2025, 4:39:50 UTC |
Sent | 23 Jan 2025, 5:07:09 UTC |
Report deadline | 23 Feb 2025, 5:07:09 UTC |
Received | 23 Jan 2025, 5:18:32 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | 1 (0x00000001) Unknown error code |
Computer ID | 10834640 |
Run time | |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 21.57 GFLOPS |
Application version | CMS Simulation v70.60 (vbox64_mt_mcore_cms) windows_x86_64 |
Peak working set size | 7.27 MB |
Peak swap size | 1.79 MB |
<core_client_version>8.0.2</core_client_version> <![CDATA[ <message> Incorrect function. (0x1) - exit code 1 (0x1)</message> <stderr_txt> 2025-01-23 00:13:47 (26300): vboxwrapper version 26208 2025-01-23 00:13:47 (26300): BOINC client version: 8.0.2 2025-01-23 00:13:48 (26300): Detected: VirtualBox VboxManage Interface (Version: 7.0.12) 2025-01-23 00:13:48 (26300): Detected: Heartbeat check (file: 'heartbeat' every 1200.000000 seconds) 2025-01-23 00:13:48 (26300): Successfully copied 'init_data.xml' to the shared directory. 2025-01-23 00:13:48 (26300): Create VM. (boinc_a154f736f754b3d8, slot#7) 2025-01-23 00:13:49 (26300): Setting Memory Size for VM. (4584MB) 2025-01-23 00:13:49 (26300): Setting CPU Count for VM. (4) 2025-01-23 00:13:49 (26300): Setting Chipset Options for VM. 2025-01-23 00:13:49 (26300): Setting Graphics Controller Options for VM. 2025-01-23 00:13:50 (26300): Setting Boot Options for VM. 2025-01-23 00:13:50 (26300): Setting Network Configuration for NAT. 2025-01-23 00:13:50 (26300): Enabling VM Network Access. 2025-01-23 00:13:50 (26300): Disabling USB Support for VM. 2025-01-23 00:13:51 (26300): Disabling COM Port Support for VM. 2025-01-23 00:13:51 (26300): Disabling LPT Port Support for VM. 2025-01-23 00:13:51 (26300): Disabling Audio Support for VM. 2025-01-23 00:13:52 (26300): Disabling Clipboard Support for VM. 2025-01-23 00:13:52 (26300): Disabling Drag and Drop Support for VM. 2025-01-23 00:13:52 (26300): Adding storage controller(s) to VM. 2025-01-23 00:13:52 (26300): Adding virtual disk drive to VM. (CMS_2025_01_16_prod.vdi) 2025-01-23 00:13:54 (26300): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2025-01-23 00:13:55 (26300): forwarding host port 55744 to guest port 80 2025-01-23 00:13:55 (26300): Enabling remote desktop for VM. 2025-01-23 00:13:55 (26300): Required extension pack not installed, remote desktop not enabled. 2025-01-23 00:13:55 (26300): Enabling shared directory for VM. 2025-01-23 00:13:56 (26300): Starting VM using VBoxManage interface. (boinc_a154f736f754b3d8, slot#7) 2025-01-23 00:13:56 (26300): Error in start VM for VM: 1 Command: VBoxManage -q startvm "boinc_a154f736f754b3d8" --type headless Output: VBoxManage.exe: error: The virtual machine 'boinc_a154f736f754b3d8' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\7\boinc_a154f736f754b3d8\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_a154f736f754b3d8" to power on... 2025-01-23 00:13:56 (26300): VM failed to start. 2025-01-23 00:13:56 (26300): Could not start 2025-01-23 00:13:56 (26300): ERROR: VM failed to start 2025-01-23 00:13:56 (26300): Powering off VM. 2025-01-23 00:13:56 (26300): Deregistering VM. (boinc_a154f736f754b3d8, slot#7) 2025-01-23 00:13:56 (26300): Removing network bandwidth throttle group from VM. 2025-01-23 00:13:56 (26300): Removing VM from VirtualBox. Hypervisor System Log: 00:00:05.506847 ERROR [COM]: aRC=VBOX_E_INVALID_OBJECT_STATE (0x80bb0007) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={Cannot attach medium 'C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\CMS_2025_01_16_prod.