Name | Theory_2773-2915167-405_1 |
Workunit | 229896662 |
Created | 22 Jan 2025, 20:07:41 UTC |
Sent | 23 Jan 2025, 1:48:23 UTC |
Report deadline | 3 Feb 2025, 1:48:23 UTC |
Received | 23 Jan 2025, 4:50:18 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | -2147467259 (0x80004005) Unknown error code |
Computer ID | 10670761 |
Run time | 24 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 4.92 GFLOPS |
Application version | Theory Simulation v300.60 (vbox64_theory) windows_x86_64 |
Peak working set size | 10.83 MB |
Peak swap size | 5.25 MB |
Peak disk usage | 0.87 MB |
<core_client_version>8.0.2</core_client_version> <![CDATA[ <message> Unspecified error (0x80004005) - exit code 2147500037 (0x80004005)</message> <stderr_txt> 2025-01-22 19:48:57 (1776): vboxwrapper version 26208 2025-01-22 19:48:57 (1776): BOINC client version: 8.0.2 2025-01-22 19:48:59 (1776): Detected: VirtualBox VboxManage Interface (Version: 7.0.20) 2025-01-22 19:48:59 (1776): Detected: Heartbeat check (file: 'heartbeat' every 1200.000000 seconds) 2025-01-22 19:48:59 (1776): Successfully copied 'init_data.xml' to the shared directory. 2025-01-22 19:48:59 (1776): Successfully copied 'input' to the shared directory. 2025-01-22 19:48:59 (1776): Create VM. (boinc_7273fb77e7c202c4, slot#16) 2025-01-22 19:49:00 (1776): Setting Memory Size for VM. (630MB) 2025-01-22 19:49:00 (1776): Setting CPU Count for VM. (1) 2025-01-22 19:49:01 (1776): Setting Chipset Options for VM. 2025-01-22 19:49:01 (1776): Setting Graphics Controller Options for VM. 2025-01-22 19:49:01 (1776): Setting Boot Options for VM. 2025-01-22 19:49:02 (1776): Setting Network Configuration for NAT. 2025-01-22 19:49:02 (1776): Enabling VM Network Access. 2025-01-22 19:49:02 (1776): Disabling USB Support for VM. 2025-01-22 19:49:03 (1776): Disabling COM Port Support for VM. 2025-01-22 19:49:03 (1776): Disabling LPT Port Support for VM. 2025-01-22 19:49:03 (1776): Disabling Audio Support for VM. 2025-01-22 19:49:04 (1776): Disabling Clipboard Support for VM. 2025-01-22 19:49:04 (1776): Disabling Drag and Drop Support for VM. 2025-01-22 19:49:04 (1776): Adding storage controller(s) to VM. 2025-01-22 19:49:05 (1776): Adding virtual disk drive to VM. (Theory_2025_01_16_prod.vdi) 2025-01-22 19:49:08 (1776): Adding VirtualBox Guest Additions to VM. 2025-01-22 19:49:08 (1776): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2025-01-22 19:49:08 (1776): forwarding host port 52264 to guest port 80 2025-01-22 19:49:09 (1776): Enabling remote desktop for VM. 2025-01-22 19:49:09 (1776): Enabling shared directory for VM. 2025-01-22 19:49:10 (1776): Starting VM using VBoxManage interface. (boinc_7273fb77e7c202c4, slot#16) 2025-01-22 19:49:14 (1776): Error in start VM for VM: -2147467259 Command: VBoxManage -q startvm "boinc_7273fb77e7c202c4" --type headless Output: VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: AMD-V is disabled in the BIOS (or by the host OS) (VERR_SVM_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole Waiting for VM "boinc_7273fb77e7c202c4" to power on... 2025-01-22 19:49:14 (1776): VM failed to start. 