Name | Theory_2773-2995838-354_0 |
Workunit | 229864709 |
Created | 20 Jan 2025, 10:41:28 UTC |
Sent | 20 Jan 2025, 15:51:02 UTC |
Report deadline | 31 Jan 2025, 15:51:02 UTC |
Received | 20 Jan 2025, 17:13:44 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | -2147467259 (0x80004005) Unknown error code |
Computer ID | 10820056 |
Run time | 12 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 2.72 GFLOPS |
Application version | Theory Simulation v300.60 (vbox64_theory) windows_x86_64 |
Peak working set size | 11.19 MB |
Peak swap size | 6.25 MB |
Peak disk usage | 1.01 MB |
<core_client_version>7.20.2</core_client_version> <![CDATA[ <message> Unspecified error (0x80004005) - exit code 2147500037 (0x80004005)</message> <stderr_txt> 2025-01-20 10:51:17 (17340): vboxwrapper version 26208 2025-01-20 10:51:17 (17340): BOINC client version: 7.20.2 2025-01-20 10:51:17 (17340): Detected: VirtualBox VboxManage Interface (Version: 6.1.34) 2025-01-20 10:51:17 (17340): Detected: Heartbeat check (file: 'heartbeat' every 1200.000000 seconds) 2025-01-20 10:51:17 (17340): Successfully copied 'init_data.xml' to the shared directory. 2025-01-20 10:51:17 (17340): Successfully copied 'input' to the shared directory. 2025-01-20 10:51:18 (17340): Create VM. (boinc_c06d30e595d336a6, slot#7) 2025-01-20 10:51:18 (17340): Setting Memory Size for VM. (630MB) 2025-01-20 10:51:19 (17340): Setting CPU Count for VM. (1) 2025-01-20 10:51:19 (17340): Setting Chipset Options for VM. 2025-01-20 10:51:19 (17340): Setting Graphics Controller Options for VM. 2025-01-20 10:51:19 (17340): Setting Boot Options for VM. 2025-01-20 10:51:20 (17340): Setting Network Configuration for NAT. 2025-01-20 10:51:20 (17340): Enabling VM Network Access. 2025-01-20 10:51:20 (17340): Disabling USB Support for VM. 2025-01-20 10:51:20 (17340): Disabling COM Port Support for VM. 2025-01-20 10:51:21 (17340): Disabling LPT Port Support for VM. 2025-01-20 10:51:21 (17340): Disabling Audio Support for VM. 2025-01-20 10:51:21 (17340): Disabling Clipboard Support for VM. 2025-01-20 10:51:21 (17340): Disabling Drag and Drop Support for VM. 2025-01-20 10:51:22 (17340): Adding storage controller(s) to VM. 2025-01-20 10:51:22 (17340): Adding virtual disk drive to VM. (Theory_2025_01_16_prod.vdi) 2025-01-20 10:51:23 (17340): Adding VirtualBox Guest Additions to VM. 2025-01-20 10:51:23 (17340): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2025-01-20 10:51:23 (17340): forwarding host port 50720 to guest port 80 2025-01-20 10:51:24 (17340): Enabling remote desktop for VM. 2025-01-20 10:51:24 (17340): Required extension pack not installed, remote desktop not enabled. 2025-01-20 10:51:24 (17340): Enabling shared directory for VM. 2025-01-20 10:51:25 (17340): Starting VM using VBoxManage interface. (boinc_c06d30e595d336a6, slot#7) 2025-01-20 10:51:31 (17340): Error in start VM for VM: -2147467259 Command: VBoxManage -q startvm "boinc_c06d30e595d336a6" --type headless Output: Waiting for VM "boinc_c06d30e595d336a6" to power on... VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole 2025-01-20 10:51:31 (17340): VM failed to start. 2025-01-20 10:51:31 (17340): Could not start 2025-01-20 10:51:31 (17340): ERROR: VM failed to start 2025-01-20 10:51:31 (17340): Powering off VM. 2025-01-20 10:51:31 (17340): Deregistering VM. (boinc_c06d30e595d336a6, slot#7) 2025-01-20 10:51:31 (17340): Removing network bandwidth throttle group from VM. 2025-01-20 10:51:31 (17340): Removing VM from VirtualBox. Hypervisor System Log: 00:00:16.800661 Saving settings file "C:\ProgramData\BOINC\slots\6\boinc_d00e961663569882\boinc_d00e961663569882.vbox" with version "1.16-windows" 00:00:16.962305 Launched VM: 65618352 pid: 14520 (0x38b8) frontend: headless name: boinc_c06d30e595d336a6 00:00:17.117577 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:17.117814 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:17.129330 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:17.140288 Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_e929c1a6b6328ac3\boinc_e929c1a6b6328ac3.vbox" with version "1.16-windows" 00:00:17.314806 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:17.396933 Launched VM: 65617984 pid: 20972 (0x51ec) frontend: headless name: boinc_d00e961663569882 00:00:17.462732 Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_e929c1a6b6328ac3\boinc_e929c1a6b6328ac3.vbox" with version "1.16-windows" 00:00:17.697812 Saving settings file "C:\Users\Jeremy\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:17.705190 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_83fa013bf9ad5157\boinc_83fa013bf9ad5157.vbox" with version "1.16-windows" 00:00:17.713596 DeleteVM Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_83fa013bf9ad5157\boinc_83fa013bf9ad5157.vbox" with version "1.16-windows" 00:00:18.207838 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_83fa013bf9ad5157\boinc_83fa013bf9ad5157.vbox" with version "1.16-windows" 00:00:18.349604 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:18.458365 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_83fa013bf9ad5157\boinc_83fa013bf9ad5157.vbox" with version "1.16-windows" 00:00:18.715047 Saving settings file "C:\Users\Jeremy\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:18.722239 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_90cb720909c6be25\boinc_90cb720909c6be25.vbox" with version "1.16-windows" 00:00:18.730619 DeleteVM Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_90cb720909c6be25\boinc_90cb720909c6be25.vbox" with version "1.16-windows" 00:00:18.937230 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_90cb720909c6be25\boinc_90cb720909c6be25.vbox" with version "1.16-windows" 00:00:19.056027 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:19.160943 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_90cb720909c6be25\boinc_90cb720909c6be25.vbox" with version "1.16-windows" 00:00:19.428240 Saving settings file "C:\Users\Jeremy\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:19.435085 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_048b1606fbc6f5b9\boinc_048b1606fbc6f5b9.vbox" with version "1.16-windows" 00:00:19.443796 DeleteVM Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_048b1606fbc6f5b9\boinc_048b1606fbc6f5b9.vbox" with version "1.16-windows" 00:00:20.044927 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_048b1606fbc6f5b9\boinc_048b1606fbc6f5b9.vbox" with version "1.16-windows" 00:00:20.194452 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:20.306140 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_048b1606fbc6f5b9\boinc_048b1606fbc6f5b9.vbox" with version "1.16-windows" 00:00:20.560948 Saving settings file "C:\Users\Jeremy\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:20.569728 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_f16a28e3a796cb00\boinc_f16a28e3a796cb00.vbox" with version "1.16-windows" 00:00:20.580933 DeleteVM Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_f16a28e3a796cb00\boinc_f16a28e3a796cb00.vbox" with version "1.16-windows" 00:00:21.535259 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_f16a28e3a796cb00\boinc_f16a28e3a796cb00.vbox" with version "1.16-windows" 00:00:21.670120 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:21.770622 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_f16a28e3a796cb00\boinc_f16a28e3a796cb00.vbox" with version "1.16-windows" 00:00:22.025604 Saving settings file "C:\Users\Jeremy\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:22.032138 Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_c06d30e595d336a6\boinc_c06d30e595d336a6.vbox" with version "1.16-windows" 00:00:22.041162 DeleteVM Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_c06d30e595d336a6\boinc_c06d30e595d336a6.vbox" with version "1.16-windows" 00:00:23.064564 Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_c06d30e595d336a6\boinc_c06d30e595d336a6.vbox" with version "1.16-windows" 00:00:23.186307 