Name Theory_2773-3010035-384_2
Workunit 229883166
Created 22 Jan 2025, 13:31:29 UTC
Sent 22 Jan 2025, 21:02:15 UTC
Report deadline 2 Feb 2025, 21:02:15 UTC
Received 22 Jan 2025, 21:31:27 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status -2147467259 (0x80004005) Unknown error code
Computer ID 10670761
Run time 23 sec
CPU time
Validate state Invalid
Credit 0.00
Device peak FLOPS 4.92 GFLOPS
Application version Theory Simulation v300.60 (vbox64_theory)
windows_x86_64
Peak working set size 10.85 MB
Peak swap size 5.25 MB
Peak disk usage 1.01 MB

Stderr output

<core_client_version>8.0.2</core_client_version>
<![CDATA[
<message>
Unspecified error
 (0x80004005) - exit code 2147500037 (0x80004005)</message>
<stderr_txt>
2025-01-22 15:02:21 (27908): vboxwrapper version 26208
2025-01-22 15:02:21 (27908): BOINC client version: 8.0.2
2025-01-22 15:02:22 (27908): Detected: VirtualBox VboxManage Interface (Version: 7.0.20)
2025-01-22 15:02:22 (27908): Detected: Heartbeat check (file: 'heartbeat' every 1200.000000 seconds)
2025-01-22 15:02:22 (27908): Successfully copied 'init_data.xml' to the shared directory.
2025-01-22 15:02:22 (27908): Successfully copied 'input' to the shared directory.
2025-01-22 15:02:22 (27908): Create VM. (boinc_94ef0a7c3ee918b0, slot#19)
2025-01-22 15:02:23 (27908): Setting Memory Size for VM. (630MB)
2025-01-22 15:02:23 (27908): Setting CPU Count for VM. (1)
2025-01-22 15:02:24 (27908): Setting Chipset Options for VM.
2025-01-22 15:02:24 (27908): Setting Graphics Controller Options for VM.
2025-01-22 15:02:24 (27908): Setting Boot Options for VM.
2025-01-22 15:02:24 (27908): Setting Network Configuration for NAT.
2025-01-22 15:02:25 (27908): Enabling VM Network Access.
2025-01-22 15:02:25 (27908): Disabling USB Support for VM.
2025-01-22 15:02:25 (27908): Disabling COM Port Support for VM.
2025-01-22 15:02:25 (27908): Disabling LPT Port Support for VM.
2025-01-22 15:02:26 (27908): Disabling Audio Support for VM.
2025-01-22 15:02:26 (27908): Disabling Clipboard Support for VM.
2025-01-22 15:02:26 (27908): Disabling Drag and Drop Support for VM.
2025-01-22 15:02:27 (27908): Adding storage controller(s) to VM.
2025-01-22 15:02:27 (27908): Adding virtual disk drive to VM. (Theory_2025_01_16_prod.vdi)
2025-01-22 15:02:31 (27908): Attempts: 3
2025-01-22 15:02:32 (27908): Adding VirtualBox Guest Additions to VM.
2025-01-22 15:02:32 (27908): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2025-01-22 15:02:32 (27908): forwarding host port 49723 to guest port 80
2025-01-22 15:02:33 (27908): Enabling remote desktop for VM.
2025-01-22 15:02:33 (27908): Enabling shared directory for VM.
2025-01-22 15:02:34 (27908): Starting VM using VBoxManage interface. (boinc_94ef0a7c3ee918b0, slot#19)
2025-01-22 15:02:37 (27908): Error in start VM for VM: -2147467259
Command:
VBoxManage -q startvm "boinc_94ef0a7c3ee918b0" --type headless
Output:
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: AMD-V is disabled in the BIOS (or by the host OS) (VERR_SVM_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole
Waiting for VM "boinc_94ef0a7c3ee918b0" to power on...

2025-01-22 15:02:37 (27908): VM failed to start.
2025-01-22 15:02:37 (27908): Could not start 
2025-01-22 15:02:37 (27908): ERROR: VM failed to start
2025-01-22 15:02:37 (27908): Powering off VM.
2025-01-22 15:02:37 (27908): Deregistering VM. (boinc_94ef0a7c3ee918b0, slot#19)
2025-01-22 15:02:37 (27908): Removing network bandwidth throttle group from VM.
2025-01-22 15:02:38 (27908): Removing VM from VirtualBox.

