Name Theory_2773-2926199-378_0
Workunit 229879481
Created 21 Jan 2025, 11:21:46 UTC
Sent 21 Jan 2025, 16:19:08 UTC
Report deadline 1 Feb 2025, 16:19:08 UTC
Received 21 Jan 2025, 18:52:06 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status -2147467259 (0x80004005) Unknown error code
Computer ID 10693871
Run time 28 sec
CPU time
Validate state Invalid
Credit 0.00
Device peak FLOPS 3.60 GFLOPS
Application version Theory Simulation v300.60 (vbox64_theory)
windows_x86_64
Peak working set size 6.45 MB
Peak swap size 1.76 MB
Peak disk usage 0.87 MB

Stderr output

<core_client_version>8.0.2</core_client_version>
<![CDATA[
<message>
Unspecified error
 (0x80004005) - exit code 2147500037 (0x80004005)</message>
<stderr_txt>
2025-01-21 11:25:15 (5104): vboxwrapper version 26208
2025-01-21 11:25:15 (5104): BOINC client version: 8.0.2
2025-01-21 11:25:16 (5104): Detected: VirtualBox VboxManage Interface (Version: 7.0.6)
2025-01-21 11:25:16 (5104): Detected: Heartbeat check (file: 'heartbeat' every 1200.000000 seconds)
2025-01-21 11:25:16 (5104): Successfully copied 'init_data.xml' to the shared directory.
2025-01-21 11:25:16 (5104): Successfully copied 'input' to the shared directory.
2025-01-21 11:25:16 (5104): Create VM. (boinc_09c0e23c9a188962, slot#4)
2025-01-21 11:25:17 (5104): Setting Memory Size for VM. (630MB)
2025-01-21 11:25:17 (5104): Setting CPU Count for VM. (1)
2025-01-21 11:25:18 (5104): Setting Chipset Options for VM.
2025-01-21 11:25:18 (5104): Setting Graphics Controller Options for VM.
2025-01-21 11:25:18 (5104): Setting Boot Options for VM.
2025-01-21 11:25:18 (5104): Setting Network Configuration for NAT.
2025-01-21 11:25:19 (5104): Enabling VM Network Access.
2025-01-21 11:25:19 (5104): Disabling USB Support for VM.
2025-01-21 11:25:19 (5104): Disabling COM Port Support for VM.
2025-01-21 11:25:19 (5104): Disabling LPT Port Support for VM.
2025-01-21 11:25:20 (5104): Disabling Audio Support for VM.
2025-01-21 11:25:20 (5104): Disabling Clipboard Support for VM.
2025-01-21 11:25:20 (5104): Disabling Drag and Drop Support for VM.
2025-01-21 11:25:21 (5104): Adding storage controller(s) to VM.
2025-01-21 11:25:21 (5104): Adding virtual disk drive to VM. (Theory_2025_01_16_prod.vdi)
2025-01-21 11:25:22 (5104): Adding VirtualBox Guest Additions to VM.
2025-01-21 11:25:22 (5104): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2025-01-21 11:25:22 (5104): forwarding host port 63610 to guest port 80
2025-01-21 11:25:23 (5104): Enabling remote desktop for VM.
2025-01-21 11:25:23 (5104): Required extension pack not installed, remote desktop not enabled.
2025-01-21 11:25:23 (5104): Enabling shared directory for VM.
2025-01-21 11:25:23 (5104): Starting VM using VBoxManage interface. (boinc_09c0e23c9a188962, slot#4)
2025-01-21 11:25:29 (5104): Error in start VM for VM: -2147467259
Command:
VBoxManage -q startvm "boinc_09c0e23c9a188962" --type headless
Output:
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole
Waiting for VM "boinc_09c0e23c9a188962" to power on...

2025-01-21 11:25:29 (5104): VM failed to start.
2025-01-21 11:25:29 (5104): Could not start 
2025-01-21 11:25:29 (5104): ERROR: VM failed to start
2025-01-21 11:25:29 (5104): Powering off VM.
2025-01-21 11:25:29 (5104): Deregistering VM. (boinc_09c0e23c9a188962, slot#4)
2025-01-21 11:25:29 (5104): Removing network bandwidth throttle group from VM.
2025-01-21 11:25:33 (5104): Attempts: 3
2025-01-21 11:25:33 (5104): Removing VM from VirtualBox.