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later}, preserve=false aResultDetail=0 00:00:06.029808 Saving settings file "C:\Users\Brian\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:06.031375 Finished saving settings file "C:\Users\Brian\.VirtualBox\VirtualBox.xml" 00:00:06.557187 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:06.557449 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:06.557574 Saving settings file "C:\Users\Brian\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:06.559028 Finished saving settings file "C:\Users\Brian\.VirtualBox\VirtualBox.xml" 00:00:06.559261 Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_a154f736f754b3d8\boinc_a154f736f754b3d8.vbox" with version "1.19-windows" 00:00:06.560559 Finished saving settings file "C:\ProgramData\BOINC\slots\7\boinc_a154f736f754b3d8\boinc_a154f736f754b3d8.vbox" 00:00:06.821139 Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_a154f736f754b3d8\boinc_a154f736f754b3d8.vbox" with version "1.19-windows" 00:00:06.822420 Finished saving settings file "C:\ProgramData\BOINC\slots\7\boinc_a154f736f754b3d8\boinc_a154f736f754b3d8.vbox" 00:00:07.088555 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.088932 Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_a154f736f754b3d8\boinc_a154f736f754b3d8.vbox" with version "1.19-windows" 00:00:07.090252 Finished saving settings file "C:\ProgramData\BOINC\slots\7\boinc_a154f736f754b3d8\boinc_a154f736f754b3d8.vbox" 00:00:07.090336 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.091580 Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_a154f736f754b3d8\boinc_a154f736f754b3d8.vbox" with version "1.19-windows" 00:00:07.092914 Finished saving settings file "C:\ProgramData\BOINC\slots\7\boinc_a154f736f754b3d8\boinc_a154f736f754b3d8.vbox" 00:00:07.093164 Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_a154f736f754b3d8\boinc_a154f736f754b3d8.vbox" with version "1.19-windows" 00:00:07.094537 Finished saving settings file "C:\ProgramData\BOINC\slots\7\boinc_a154f736f754b3d8\boinc_a154f736f754b3d8.vbox" 00:00:07.355226 Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_a154f736f754b3d8\boinc_a154f736f754b3d8.vbox" with version "1.19-windows" 00:00:07.356740 Finished saving settings file "C:\ProgramData\BOINC\slots\7\boinc_a154f736f754b3d8\boinc_a154f736f754b3d8.vbox" 00:00:07.619275 Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_a154f736f754b3d8\boinc_a154f736f754b3d8.vbox" with version "1.19-windows" 00:00:07.620730 Finished saving settings file "C:\ProgramData\BOINC\slots\7\boinc_a154f736f754b3d8\boinc_a154f736f754b3d8.vbox" 00:00:08.148266 Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_a154f736f754b3d8\boinc_a154f736f754b3d8.vbox" with version "1.19-windows" 00:00:08.149597 Finished saving settings file "C:\ProgramData\BOINC\slots\7\boinc_a154f736f754b3d8\boinc_a154f736f754b3d8.vbox" 00:00:08.413393 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={Ńo extension pack providing a cryptographic support module could be found}, preserve=false aResultDetail=0 00:00:08.416796 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.416855 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.416936 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.417012 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.421696 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:08.677149 Launched VM: 2769053344 pid: 31788 (0x7c2c) frontend: headless name: boinc_a154f736f754b3d8 00:00:09.020114 Watcher ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The virtual machine 'boinc_a154f736f754b3d8' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\7\boinc_a154f736f754b3d8\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0 00:00:09.020363 Watcher Reaper: Pid 31788 (0x7c2c) exited normally: 1 (0x1) 00:00:09.052531 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:09.080467 Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_a154f736f754b3d8\boinc_a154f736f754b3d8.vbox" with version "1.19-windows" 00:00:09.081991 Finished saving settings file "C:\ProgramData\BOINC\slots\7\boinc_a154f736f754b3d8\boinc_a154f736f754b3d8.vbox" 00:00:09.347976 Saving settings file "C:\Users\Brian\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:09.349538 Finished saving settings file "C:\Users\Brian\.VirtualBox\VirtualBox.xml" 00:00:09.349595 Saving settings file "C:\Users\Brian\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:09.351074 Finished saving settings file "C:\Users\Brian\.VirtualBox\VirtualBox.xml" 00:00:09.351660 DeleteVM Saving settings file "C:\Users\Brian\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:09.353533 DeleteVM Finished saving settings file "C:\Users\Brian\.VirtualBox\VirtualBox.xml" 00:00:14.356219 main VirtualBox: object deletion starts 00:00:14.356827 main HostDnsMonitor: shutting down ... 00:00:14.356849 main HostDnsMonitor: shut down 00:00:14.357996 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:14.358132 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: 4f736f754b3d8' VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 3139 of file VBoxManageInfo.cpp 2025-01-23 00:13:48 (26300): Command: VBoxManage -q createvm --name "boinc_a154f736f754b3d8" --basefolder "C:\ProgramData\BOINC\slots\7" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_a154f736f754b3d8' is created and registered. UUID: 546d1165-5715-4cc9-9ba8-68ada150502c Settings file: 'C:\ProgramData\BOINC\slots\7\boinc_a154f736f754b3d8\boinc_a154f736f754b3d8.vbox' 2025-01-23 00:13:49 (26300): Command: VBoxManage -q modifyvm "boinc_a154f736f754b3d8" --description "CMS_1772211_1737607186.193568_0" Exit Code: 0 Output: 2025-01-23 00:13:49 (26300): Command: VBoxManage -q modifyvm "boinc_a154f736f754b3d8" --memory 4584 Exit Code: 0 Output: 2025-01-23 00:13:49 (26300): Command: VBoxManage -q modifyvm "boinc_a154f736f754b3d8" --cpus 4 Exit Code: 0 Output: 2025-01-23 00:13:49 (26300): Command: VBoxManage -q modifyvm "boinc_a154f736f754b3d8" --acpi on --ioapic on --rtcuseutc off Exit Code: 0 Output: 2025-01-23 00:13:50 (26300): Command: VBoxManage -q modifyvm "boinc_a154f736f754b3d8" --vram 16 --graphicscontroller VBoxVGA Exit Code: 0 Output: 2025-01-23 00:13:50 (26300): Command: VBoxManage -q modifyvm "boinc_a154f736f754b3d8" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2025-01-23 00:13:50 (26300): Command: VBoxManage -q modifyvm "boinc_a154f736f754b3d8" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2025-01-23 00:13:50 (26300): Command: VBoxManage -q modifyvm "boinc_a154f736f754b3d8" --cableconnected1 on Exit Code: 0 Output: 2025-01-23 00:13:51 (26300): Command: VBoxManage -q modifyvm "boinc_a154f736f754b3d8" --usb off Exit Code: 0 Output: 2025-01-23 00:13:51 (26300): Command: VBoxManage -q modifyvm "boinc_a154f736f754b3d8" --uart1 off --uart2 off Exit Code: 0 Output: 2025-01-23 00:13:51 (26300): Command: VBoxManage -q modifyvm "boinc_a154f736f754b3d8" --lpt1 off --lpt2 off Exit Code: 0 Output: 2025-01-23 00:13:52 (26300): Command: VBoxManage -q modifyvm "boinc_a154f736f754b3d8" --audio-enabled off Exit Code: 0 Output: 2025-01-23 00:13:52 (26300): Command: VBoxManage -q modifyvm "boinc_a154f736f754b3d8" --clipboard disabled Exit Code: 0 Output: 2025-01-23 00:13:52 (26300): Command: VBoxManage -q modifyvm "boinc_a154f736f754b3d8" --draganddrop disabled Exit Code: 0 Output: 2025-01-23 00:13:52 (26300): Command: VBoxManage -q storagectl "boinc_a154f736f754b3d8" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2025-01-23 00:13:53 (26300): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2025_01_16_prod.vdi" Exit Code: 0 Output: UUID: 3da9ab36-1206-4cc3-8a9a-8d4138ab45c5 Parent UUID: base State: created Type: multiattach Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\CMS_2025_01_16_prod.