Name | Theory_2794-3261158-179_1 |
Workunit | 225917634 |
Created | 9 Oct 2024, 20:03:33 UTC |
Sent | 10 Oct 2024, 12:12:52 UTC |
Report deadline | 21 Oct 2024, 12:12:52 UTC |
Received | 10 Oct 2024, 12:35:14 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | -2147467259 (0x80004005) Unknown error code |
Computer ID | 10844799 |
Run time | 9 sec |
CPU time | 0 sec |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 4.22 GFLOPS |
Application version | Theory Simulation v300.30 (vbox64_theory) windows_x86_64 |
Peak working set size | 10.35 MB |
Peak swap size | 4.53 MB |
Peak disk usage | 2.03 MB |
<core_client_version>8.0.2</core_client_version> <![CDATA[ <message> Unspecified error (0x80004005) - exit code 2147500037 (0x80004005)</message> <stderr_txt> 2024-10-10 08:33:20 (9980): vboxwrapper version 26207 2024-10-10 08:33:20 (9980): BOINC client version: 8.0.2 2024-10-10 08:33:22 (9980): Detected: VirtualBox VboxManage Interface (Version: 6.1.12) 2024-10-10 08:33:22 (9980): Detected: Heartbeat check (file: 'heartbeat' every 1200.000000 seconds) 2024-10-10 08:33:22 (9980): Successfully copied 'init_data.xml' to the shared directory. 2024-10-10 08:33:22 (9980): Successfully copied 'input' to the shared directory. 2024-10-10 08:33:23 (9980): Create VM. (boinc_213d81e321e70b22, slot#7) 2024-10-10 08:33:23 (9980): Setting Memory Size for VM. (630MB) 2024-10-10 08:33:24 (9980): Setting CPU Count for VM. (1) 2024-10-10 08:33:24 (9980): Setting Chipset Options for VM. 2024-10-10 08:33:24 (9980): Setting Graphics Controller Options for VM. 2024-10-10 08:33:25 (9980): Setting Boot Options for VM. 2024-10-10 08:33:25 (9980): Setting Network Configuration for NAT. 2024-10-10 08:33:25 (9980): Enabling VM Network Access. 2024-10-10 08:33:26 (9980): Disabling USB Support for VM. 2024-10-10 08:33:26 (9980): Disabling COM Port Support for VM. 2024-10-10 08:33:26 (9980): Disabling LPT Port Support for VM. 2024-10-10 08:33:27 (9980): Disabling Audio Support for VM. 2024-10-10 08:33:27 (9980): Disabling Clipboard Support for VM. 2024-10-10 08:33:27 (9980): Disabling Drag and Drop Support for VM. 2024-10-10 08:33:28 (9980): Adding storage controller(s) to VM. 2024-10-10 08:33:28 (9980): Adding virtual disk drive to VM. (Theory_2024_04_30_prod.vdi) 2024-10-10 08:33:30 (9980): Adding VirtualBox Guest Additions to VM. 2024-10-10 08:33:30 (9980): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2024-10-10 08:33:30 (9980): forwarding host port 49448 to guest port 80 2024-10-10 08:33:31 (9980): Enabling remote desktop for VM. 2024-10-10 08:33:31 (9980): Required extension pack not installed, remote desktop not enabled. 2024-10-10 08:33:31 (9980): Enabling shared directory for VM. 2024-10-10 08:33:32 (9980): Starting VM using VBoxManage interface. (boinc_213d81e321e70b22, slot#7) 2024-10-10 08:33:38 (9980): Error in start VM for VM: -2147467259 Command: VBoxManage -q startvm "boinc_213d81e321e70b22" --type headless Output: Waiting for VM "boinc_213d81e321e70b22" to power on... VBoxManage.exe: error: The native API dll was not found (C:\Windows\system32\WinHvPlatform.dll) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole 2024-10-10 08:33:38 (9980): VM failed to start. 