    Hypervisor System Log:

00:00:15.786355          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:16.444034          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_1c09d49129153f04\boinc_1c09d49129153f04.vbox" with version "1.19-windows"
00:00:16.446955          Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_1c09d49129153f04\boinc_1c09d49129153f04.vbox"
00:00:16.449387          Saving settings file "C:\Users\USER\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:16.452909          Finished saving settings file "C:\Users\USER\.VirtualBox\VirtualBox.xml"
00:00:16.454263 DeleteVM Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_09c0e23c9a188962\boinc_09c0e23c9a188962.vbox" with version "1.19-windows"
00:00:16.458156 DeleteVM Finished saving settings file "C:\ProgramData\BOINC\slots\4\boinc_09c0e23c9a188962\boinc_09c0e23c9a188962.vbox"
00:00:16.521444          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:16.579307          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_1c09d49129153f04\boinc_1c09d49129153f04.vbox" with version "1.19-windows"
00:00:16.582984          Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_1c09d49129153f04\boinc_1c09d49129153f04.vbox"
00:00:16.834140          Saving settings file "C:\Users\USER\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:16.837531          Finished saving settings file "C:\Users\USER\.VirtualBox\VirtualBox.xml"
00:00:16.838788 DeleteVM Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_09c0e23c9a188962\boinc_09c0e23c9a188962.vbox" with version "1.19-windows"
00:00:16.841822 DeleteVM Finished saving settings file "C:\ProgramData\BOINC\slots\4\boinc_09c0e23c9a188962\boinc_09c0e23c9a188962.vbox"
00:00:17.094018          Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_4aca1d09c84fc548\boinc_4aca1d09c84fc548.vbox" with version "1.19-windows"
00:00:17.096973          Finished saving settings file "C:\ProgramData\BOINC\slots\7\boinc_4aca1d09c84fc548\boinc_4aca1d09c84fc548.vbox"
00:00:17.163104          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:17.313672          Saving settings file "C:\Users\USER\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:17.316489          Finished saving settings file "C:\Users\USER\.VirtualBox\VirtualBox.xml"
00:00:17.316730          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_feaaef81c406675f\boinc_feaaef81c406675f.vbox" with version "1.19-windows"
00:00:17.319635          Finished saving settings file "C:\ProgramData\BOINC\slots\3\boinc_feaaef81c406675f\boinc_feaaef81c406675f.vbox"
00:00:17.320867 DeleteVM Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_feaaef81c406675f\boinc_feaaef81c406675f.vbox" with version "1.19-windows"
00:00:17.324284 DeleteVM Finished saving settings file "C:\ProgramData\BOINC\slots\3\boinc_feaaef81c406675f\boinc_feaaef81c406675f.vbox"
00:00:18.734087          Saving settings file "C:\ProgramData\BOINC\slots\6\boinc_4438ea5f2c07a0a0\boinc_4438ea5f2c07a0a0.vbox" with version "1.19-windows"
00:00:18.737108          Finished saving settings file "C:\ProgramData\BOINC\slots\6\boinc_4438ea5f2c07a0a0\boinc_4438ea5f2c07a0a0.vbox"
00:00:18.803027          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:18.867438          Saving settings file "C:\ProgramData\BOINC\slots\6\boinc_4438ea5f2c07a0a0\boinc_4438ea5f2c07a0a0.vbox" with version "1.19-windows"
00:00:18.870551          Finished saving settings file "C:\ProgramData\BOINC\slots\6\boinc_4438ea5f2c07a0a0\boinc_4438ea5f2c07a0a0.vbox"