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:23.287989 Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_c06d30e595d336a6\boinc_c06d30e595d336a6.vbox" with version "1.16-windows" 00:00:23.504432 Saving settings file "C:\ProgramData\BOINC\slots\6\boinc_d00e961663569882\boinc_d00e961663569882.vbox" with version "1.16-windows" 00:00:23.540202 Saving settings file "C:\Users\Jeremy\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:23.546242 Saving settings file "C:\ProgramData\BOINC\slots\6\boinc_d00e961663569882\boinc_d00e961663569882.vbox" with version "1.16-windows" 00:00:23.554575 DeleteVM Saving settings file "C:\ProgramData\BOINC\slots\6\boinc_d00e961663569882\boinc_d00e961663569882.vbox" with version "1.16-windows" 00:00:23.627702 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:23.726379 Saving settings file "C:\ProgramData\BOINC\slots\6\boinc_d00e961663569882\boinc_d00e961663569882.vbox" with version "1.16-windows" 00:00:23.975200 Saving settings file "C:\Users\Jeremy\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:28.995706 main VirtualBox: object deletion starts 00:00:28.996491 main HostDnsMonitor: shutting down ... 00:00:28.996523 main HostDnsMonitor: shut down 00:00:28.997801 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:28.998031 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: lt hard disk format: VDI VRDE auth library: VBoxAuth Webservice auth. library: VBoxAuth Remote desktop ExtPack: Log history count: 3 Default frontend: Default audio driver: DirectSound Autostart database path: Default Guest Additions ISO: C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso Logging Level: all Proxy Mode: System Proxy URL: 2025-01-20 10:51:17 (17340): Command: VBoxManage -q list hostinfo Exit Code: 0 Output: Host Information: Host time: 2025-01-20T15:51:17.783000000Z Processor online count: 8 Processor count: 8 Processor online core count: 4 Processor core count: 4 Processor supports HW virtualization: no Processor supports PAE: yes Processor supports long mode: yes Processor supports nested paging: no Processor supports unrestricted guest: no Processor supports nested HW virtualization: no Processor#0 speed: unknown Processor#0 description: Intel(R) Core(TM) i7 CPU 920 @ 2.67GHz Processor#1 speed: unknown Processor#1 description: Intel(R) Core(TM) i7 CPU 920 @ 2.67GHz Processor#2 speed: unknown Processor#2 description: Intel(R) Core(TM) i7 CPU 920 @ 2.67GHz Processor#3 speed: unknown Processor#3 description: Intel(R) Core(TM) i7 CPU 920 @ 2.67GHz Processor#4 speed: unknown Processor#4 description: Intel(R) Core(TM) i7 CPU 920 @ 2.67GHz Processor#5 speed: unknown Processor#5 description: Intel(R) Core(TM) i7 CPU 920 @ 2.67GHz Processor#6 speed: unknown Processor#6 description: Intel(R) Core(TM) i7 CPU 920 @ 2.67GHz Processor#7 speed: unknown Processor#7 description: Intel(R) Core(TM) i7 CPU 920 @ 2.67GHz Memory size: 12279 MByte Memory available: 5943 MByte Operating system: Windows 10 Operating system version: 10.0.19045 2025-01-20 10:51:18 (17340): Command: VBoxManage -q showvminfo "boinc_c06d30e595d336a6" --machinereadable Exit Code: -2135228415 Output: VBoxManage.exe: error: Could not find a registered machine named 'boinc_c06d30e595d336a6' VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2733 of file VBoxManageInfo.cpp 2025-01-20 10:51:18 (17340): Command: VBoxManage -q createvm --name "boinc_c06d30e595d336a6" --basefolder "C:\ProgramData\BOINC\slots\7" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_c06d30e595d336a6' is created and registered. UUID: 312e781b-01a8-4885-a2b0-f86934e77f1d Settings file: 'C:\ProgramData\BOINC\slots\7\boinc_c06d30e595d336a6\boinc_c06d30e595d336a6.vbox' 2025-01-20 10:51:18 (17340): Command: VBoxManage -q modifyvm "boinc_c06d30e595d336a6" --description "Theory_2773-2995838-354_0" Exit Code: 0 Output: 2025-01-20 10:51:19 (17340): Command: VBoxManage -q modifyvm "boinc_c06d30e595d336a6" --memory 630 Exit Code: 0 Output: 2025-01-20 10:51:19 (17340): Command: VBoxManage -q