2024-10-10 08:33:38 (9980): Could not start 2024-10-10 08:33:38 (9980): ERROR: VM failed to start 2024-10-10 08:33:38 (9980): Powering off VM. 2024-10-10 08:33:38 (9980): Deregistering VM. (boinc_213d81e321e70b22, slot#7) 2024-10-10 08:33:38 (9980): Removing network bandwidth throttle group from VM. 2024-10-10 08:33:38 (9980): Removing VM from VirtualBox. Hypervisor System Log: 00:00:01.659813 Saving settings file "C:\Users\Zarchon\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:01.956702 Saving settings file "E:\ProgramFiles\BOINC\DataFiles\slots\7\boinc_213d81e321e70b22\boinc_213d81e321e70b22.vbox" with version "1.16-windows" 00:00:02.284843 Saving settings file "E:\ProgramFiles\BOINC\DataFiles\slots\7\boinc_213d81e321e70b22\boinc_213d81e321e70b22.vbox" with version "1.16-windows" 00:00:02.628609 Saving settings file "E:\ProgramFiles\BOINC\DataFiles\slots\7\boinc_213d81e321e70b22\boinc_213d81e321e70b22.vbox" with version "1.16-windows" 00:00:02.972375 Saving settings file "E:\ProgramFiles\BOINC\DataFiles\slots\7\boinc_213d81e321e70b22\boinc_213d81e321e70b22.vbox" with version "1.16-windows" 00:00:03.316141 Saving settings file "E:\ProgramFiles\BOINC\DataFiles\slots\7\boinc_213d81e321e70b22\boinc_213d81e321e70b22.vbox" with version "1.16-windows" 00:00:03.675533 Saving settings file "E:\ProgramFiles\BOINC\DataFiles\slots\7\boinc_213d81e321e70b22\boinc_213d81e321e70b22.vbox" with version "1.16-windows" 00:00:04.034926 Saving settings file "E:\ProgramFiles\BOINC\DataFiles\slots\7\boinc_213d81e321e70b22\boinc_213d81e321e70b22.vbox" with version "1.16-windows" 00:00:04.378746 Saving settings file "E:\ProgramFiles\BOINC\DataFiles\slots\7\boinc_213d81e321e70b22\boinc_213d81e321e70b22.vbox" with version "1.16-windows" 00:00:04.722512 Saving settings file "E:\ProgramFiles\BOINC\DataFiles\slots\7\boinc_213d81e321e70b22\boinc_213d81e321e70b22.vbox" with version "1.16-windows" 00:00:05.067935 Saving settings file "E:\ProgramFiles\BOINC\DataFiles\slots\7\boinc_213d81e321e70b22\boinc_213d81e321e70b22.vbox" with version "1.16-windows" 00:00:05.411703 Saving settings file "E:\ProgramFiles\BOINC\DataFiles\slots\7\boinc_213d81e321e70b22\boinc_213d81e321e70b22.vbox" with version "1.16-windows" 00:00:05.817972 Saving settings file "E:\ProgramFiles\BOINC\DataFiles\slots\7\boinc_213d81e321e70b22\boinc_213d81e321e70b22.vbox" with version "1.16-windows" 00:00:06.177364 Saving settings file "E:\ProgramFiles\BOINC\DataFiles\slots\7\boinc_213d81e321e70b22\boinc_213d81e321e70b22.vbox" with version "1.16-windows" 00:00:06.536756 Saving settings file "E:\ProgramFiles\BOINC\DataFiles\slots\7\boinc_213d81e321e70b22\boinc_213d81e321e70b22.vbox" with version "1.16-windows" 00:00:06.896147 Saving settings file "E:\ProgramFiles\BOINC\DataFiles\slots\7\boinc_213d81e321e70b22\boinc_213d81e321e70b22.vbox" with version "1.16-windows" 00:00:07.614933 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.614933 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.614933 Saving settings file "C:\Users\Zarchon\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:07.614933 Saving settings file "E:\ProgramFiles\BOINC\DataFiles\slots\7\boinc_213d81e321e70b22\boinc_213d81e321e70b22.vbox" with version "1.16-windows" 00:00:07.911822 Saving settings file "E:\ProgramFiles\BOINC\DataFiles\slots\7\boinc_213d81e321e70b22\boinc_213d81e321e70b22.vbox" with version "1.16-windows" 00:00:08.255588 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.255588 Saving settings file "E:\ProgramFiles\BOINC\DataFiles\slots\7\boinc_213d81e321e70b22\boinc_213d81e321e70b22.vbox" with version "1.16-windows" 00:00:08.271213 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.271213 Saving settings file "E:\ProgramFiles\BOINC\DataFiles\slots\7\boinc_213d81e321e70b22\boinc_213d81e321e70b22.vbox" with version "1.16-windows" 00:00:08.271213 Saving settings file "E:\ProgramFiles\BOINC\DataFiles\slots\7\boinc_213d81e321e70b22\boinc_213d81e321e70b22.vbox" with version "1.16-windows" 00:00:08.630605 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.630605 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.630605 Saving settings file "C:\Users\Zarchon\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:08.646232 