    Hypervisor System Log:

00:00:15.441689 DeleteVM Finished saving settings file "C:\Users\Evolve X\.VirtualBox\VirtualBox.xml"
00:00:16.143153          Saving settings file "C:\ProgramData\BOINC\slots\18\boinc_bfcdeec1c00d4e22\boinc_bfcdeec1c00d4e22.vbox" with version "1.19-windows"
00:00:16.149586          Finished saving settings file "C:\ProgramData\BOINC\slots\18\boinc_bfcdeec1c00d4e22\boinc_bfcdeec1c00d4e22.vbox"
00:00:16.224992          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:16.226755          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:16.285847          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:16.548263          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:16.548614          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:16.548730          Saving settings file "C:\Users\Evolve X\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:16.554556          Finished saving settings file "C:\Users\Evolve X\.VirtualBox\VirtualBox.xml"
00:00:16.554628          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:16.554822          Saving settings file "C:\ProgramData\BOINC\slots\20\boinc_ea702d0988645586\boinc_ea702d0988645586.vbox" with version "1.19-windows"
00:00:16.560184          Finished saving settings file "C:\ProgramData\BOINC\slots\20\boinc_ea702d0988645586\boinc_ea702d0988645586.vbox"
00:00:16.561088 DeleteVM ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:16.561367 DeleteVM Saving settings file "C:\ProgramData\BOINC\slots\20\boinc_ea702d0988645586\boinc_ea702d0988645586.vbox" with version "1.19-windows"
00:00:16.567126 DeleteVM Finished saving settings file "C:\ProgramData\BOINC\slots\20\boinc_ea702d0988645586\boinc_ea702d0988645586.vbox"
00:00:16.828585          Saving settings file "C:\ProgramData\BOINC\slots\20\boinc_ea702d0988645586\boinc_ea702d0988645586.vbox" with version "1.19-windows"
00:00:16.834508          Finished saving settings file "C:\ProgramData\BOINC\slots\20\boinc_ea702d0988645586\boinc_ea702d0988645586.vbox"
00:00:16.910153          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:16.911839          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:16.967684          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:16.969942          Saving settings file "C:\ProgramData\BOINC\slots\20\boinc_ea702d0988645586\boinc_ea702d0988645586.vbox" with version "1.19-windows"
00:00:16.975713          Finished saving settings file "C:\ProgramData\BOINC\slots\20\boinc_ea702d0988645586\boinc_ea702d0988645586.vbox"
00:00:17.245655          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:17.245999          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:17.246091          Saving settings file "C:\Users\Evolve X\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:17.251738          Finished saving settings file "C:\Users\Evolve X\.VirtualBox\VirtualBox.xml"
00:00:17.251818          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:17.252020          Saving settings file "C:\ProgramData\BOINC\slots\19\boinc_94ef0a7c3ee918b0\boinc_94ef0a7c3ee918b0.vbox" with version "1.19-windows"
00:00:17.257640          Finished saving settings file "C:\ProgramData\BOINC\slots\19\boinc_94ef0a7c3ee918b0\boinc_94ef0a7c3ee918b0.vbox"
00:00:17.258601 DeleteVM ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:17.258936 DeleteVM Saving settings file "C:\ProgramData\BOINC\slots\19\boinc_94ef0a7c3ee918b0\boinc_94ef0a7c3ee918b0.vbox" with version "1.19-windows"
00:00:17.264626 DeleteVM Finished saving settings file "C:\ProgramData\BOINC\slots\19\boinc_94ef0a7c3ee918b0\boinc_94ef0a7c3ee918b0.vbox"
00:00:18.740160          Saving settings file "C:\ProgramData\BOINC\slots\19\boinc_94ef0a7c3ee918b0\boinc_94ef0a7c3ee918b0.vbox" with version "1.19-windows"
00:00:18.746054          Finished saving settings file "C:\ProgramData\BOINC\slots\19\boinc_94ef0a7c3ee918b0\boinc_94ef0a7c3ee918b0.vbox"
00:00:18.818228          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:18.820122          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:18.874701          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:19.142247          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:19.142595          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:00:19.142707          Saving settings file "C:\Users\Evolve X\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:19.149128          Finished saving settings file "C:\Users\Evolve X\.VirtualBox\VirtualBox.xml"
00:00:19.149263          Saving settings file "C:\Users\Evolve X\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:19.154552          Finished saving settings file "C:\Users\Evolve X\.VirtualBox\VirtualBox.xml"
00:00:19.155543 DeleteVM Saving settings file "C:\Users\Evolve X\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:19.161015 DeleteVM Finished saving settings file "C:\Users\Evolve X\.VirtualBox\VirtualBox.xml"
00:00:24.175737 main     VirtualBox: object deletion starts
00:00:24.177218 main     HostDnsMonitor: shutting down ...
00:00:24.177274 main     HostDnsMonitor: shut down
00:00:24.179125 Watcher  ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0
00:00:24.179367 main     VirtualBox: object deleted