00:00:18.876371          Saving settings file "C:\Users\USER\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:18.879322          Finished saving settings file "C:\Users\USER\.VirtualBox\VirtualBox.xml"
00:00:18.879599          Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_4aca1d09c84fc548\boinc_4aca1d09c84fc548.vbox" with version "1.19-windows"
00:00:18.882753          Finished saving settings file "C:\ProgramData\BOINC\slots\7\boinc_4aca1d09c84fc548\boinc_4aca1d09c84fc548.vbox"
00:00:18.884136 DeleteVM Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_4aca1d09c84fc548\boinc_4aca1d09c84fc548.vbox" with version "1.19-windows"
00:00:18.887761 DeleteVM Finished saving settings file "C:\ProgramData\BOINC\slots\7\boinc_4aca1d09c84fc548\boinc_4aca1d09c84fc548.vbox"
00:00:19.299486          Saving settings file "C:\Users\USER\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:19.304638          Finished saving settings file "C:\Users\USER\.VirtualBox\VirtualBox.xml"
00:00:19.304876          Saving settings file "C:\ProgramData\BOINC\slots\6\boinc_4438ea5f2c07a0a0\boinc_4438ea5f2c07a0a0.vbox" with version "1.19-windows"
00:00:19.307617          Finished saving settings file "C:\ProgramData\BOINC\slots\6\boinc_4438ea5f2c07a0a0\boinc_4438ea5f2c07a0a0.vbox"
00:00:19.308791 DeleteVM Saving settings file "C:\ProgramData\BOINC\slots\6\boinc_4438ea5f2c07a0a0\boinc_4438ea5f2c07a0a0.vbox" with version "1.19-windows"
00:00:19.312075 DeleteVM Finished saving settings file "C:\ProgramData\BOINC\slots\6\boinc_4438ea5f2c07a0a0\boinc_4438ea5f2c07a0a0.vbox"
00:00:19.913898          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_19ac44bbfb7a588b\boinc_19ac44bbfb7a588b.vbox" with version "1.19-windows"
00:00:19.918335          Finished saving settings file "C:\ProgramData\BOINC\slots\2\boinc_19ac44bbfb7a588b\boinc_19ac44bbfb7a588b.vbox"
00:00:19.981607          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:20.040754          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_19ac44bbfb7a588b\boinc_19ac44bbfb7a588b.vbox" with version "1.19-windows"
00:00:20.044974          Finished saving settings file "C:\ProgramData\BOINC\slots\2\boinc_19ac44bbfb7a588b\boinc_19ac44bbfb7a588b.vbox"
00:00:20.302338          Saving settings file "C:\Users\USER\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:20.306848          Finished saving settings file "C:\Users\USER\.VirtualBox\VirtualBox.xml"
00:00:20.307790 DeleteVM Saving settings file "C:\ProgramData\BOINC\slots\6\boinc_4438ea5f2c07a0a0\boinc_4438ea5f2c07a0a0.vbox" with version "1.19-windows"
00:00:20.310635 DeleteVM Finished saving settings file "C:\ProgramData\BOINC\slots\6\boinc_4438ea5f2c07a0a0\boinc_4438ea5f2c07a0a0.vbox"
00:00:21.195955          Saving settings file "C:\Users\USER\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:21.200986          Finished saving settings file "C:\Users\USER\.VirtualBox\VirtualBox.xml"
00:00:21.201157          Saving settings file "C:\Users\USER\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:21.204088          Finished saving settings file "C:\Users\USER\.VirtualBox\VirtualBox.xml"
00:00:21.205070 DeleteVM Saving settings file "C:\Users\USER\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:21.208187 DeleteVM Finished saving settings file "C:\Users\USER\.VirtualBox\VirtualBox.xml"
00:00:26.226088 main     VirtualBox: object deletion starts
00:00:26.227158 main     HostDnsMonitor: shutting down ...
00:00:26.227191 main     HostDnsMonitor: shut down
00:00:26.229009 Watcher  ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0
00:00:26.229191 main     VirtualBox: object deleted