2025-01-22 19:49:14 (1776): Could not start 2025-01-22 19:49:14 (1776): ERROR: VM failed to start 2025-01-22 19:49:14 (1776): Powering off VM. 2025-01-22 19:49:14 (1776): Deregistering VM. (boinc_7273fb77e7c202c4, slot#16) 2025-01-22 19:49:14 (1776): Removing network bandwidth throttle group from VM. 2025-01-22 19:49:14 (1776): Removing VM from VirtualBox. Hypervisor System Log: 00:00:09.948126 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.948273 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:09.948396 Saving settings file "C:\Users\Evolve X\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:09.957213 Finished saving settings file "C:\Users\Evolve X\.VirtualBox\VirtualBox.xml" 00:00:09.957569 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:09.957636 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:09.957756 Saving settings file "C:\Users\Evolve X\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:09.967873 Finished saving settings file "C:\Users\Evolve X\.VirtualBox\VirtualBox.xml" 00:00:09.968477 Saving settings file "C:\ProgramData\BOINC\slots\16\boinc_7273fb77e7c202c4\boinc_7273fb77e7c202c4.vbox" with version "1.19-windows" 00:00:09.977439 Finished saving settings file "C:\ProgramData\BOINC\slots\16\boinc_7273fb77e7c202c4\boinc_7273fb77e7c202c4.vbox" 00:00:10.300149 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:10.303304 Saving settings file "C:\ProgramData\BOINC\slots\16\boinc_7273fb77e7c202c4\boinc_7273fb77e7c202c4.vbox" with version "1.19-windows" 00:00:10.312534 Finished saving settings file "C:\ProgramData\BOINC\slots\16\boinc_7273fb77e7c202c4\boinc_7273fb77e7c202c4.vbox" 00:00:10.641985 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:10.645735 Saving settings file "C:\ProgramData\BOINC\slots\16\boinc_7273fb77e7c202c4\boinc_7273fb77e7c202c4.vbox" with version "1.19-windows" 00:00:10.654935 Finished saving settings file "C:\ProgramData\BOINC\slots\16\boinc_7273fb77e7c202c4\boinc_7273fb77e7c202c4.vbox" 00:00:11.291231 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:11.295296 Saving settings file "C:\ProgramData\BOINC\slots\16\boinc_7273fb77e7c202c4\boinc_7273fb77e7c202c4.vbox" with version "1.19-windows" 00:00:11.303885 Finished saving settings file "C:\ProgramData\BOINC\slots\16\boinc_7273fb77e7c202c4\boinc_7273fb77e7c202c4.vbox" 00:00:11.580284 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:11.582941 Saving settings file "C:\ProgramData\BOINC\slots\16\boinc_7273fb77e7c202c4\boinc_7273fb77e7c202c4.vbox" with version "1.19-windows" 00:00:11.594913 Finished saving settings file "C:\ProgramData\BOINC\slots\16\boinc_7273fb77e7c202c4\boinc_7273fb77e7c202c4.vbox" 00:00:11.845682 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:11.847817 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={Ńo extension pack providing a cryptographic support module could be found}, preserve=false aResultDetail=0 00:00:11.856268 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:11.856381 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:11.866276 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:12.106270 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:12.117111 Launched VM: 1314575136 pid: 7024 (0x1b70) frontend: headless name: boinc_7273fb77e7c202c4 00:00:16.020472 Saving settings file "C:\ProgramData\BOINC\slots\16\boinc_7273fb77e7c202c4\boinc_7273fb77e7c202c4.vbox" with version "1.19-windows" 00:00:16.029364 Finished saving settings file "C:\ProgramData\BOINC\slots\16\boinc_7273fb77e7c202c4\boinc_7273fb77e7c202c4.vbox" 00:00:16.226903 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:16.228803 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:16.399022 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:16.401442 Saving settings file "C:\ProgramData\BOINC\slots\16\boinc_7273fb77e7c202c4\boinc_7273fb77e7c202c4.vbox" with version "1.19-windows" 00:00:16.410147 Finished saving settings file "C:\ProgramData\BOINC\slots\16\boinc_7273fb77e7c202c4\boinc_7273fb77e7c202c4.vbox" 00:00:16.731004 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:16.731396 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:16.731500 