Saving settings file "C:\Users\Zarchon\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:08.646232 Saving settings file "E:\ProgramFiles\BOINC\DataFiles\slots\7\boinc_213d81e321e70b22\boinc_213d81e321e70b22.vbox" with version "1.16-windows" 00:00:08.989998 Saving settings file "E:\ProgramFiles\BOINC\DataFiles\slots\7\boinc_213d81e321e70b22\boinc_213d81e321e70b22.vbox" with version "1.16-windows" 00:00:09.318265 Saving settings file "E:\ProgramFiles\BOINC\DataFiles\slots\7\boinc_213d81e321e70b22\boinc_213d81e321e70b22.vbox" with version "1.16-windows" 00:00:09.990170 Saving settings file "E:\ProgramFiles\BOINC\DataFiles\slots\7\boinc_213d81e321e70b22\boinc_213d81e321e70b22.vbox" with version "1.16-windows" 00:00:10.333938 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:10.333938 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:10.349564 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:10.802710 Launched VM: 85091920 pid: 10076 (0x275c) frontend: headless name: boinc_213d81e321e70b22 00:00:16.350082 Saving settings file "E:\ProgramFiles\BOINC\DataFiles\slots\7\boinc_213d81e321e70b22\boinc_213d81e321e70b22.vbox" with version "1.16-windows" 00:00:16.496717 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:16.870911 Saving settings file "C:\Users\Zarchon\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:21.886923 main VirtualBox: object deletion starts 00:00:21.886923 main HostDnsMonitor: shutting down ... 00:00:21.886923 main HostDnsMonitor: shut down 00:00:21.886923 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:21.886923 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: Default audio driver: DirectSound Autostart database path: Default Guest Additions ISO: E:\ProgramFiles/VBoxGuestAdditions.iso Logging Level: all Proxy Mode: System Proxy URL: 2024-10-10 08:33:22 (9980): Command: VBoxManage -q list hostinfo Exit Code: 0 Output: Host Information: Host time: 2024-10-10T12:33:22.506000000Z Processor online count: 8 Processor count: 8 Processor online core count: 4 Processor core count: 4 Processor supports HW virtualization: no Processor supports PAE: yes Processor supports long mode: yes Processor supports nested paging: no Processor supports unrestricted guest: no Processor supports nested HW virtualization: no Processor#0 speed: unknown Processor#0 description: Intel(R) Core(TM) i7-3770 CPU @ 3.40GHz Processor#1 speed: unknown Processor#1 description: Intel(R) Core(TM) i7-3770 CPU @ 3.40GHz Processor#2 speed: unknown Processor#2 description: Intel(R) Core(TM) i7-3770 CPU @ 3.40GHz Processor#3 speed: unknown Processor#3 description: Intel(R) Core(TM) i7-3770 CPU @ 3.40GHz Processor#4 speed: unknown Processor#4 description: Intel(R) Core(TM) i7-3770 CPU @ 3.40GHz Processor#5 speed: unknown Processor#5 description: Intel(R) Core(TM) i7-3770 CPU @ 3.40GHz Processor#6 speed: unknown Processor#6 description: Intel(R) Core(TM) i7-3770 CPU @ 3.40GHz Processor#7 speed: unknown Processor#7 description: Intel(R) Core(TM) i7-3770 CPU @ 3.40GHz Memory size: 10195 MByte Memory available: 5148 MByte Operating system: Windows 8.1 Operating system version: 6.3.9600 2024-10-10 08:33:23 (9980): Command: VBoxManage -q showvminfo "boinc_213d81e321e70b22" --machinereadable Exit Code: -2135228415 Output: VBoxManage.exe: error: Could not find a registered machine named 'boinc_213d81e321e70b22' VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2715 of file VBoxManageInfo.cpp 2024-10-10 08:33:23 (9980): Command: VBoxManage -q createvm --name "boinc_213d81e321e70b22" --basefolder "E:\ProgramFiles\BOINC\DataFiles\slots\7" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_213d81e321e70b22' is created and registered. UUID: 