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

Ryzen 7 2700X Eight-Core Processor
Processor#4 speed: unknown
Processor#4 description: AMD Ryzen 7 2700X Eight-Core Processor
Processor#5 speed: unknown
Processor#5 description: AMD Ryzen 7 2700X Eight-Core Processor
Processor#6 speed: unknown
Processor#6 description: AMD Ryzen 7 2700X Eight-Core Processor
Processor#7 speed: unknown
Processor#7 description: AMD Ryzen 7 2700X Eight-Core Processor
Processor#8 speed: unknown
Processor#8 description: AMD Ryzen 7 2700X Eight-Core Processor
Processor#9 speed: unknown
Processor#9 description: AMD Ryzen 7 2700X Eight-Core Processor
Processor#10 speed: unknown
Processor#10 description: AMD Ryzen 7 2700X Eight-Core Processor
Processor#11 speed: unknown
Processor#11 description: AMD Ryzen 7 2700X Eight-Core Processor
Processor#12 speed: unknown
Processor#12 description: AMD Ryzen 7 2700X Eight-Core Processor
Processor#13 speed: unknown
Processor#13 description: AMD Ryzen 7 2700X Eight-Core Processor
Processor#14 speed: unknown
Processor#14 description: AMD Ryzen 7 2700X Eight-Core Processor
Processor#15 speed: unknown
Processor#15 description: AMD Ryzen 7 2700X Eight-Core Processor
Memory size: 16304 MByte
Memory available: 10412 MByte
Operating system: Windows 11
Operating system version: 10.0.22631

2025-01-22 15:02:22 (27908): 
Command: VBoxManage -q showvminfo "boinc_94ef0a7c3ee918b0" --machinereadable 
Exit Code: -2135228415
Output:
VBoxManage.exe: error: Could not find a registered machine named 'boinc_94ef0a7c3ee918b0'
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown
VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 3139 of file VBoxManageInfo.cpp

2025-01-22 15:02:23 (27908): 
Command: VBoxManage -q createvm --name "boinc_94ef0a7c3ee918b0" --basefolder "C:\ProgramData\BOINC\slots\19" --ostype "Linux26_64" --register
Exit Code: 0
Output:
Virtual machine 'boinc_94ef0a7c3ee918b0' is created and registered.
UUID: 94c0a975-7bf1-4333-bb3e-47487f49fefc
Settings file: 'C:\ProgramData\BOINC\slots\19\boinc_94ef0a7c3ee918b0\boinc_94ef0a7c3ee918b0.vbox'

2025-01-22 15:02:23 (27908): 
Command: VBoxManage -q modifyvm "boinc_94ef0a7c3ee918b0" --description "Theory_2773-3010035-384_2" 
Exit Code: 0
Output:

2025-01-22 15:02:23 (27908): 
Command: VBoxManage -q modifyvm "boinc_94ef0a7c3ee918b0" --memory 630 
Exit Code: 0
Output:

2025-01-22 15:02:24 (27908): 
Command: VBoxManage -q modifyvm "boinc_94ef0a7c3ee918b0" --cpus 1 
Exit Code: 0
Output:

2025-01-22 15:02:24 (27908): 
Command: VBoxManage -q modifyvm "boinc_94ef0a7c3ee918b0" --acpi on --ioapic on --rtcuseutc off 
Exit Code: 0
Output:

2025-01-22 15:02:24 (27908): 
Command: VBoxManage -q modifyvm "boinc_94ef0a7c3ee918b0" --vram 16 --graphicscontroller VBoxVGA 
Exit Code: 0
Output:

2025-01-22 15:02:24 (27908): 
Command: VBoxManage -q modifyvm "boinc_94ef0a7c3ee918b0" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2025-01-22 15:02:25 (27908): 
Command: VBoxManage -q modifyvm "boinc_94ef0a7c3ee918b0" --nic1 nat --natdnsproxy1 on --cableconnected1 off 
Exit Code: 0
Output:

2025-01-22 15:02:25 (27908): 
Command: VBoxManage -q modifyvm "boinc_94ef0a7c3ee918b0" --cableconnected1 on 
Exit Code: 0
Output:

2025-01-22 15:02:25 (27908): 
Command: VBoxManage -q modifyvm "boinc_94ef0a7c3ee918b0" --usb off 
Exit Code: 0
Output:

2025-01-22 15:02:25 (27908): 
Command: VBoxManage -q modifyvm "boinc_94ef0a7c3ee918b0" --uart1 off --uart2 off 
Exit Code: 0
Output:

2025-01-22 15:02:26 (27908): 
Command: VBoxManage -q modifyvm "boinc_94ef0a7c3ee918b0" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2025-01-22 15:02:26 (27908): 
Command: VBoxManage -q modifyvm "boinc_94ef0a7c3ee918b0" --audio-enabled off 
Exit Code: 0
Output:

2025-01-22 15:02:26 (27908): 
Command: VBoxManage -q modifyvm "boinc_94ef0a7c3ee918b0" --clipboard disabled 
Exit Code: 0
Output:

2025-01-22 15:02:27 (27908): 
Command: VBoxManage -q modifyvm "boinc_94ef0a7c3ee918b0" --draganddrop disabled 
Exit Code: 0
Output:

2025-01-22 15:02:27 (27908): 
Command: VBoxManage -q storagectl "boinc_94ef0a7c3ee918b0" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2025-01-22 15:02:32 (27908): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2025_01_16_prod.vdi" 
Exit Code: 0
Output:
UUID:           6a4110e9-e559-4c1c-bfd2-ba6f6aaf4169
Parent UUID:    base
State:          created
Type:           multiattach
Location:       C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\Theory_2025_01_16_prod.vdi
Storage format: VDI
Format variant: dynamic default
Capacity:       20480 MBytes
Size on disk:   781 MBytes
Encryption:     disabled
Property:       AllocationBlockSize=1048576
Child UUIDs:    7739e3d7-a63f-4fa7-bd8c-832957a01b3e
                feab08d8-8497-4a02-9af4-87100fea5e61
                1c42eb3c-021f-4105-a57e-533d7301a7a7

2025-01-22 15:02:32 (27908): 
Command: VBoxManage -q storageattach "boinc_94ef0a7c3ee918b0" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2025_01_16_prod.vdi" 
Exit Code: 0
Output:

2025-01-22 15:02:32 (27908): 
Command: VBoxManage -q storageattach "boinc_94ef0a7c3ee918b0" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2025-01-22 15:02:32 (27908): 
Command: VBoxManage -q bandwidthctl "boinc_94ef0a7c3ee918b0" add "boinc_94ef0a7c3ee918b0_net" --type network --limit 1024G 
Exit Code: 0
Output:

2025-01-22 15:02:33 (27908): 
Command: VBoxManage -q modifyvm "boinc_94ef0a7c3ee918b0" --natpf1 ",tcp,127.0.0.1,49723,,80" 
Exit Code: 0
Output:

2025-01-22 15:02:33 (27908): 
Command: VBoxManage -q list extpacks
Exit Code: 0
Output:
Extension Packs: 1
Pack no. 0:   Oracle VM VirtualBox Extension Pack
Version:        6.1.16
Revision:       140961
Edition:        
Description:    Oracle Cloud Infrastructure integration, USB 2.0 and USB 3.0 Host Controller, Host Webcam, VirtualBox RDP, PXE ROM, Disk Encryption, NVMe.
VRDE Module:    VBoxVRDP
Crypto Module:  
Usable:         false
Why unusable:   VBoxExtPackRegister returned VERR_VERSION_MISMATCH, pReg=0000000000000000 ErrInfo='Helper version mismatch - expected 0x3 got 0x50000'

2025-01-22 15:02:33 (27908): 
Command: VBoxManage -q modifyvm "boinc_94ef0a7c3ee918b0" --vrde on --vrdeextpack default --vrdeauthlibrary default --vrdeauthtype null --vrdeport 49724 --vrde-property "Security/Method=RDP" 
Exit Code: 0
Output:

2025-01-22 15:02:33 (27908): 
Command: VBoxManage -q sharedfolder add "boinc_94ef0a7c3ee918b0" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\19/shared"
Exit Code: 0
Output:

2025-01-22 15:02:37 (27908): 
Command: VBoxManage -q startvm "boinc_94ef0a7c3ee918b0" --type headless
Exit Code: -2147467259
Output:
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: AMD-V is disabled in the BIOS (or by the host OS) (VERR_SVM_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole
Waiting for VM "boinc_94ef0a7c3ee918b0" to power on...

2025-01-22 15:02:37 (27908): 
Command: VBoxManage -q snapshot "boinc_94ef0a7c3ee918b0" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2025-01-22 15:02:38 (27908): 
Command: VBoxManage -q bandwidthctl "boinc_94ef0a7c3ee918b0" remove "boinc_94ef0a7c3ee918b0_net" 
Exit Code: 0
Output:
VBoxManage.exe: error: Bandwidth groups cannot be deleted while the VM is running

2025-01-22 15:02:38 (27908): 
Command: VBoxManage -q unregistervm "boinc_94ef0a7c3ee918b0" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

2025-01-22 15:02:43 (27908): called boinc_finish(-2147467259)

</stderr_txt>
]]>


©2025 CERN