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 3853 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-01-23 00:13:53 (26300): Command: VBoxManage -q storageattach "boinc_a154f736f754b3d8" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2025_01_16_prod.vdi" Exit Code: -2135228409 Output: VBoxManage.exe: error: Cannot attach medium 'C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\CMS_2025_01_16_prod.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 785 of file VBoxManageStorageController.cpp 2025-01-23 00:13:53 (26300): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2025_01_16_prod.vdi" Exit Code: 0 Output: UUID: 3da9ab36-1206-4cc3-8a9a-8d4138ab45c5 Parent UUID: base State: created Type: multiattach Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\CMS_2025_01_16_prod.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 3853 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-01-23 00:13:53 (26300): Command: VBoxManage -q closemedium disk "C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\CMS_2025_01_16_prod.vdi" Exit Code: 0 Output: 2025-01-23 00:13:54 (26300): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2025_01_16_prod.vdi" Exit Code: 0 Output: UUID: 3da9ab36-1206-4cc3-8a9a-8d4138ab45c5 Parent UUID: base State: created Type: normal (base) Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\CMS_2025_01_16_prod.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 3853 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-01-23 00:13:54 (26300): Command: VBoxManage -q storageattach "boinc_a154f736f754b3d8" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2025_01_16_prod.vdi" Exit Code: 0 Output: 2025-01-23 00:13:54 (26300): Command: VBoxManage -q storageattach "boinc_a154f736f754b3d8" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none Exit Code: 0 Output: 2025-01-23 00:13:54 (26300): Command: VBoxManage -q storageattach "boinc_a154f736f754b3d8" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2025_01_16_prod.vdi" Exit Code: 0 Output: 2025-01-23 00:13:55 (26300): Command: VBoxManage -q bandwidthctl "boinc_a154f736f754b3d8" add "boinc_a154f736f754b3d8_net" --type network --limit 1024G Exit Code: 0 Output: 2025-01-23 00:13:55 (26300): Command: VBoxManage -q modifyvm "boinc_a154f736f754b3d8" --natpf1 ",tcp,127.0.0.1,55744,,80" Exit Code: 0 Output: 2025-01-23 00:13:55 (26300): Command: VBoxManage -q list extpacks Exit Code: 0 Output: Extension Packs: 0 2025-01-23 00:13:55 (26300): Command: VBoxManage -q sharedfolder add "boinc_a154f736f754b3d8" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\7/shared" Exit Code: 0 Output: 2025-01-23 00:13:56 (26300): Command: VBoxManage -q startvm "boinc_a154f736f754b3d8" --type headless Exit Code: 1 Output: VBoxManage.exe: error: The virtual machine 'boinc_a154f736f754b3d8' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\7\boinc_a154f736f754b3d8\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_a154f736f754b3d8" to power on... 2025-01-23 00:13:56 (26300): Command: VBoxManage -q snapshot "boinc_a154f736f754b3d8" list Exit Code: -108 Output: This machine does not have any snapshots 2025-01-23 00:13:56 (26300): Command: VBoxManage -q bandwidthctl "boinc_a154f736f754b3d8" remove "boinc_a154f736f754b3d8_net" Exit Code: 0 Output: 2025-01-23 00:13:57 (26300): Command: VBoxManage -q unregistervm "boinc_a154f736f754b3d8" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 2025-01-23 00:14:02 (26300): called boinc_finish(1) </stderr_txt> ]]>
©2025 CERN