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

           Windows Audio Session
Autostart database path:         
Default Guest Additions ISO:     C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso
Logging Level:                   all
Proxy Mode:                      System
Proxy URL:                       
User language:                   C

2025-01-21 11:25:16 (5104): 
Command: VBoxManage -q list hostinfo 
Exit Code: 0
Output:
Host Information:

Host time: 2025-01-21T16:25:16.513000000Z
Processor online count: 8
Processor count: 8
Processor online core count: 4
Processor core count: 4
Processor supports HW virtualization: no
Processor supports PAE: yes
Processor supports long mode: yes
Processor supports nested paging: no
Processor supports unrestricted guest: no
Processor supports nested HW virtualization: no
Processor supports virt. vmsave/vmload: no
Processor#0 speed: unknown
Processor#0 description: Intel(R) Core(TM) i7-3770 CPU @ 3.40GHz
Processor#1 speed: unknown
Processor#1 description: Intel(R) Core(TM) i7-3770 CPU @ 3.40GHz
Processor#2 speed: unknown
Processor#2 description: Intel(R) Core(TM) i7-3770 CPU @ 3.40GHz
Processor#3 speed: unknown
Processor#3 description: Intel(R) Core(TM) i7-3770 CPU @ 3.40GHz
Processor#4 speed: unknown
Processor#4 description: Intel(R) Core(TM) i7-3770 CPU @ 3.40GHz
Processor#5 speed: unknown
Processor#5 description: Intel(R) Core(TM) i7-3770 CPU @ 3.40GHz
Processor#6 speed: unknown
Processor#6 description: Intel(R) Core(TM) i7-3770 CPU @ 3.40GHz
Processor#7 speed: unknown
Processor#7 description: Intel(R) Core(TM) i7-3770 CPU @ 3.40GHz
Memory size: 16346 MByte
Memory available: 8950 MByte
Operating system: Windows 10
Operating system version: 10.0.19045

2025-01-21 11:25:16 (5104): 
Command: VBoxManage -q showvminfo "boinc_09c0e23c9a188962" --machinereadable 
Exit Code: -2135228415
Output:
VBoxManage.exe: error: Could not find a registered machine named 'boinc_09c0e23c9a188962'
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown
VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 3139 of file VBoxManageInfo.cpp

2025-01-21 11:25:17 (5104): 
Command: VBoxManage -q createvm --name "boinc_09c0e23c9a188962" --basefolder "C:\ProgramData\BOINC\slots\4" --ostype "Linux26_64" --register
Exit Code: 0
Output:
Virtual machine 'boinc_09c0e23c9a188962' is created and registered.
UUID: 49022191-2125-42b7-8ee5-eca1557ae09e
Settings file: 'C:\ProgramData\BOINC\slots\4\boinc_09c0e23c9a188962\boinc_09c0e23c9a188962.vbox'

2025-01-21 11:25:17 (5104): 
Command: VBoxManage -q modifyvm "boinc_09c0e23c9a188962" --description "Theory_2773-2926199-378_0" 
Exit Code: 0
Output:

2025-01-21 11:25:17 (5104): 
Command: VBoxManage -q modifyvm "boinc_09c0e23c9a188962" --memory 630 
Exit Code: 0
Output:

2025-01-21 11:25:18 (5104): 
Command: VBoxManage -q modifyvm "boinc_09c0e23c9a188962" --cpus 1 
Exit Code: 0
Output:

2025-01-21 11:25:18 (5104): 
Command: VBoxManage -q modifyvm "boinc_09c0e23c9a188962" --acpi on --ioapic on --rtcuseutc off 
Exit Code: 0
Output:

2025-01-21 11:25:18 (5104): 
Command: VBoxManage -q modifyvm "boinc_09c0e23c9a188962" --vram 16 --graphicscontroller VBoxVGA 
Exit Code: 0
Output:

2025-01-21 11:25:18 (5104): 
Command: VBoxManage -q modifyvm "boinc_09c0e23c9a188962" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2025-01-21 11:25:19 (5104): 
Command: VBoxManage -q modifyvm "boinc_09c0e23c9a188962" --nic1 nat --natdnsproxy1 on --cableconnected1 off 
Exit Code: 0
Output:

2025-01-21 11:25:19 (5104): 
Command: VBoxManage -q modifyvm "boinc_09c0e23c9a188962" --cableconnected1 on 
Exit Code: 0
Output:

2025-01-21 11:25:19 (5104): 
Command: VBoxManage -q modifyvm "boinc_09c0e23c9a188962" --usb off 
Exit Code: 0
Output:

2025-01-21 11:25:19 (5104): 
Command: VBoxManage -q modifyvm "boinc_09c0e23c9a188962" --uart1 off --uart2 off 
Exit Code: 0
Output:

2025-01-21 11:25:20 (5104): 
Command: VBoxManage -q modifyvm "boinc_09c0e23c9a188962" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2025-01-21 11:25:20 (5104): 
Command: VBoxManage -q modifyvm "boinc_09c0e23c9a188962" --audio-enabled off 
Exit Code: 0
Output:

2025-01-21 11:25:20 (5104): 
Command: VBoxManage -q modifyvm "boinc_09c0e23c9a188962" --clipboard disabled 
Exit Code: 0
Output:

2025-01-21 11:25:21 (5104): 
Command: VBoxManage -q modifyvm "boinc_09c0e23c9a188962" --draganddrop disabled 
Exit Code: 0
Output:

2025-01-21 11:25:21 (5104): 
Command: VBoxManage -q storagectl "boinc_09c0e23c9a188962" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2025-01-21 11:25:21 (5104): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2025_01_16_prod.vdi" 
Exit Code: 0
Output:
UUID:           6a4110e9-e559-4c1c-bfd2-ba6f6aaf4169
Parent UUID:    base
State:          created
Type:           normal (base)
Location:       C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\Theory_2025_01_16_prod.vdi
Storage format: VDI
Format variant: dynamic default
Capacity:       20480 MBytes
Size on disk:   781 MBytes
Encryption:     disabled
Property:       AllocationBlockSize=1048576

2025-01-21 11:25:21 (5104): 
Command: VBoxManage -q storageattach "boinc_09c0e23c9a188962" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2025_01_16_prod.vdi" 
Exit Code: 0
Output:

2025-01-21 11:25:22 (5104): 
Command: VBoxManage -q storageattach "boinc_09c0e23c9a188962" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none 
Exit Code: 0
Output:

2025-01-21 11:25:22 (5104): 
Command: VBoxManage -q storageattach "boinc_09c0e23c9a188962" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2025_01_16_prod.vdi" 
Exit Code: 0
Output:

2025-01-21 11:25:22 (5104): 
Command: VBoxManage -q storageattach "boinc_09c0e23c9a188962" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2025-01-21 11:25:22 (5104): 
Command: VBoxManage -q bandwidthctl "boinc_09c0e23c9a188962" add "boinc_09c0e23c9a188962_net" --type network --limit 1024G 
Exit Code: 0
Output:

2025-01-21 11:25:23 (5104): 
Command: VBoxManage -q modifyvm "boinc_09c0e23c9a188962" --natpf1 ",tcp,127.0.0.1,63610,,80" 
Exit Code: 0
Output:

2025-01-21 11:25:23 (5104): 
Command: VBoxManage -q list extpacks
Exit Code: 0
Output:
Extension Packs: 0

2025-01-21 11:25:23 (5104): 
Command: VBoxManage -q sharedfolder add "boinc_09c0e23c9a188962" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\4/shared"
Exit Code: 0
Output:

2025-01-21 11:25:29 (5104): 
Command: VBoxManage -q startvm "boinc_09c0e23c9a188962" --type headless
Exit Code: -2147467259
Output:
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole
Waiting for VM "boinc_09c0e23c9a188962" to power on...

2025-01-21 11:25:29 (5104): 
Command: VBoxManage -q snapshot "boinc_09c0e23c9a188962" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2025-01-21 11:25:29 (5104): 
Command: VBoxManage -q bandwidthctl "boinc_09c0e23c9a188962" remove "boinc_09c0e23c9a188962_net" 
Exit Code: 0
Output:
VBoxManage.exe: error: Bandwidth groups cannot be deleted while the VM is running

2025-01-21 11:25:33 (5104): 
Command: VBoxManage -q unregistervm "boinc_09c0e23c9a188962" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

2025-01-21 11:25:42 (5104): called boinc_finish(-2147467259)

</stderr_txt>
]]>