Saving settings file "C:\Users\Evolve X\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:16.740192 Finished saving settings file "C:\Users\Evolve X\.VirtualBox\VirtualBox.xml" 00:00:16.740327 Saving settings file "C:\Users\Evolve X\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:16.747573 Finished saving settings file "C:\Users\Evolve X\.VirtualBox\VirtualBox.xml" 00:00:16.748693 DeleteVM Saving settings file "C:\Users\Evolve X\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:16.756436 DeleteVM Finished saving settings file "C:\Users\Evolve X\.VirtualBox\VirtualBox.xml" 00:00:21.751781 main VirtualBox: object deletion starts 00:00:21.753110 main HostDnsMonitor: shutting down ... 00:00:21.753157 main HostDnsMonitor: shut down 00:00:21.755234 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:21.755570 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: 7c202c4" --memory 630 Exit Code: 0 Output: 2025-01-22 19:49:01 (1776): Command: VBoxManage -q modifyvm "boinc_7273fb77e7c202c4" --cpus 1 Exit Code: 0 Output: 2025-01-22 19:49:01 (1776): Command: VBoxManage -q modifyvm "boinc_7273fb77e7c202c4" --acpi on --ioapic on --rtcuseutc off Exit Code: 0 Output: 2025-01-22 19:49:01 (1776): Command: VBoxManage -q modifyvm "boinc_7273fb77e7c202c4" --vram 16 --graphicscontroller VBoxVGA Exit Code: 0 Output: 2025-01-22 19:49:01 (1776): Command: VBoxManage -q modifyvm "boinc_7273fb77e7c202c4" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2025-01-22 19:49:02 (1776): Command: VBoxManage -q modifyvm "boinc_7273fb77e7c202c4" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2025-01-22 19:49:02 (1776): Command: VBoxManage -q modifyvm "boinc_7273fb77e7c202c4" --cableconnected1 on Exit Code: 0 Output: 2025-01-22 19:49:03 (1776): Command: VBoxManage -q modifyvm "boinc_7273fb77e7c202c4" --usb off Exit Code: 0 Output: 2025-01-22 19:49:03 (1776): Command: VBoxManage -q modifyvm "boinc_7273fb77e7c202c4" --uart1 off --uart2 off Exit Code: 0 Output: 2025-01-22 19:49:03 (1776): Command: VBoxManage -q modifyvm "boinc_7273fb77e7c202c4" --lpt1 off --lpt2 off Exit Code: 0 Output: 2025-01-22 19:49:04 (1776): Command: VBoxManage -q modifyvm "boinc_7273fb77e7c202c4" --audio-enabled off Exit Code: 0 Output: 2025-01-22 19:49:04 (1776): Command: VBoxManage -q modifyvm "boinc_7273fb77e7c202c4" --clipboard disabled Exit Code: 0 Output: 2025-01-22 19:49:04 (1776): Command: VBoxManage -q modifyvm "boinc_7273fb77e7c202c4" --draganddrop disabled Exit Code: 0 Output: 2025-01-22 19:49:05 (1776): Command: VBoxManage -q storagectl "boinc_7273fb77e7c202c4" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2025-01-22 19:49:05 (1776): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2025_01_16_prod.vdi" Exit Code: 0 Output: UUID: 6a4110e9-e559-4c1c-bfd2-ba6f6aaf4169 Parent UUID: base State: created Type: multiattach Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\Theory_2025_01_16_prod.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 781 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-01-22 19:49:05 (1776): Command: VBoxManage -q storageattach "boinc_7273fb77e7c202c4" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2025_01_16_prod.vdi" Exit Code: -2135228409 Output: VBoxManage.exe: error: Cannot attach medium 'C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\Theory_2025_01_16_prod.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 785 of file VBoxManageStorageController.cpp 2025-01-22 19:49:06 (1776): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2025_01_16_prod.vdi" Exit Code: 0 Output: UUID: 6a4110e9-e559-4c1c-bfd2-ba6f6aaf4169 Parent UUID: base State: created Type: multiattach Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\Theory_2025_01_16_prod.