modifyvm "boinc_c06d30e595d336a6" --cpus 1 Exit Code: 0 Output: 2025-01-20 10:51:19 (17340): Command: VBoxManage -q modifyvm "boinc_c06d30e595d336a6" --acpi on --ioapic on --rtcuseutc off Exit Code: 0 Output: 2025-01-20 10:51:19 (17340): Command: VBoxManage -q modifyvm "boinc_c06d30e595d336a6" --vram 16 --graphicscontroller VBoxVGA Exit Code: 0 Output: 2025-01-20 10:51:20 (17340): Command: VBoxManage -q modifyvm "boinc_c06d30e595d336a6" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2025-01-20 10:51:20 (17340): Command: VBoxManage -q modifyvm "boinc_c06d30e595d336a6" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2025-01-20 10:51:20 (17340): Command: VBoxManage -q modifyvm "boinc_c06d30e595d336a6" --cableconnected1 on Exit Code: 0 Output: 2025-01-20 10:51:20 (17340): Command: VBoxManage -q modifyvm "boinc_c06d30e595d336a6" --usb off Exit Code: 0 Output: 2025-01-20 10:51:21 (17340): Command: VBoxManage -q modifyvm "boinc_c06d30e595d336a6" --uart1 off --uart2 off Exit Code: 0 Output: 2025-01-20 10:51:21 (17340): Command: VBoxManage -q modifyvm "boinc_c06d30e595d336a6" --lpt1 off --lpt2 off Exit Code: 0 Output: 2025-01-20 10:51:21 (17340): Command: VBoxManage -q modifyvm "boinc_c06d30e595d336a6" --audio none Exit Code: 0 Output: 2025-01-20 10:51:21 (17340): Command: VBoxManage -q modifyvm "boinc_c06d30e595d336a6" --clipboard disabled Exit Code: 0 Output: 2025-01-20 10:51:22 (17340): Command: VBoxManage -q modifyvm "boinc_c06d30e595d336a6" --draganddrop disabled Exit Code: 0 Output: 2025-01-20 10:51:22 (17340): Command: VBoxManage -q storagectl "boinc_c06d30e595d336a6" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2025-01-20 10:51:22 (17340): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2025_01_16_prod.vdi" Exit Code: 0 Output: UUID: 6a4110e9-e559-4c1c-bfd2-ba6f6aaf4169 Parent UUID: base State: created Type: multiattach Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\Theory_2025_01_16_prod.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 781 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 Child UUIDs: ee8f433f-beeb-4681-a30d-54a1e945e584 c73a45fb-0ee1-4a7f-b5f0-2b3690ba1050 40270f8b-0e8d-4533-924a-a96966127d46 df50fb83-941d-4683-bb69-8077b02a4416 63baccc1-26d1-4c9a-829c-fc0937de0e0f 6a78aa84-e270-4430-a2b5-84efedda517a 2025-01-20 10:51:23 (17340): Command: VBoxManage -q storageattach "boinc_c06d30e595d336a6" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2025_01_16_prod.vdi" Exit Code: 0 Output: 2025-01-20 10:51:23 (17340): Command: VBoxManage -q storageattach "boinc_c06d30e595d336a6" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2025-01-20 10:51:23 (17340): Command: VBoxManage -q bandwidthctl "boinc_c06d30e595d336a6" add "boinc_c06d30e595d336a6_net" --type network --limit 1024G Exit Code: 0 Output: 2025-01-20 10:51:24 (17340): Command: VBoxManage -q modifyvm "boinc_c06d30e595d336a6" --natpf1 ",tcp,127.0.0.1,50720,,80" Exit Code: 0 Output: 2025-01-20 10:51:24 (17340): Command: VBoxManage -q list extpacks Exit Code: 0 Output: Extension Packs: 0 2025-01-20 10:51:24 (17340): Command: VBoxManage -q sharedfolder add "boinc_c06d30e595d336a6" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\7/shared" Exit Code: 0 Output: 2025-01-20 10:51:31 (17340): Command: VBoxManage -q startvm "boinc_c06d30e595d336a6" --type headless Exit Code: -2147467259 Output: Waiting for VM "boinc_c06d30e595d336a6" to power on... VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole 2025-01-20 10:51:31 (17340): Command: VBoxManage -q snapshot "boinc_c06d30e595d336a6" list Exit Code: -108 Output: This machine does not have any snapshots 2025-01-20 10:51:31 (17340): Command: VBoxManage -q bandwidthctl "boinc_c06d30e595d336a6" remove "boinc_c06d30e595d336a6_net" Exit Code: 0 Output: 2025-01-20 10:51:31 (17340): Command: VBoxManage -q unregistervm "boinc_c06d30e595d336a6" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 2025-01-20 10:51:38 (17340): called boinc_finish(-2147467259) </stderr_txt> ]]>
©2025 CERN