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 781 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-01-22 19:49:06 (1776): Command: VBoxManage -q closemedium disk "C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\Theory_2025_01_16_prod.vdi" Exit Code: 0 Output: 2025-01-22 19:49:07 (1776): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2025_01_16_prod.vdi" Exit Code: 0 Output: UUID: 6a4110e9-e559-4c1c-bfd2-ba6f6aaf4169 Parent UUID: base State: created Type: normal (base) Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\Theory_2025_01_16_prod.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 781 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-01-22 19:49:07 (1776): Command: VBoxManage -q storageattach "boinc_7273fb77e7c202c4" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2025_01_16_prod.vdi" Exit Code: 0 Output: 2025-01-22 19:49:07 (1776): Command: VBoxManage -q storageattach "boinc_7273fb77e7c202c4" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none Exit Code: 0 Output: 2025-01-22 19:49:08 (1776): Command: VBoxManage -q storageattach "boinc_7273fb77e7c202c4" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2025_01_16_prod.vdi" Exit Code: 0 Output: 2025-01-22 19:49:08 (1776): Command: VBoxManage -q storageattach "boinc_7273fb77e7c202c4" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2025-01-22 19:49:08 (1776): Command: VBoxManage -q bandwidthctl "boinc_7273fb77e7c202c4" add "boinc_7273fb77e7c202c4_net" --type network --limit 1024G Exit Code: 0 Output: 2025-01-22 19:49:09 (1776): Command: VBoxManage -q modifyvm "boinc_7273fb77e7c202c4" --natpf1 ",tcp,127.0.0.1,52264,,80" Exit Code: 0 Output: 2025-01-22 19:49:09 (1776): Command: VBoxManage -q list extpacks Exit Code: 0 Output: Extension Packs: 1 Pack no. 0: Oracle VM VirtualBox Extension Pack Version: 6.1.16 Revision: 140961 Edition: Description: Oracle Cloud Infrastructure integration, USB 2.0 and USB 3.0 Host Controller, Host Webcam, VirtualBox RDP, PXE ROM, Disk Encryption, NVMe. VRDE Module: VBoxVRDP Crypto Module: Usable: false Why unusable: VBoxExtPackRegister returned VERR_VERSION_MISMATCH, pReg=0000000000000000 ErrInfo='Helper version mismatch - expected 0x3 got 0x50000' 2025-01-22 19:49:09 (1776): Command: VBoxManage -q modifyvm "boinc_7273fb77e7c202c4" --vrde on --vrdeextpack default --vrdeauthlibrary default --vrdeauthtype null --vrdeport 52265 --vrde-property "Security/Method=RDP" Exit Code: 0 Output: 2025-01-22 19:49:10 (1776): Command: VBoxManage -q sharedfolder add "boinc_7273fb77e7c202c4" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\16/shared" Exit Code: 0 Output: 2025-01-22 19:49:14 (1776): Command: VBoxManage -q startvm "boinc_7273fb77e7c202c4" --type headless Exit Code: -2147467259 Output: VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: AMD-V is disabled in the BIOS (or by the host OS) (VERR_SVM_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole Waiting for VM "boinc_7273fb77e7c202c4" to power on... 2025-01-22 19:49:14 (1776): Command: VBoxManage -q snapshot "boinc_7273fb77e7c202c4" list Exit Code: -108 Output: This machine does not have any snapshots 2025-01-22 19:49:14 (1776): Command: VBoxManage -q bandwidthctl "boinc_7273fb77e7c202c4" remove "boinc_7273fb77e7c202c4_net" Exit Code: 0 Output: 2025-01-22 19:49:15 (1776): Command: VBoxManage -q unregistervm "boinc_7273fb77e7c202c4" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 2025-01-22 19:49:20 (1776): called boinc_finish(-2147467259) </stderr_txt> ]]>
©2025 CERN