0d8bdf63-213f-4eaa-81c2-e68d0c8b8411 Settings file: 'E:\ProgramFiles\BOINC\DataFiles\slots\7\boinc_213d81e321e70b22\boinc_213d81e321e70b22.vbox' 2024-10-10 08:33:23 (9980): Command: VBoxManage -q modifyvm "boinc_213d81e321e70b22" --description "Theory_2794-3261158-179_1" Exit Code: 0 Output: 2024-10-10 08:33:24 (9980): Command: VBoxManage -q modifyvm "boinc_213d81e321e70b22" --memory 630 Exit Code: 0 Output: 2024-10-10 08:33:24 (9980): Command: VBoxManage -q modifyvm "boinc_213d81e321e70b22" --cpus 1 Exit Code: 0 Output: 2024-10-10 08:33:24 (9980): Command: VBoxManage -q modifyvm "boinc_213d81e321e70b22" --acpi on --ioapic on --rtcuseutc off Exit Code: 0 Output: 2024-10-10 08:33:25 (9980): Command: VBoxManage -q modifyvm "boinc_213d81e321e70b22" --vram 16 --graphicscontroller VBoxVGA Exit Code: 0 Output: 2024-10-10 08:33:25 (9980): Command: VBoxManage -q modifyvm "boinc_213d81e321e70b22" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2024-10-10 08:33:25 (9980): Command: VBoxManage -q modifyvm "boinc_213d81e321e70b22" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2024-10-10 08:33:26 (9980): Command: VBoxManage -q modifyvm "boinc_213d81e321e70b22" --cableconnected1 on Exit Code: 0 Output: 2024-10-10 08:33:26 (9980): Command: VBoxManage -q modifyvm "boinc_213d81e321e70b22" --usb off Exit Code: 0 Output: 2024-10-10 08:33:26 (9980): Command: VBoxManage -q modifyvm "boinc_213d81e321e70b22" --uart1 off --uart2 off Exit Code: 0 Output: 2024-10-10 08:33:27 (9980): Command: VBoxManage -q modifyvm "boinc_213d81e321e70b22" --lpt1 off --lpt2 off Exit Code: 0 Output: 2024-10-10 08:33:27 (9980): Command: VBoxManage -q modifyvm "boinc_213d81e321e70b22" --audio none Exit Code: 0 Output: 2024-10-10 08:33:27 (9980): Command: VBoxManage -q modifyvm "boinc_213d81e321e70b22" --clipboard disabled Exit Code: 0 Output: 2024-10-10 08:33:28 (9980): Command: VBoxManage -q modifyvm "boinc_213d81e321e70b22" --draganddrop disabled Exit Code: 0 Output: 2024-10-10 08:33:28 (9980): Command: VBoxManage -q storagectl "boinc_213d81e321e70b22" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2024-10-10 08:33:29 (9980): Command: VBoxManage -q showhdinfo "E:\ProgramFiles\BOINC\DataFiles/projects/lhcathome.cern.ch_lhcathome/Theory_2024_04_30_prod.vdi" Exit Code: 0 Output: UUID: 3bbae7b0-9837-4992-8ac4-5c7feef1de80 Parent UUID: base State: created Type: normal (base) Location: E:\ProgramFiles\BOINC\DataFiles\projects\lhcathome.cern.ch_lhcathome\Theory_2024_04_30_prod.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 781 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2024-10-10 08:33:29 (9980): Command: VBoxManage -q storageattach "boinc_213d81e321e70b22" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "E:\ProgramFiles\BOINC\DataFiles/projects/lhcathome.cern.ch_lhcathome/Theory_2024_04_30_prod.vdi" Exit Code: 0 Output: 2024-10-10 08:33:29 (9980): Command: VBoxManage -q storageattach "boinc_213d81e321e70b22" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none Exit Code: 0 Output: 2024-10-10 08:33:30 (9980): Command: VBoxManage -q storageattach "boinc_213d81e321e70b22" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "E:\ProgramFiles\BOINC\DataFiles/projects/lhcathome.cern.ch_lhcathome/Theory_2024_04_30_prod.vdi" Exit Code: 0 Output: 2024-10-10 08:33:30 (9980): Command: VBoxManage -q storageattach "boinc_213d81e321e70b22" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "E:\ProgramFiles/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2024-10-10 08:33:30 (9980): Command: VBoxManage -q bandwidthctl "boinc_213d81e321e70b22" add "boinc_213d81e321e70b22_net" --type network --limit 1024G Exit Code: 0 Output: 2024-10-10 08:33:31 (9980): Command: VBoxManage -q modifyvm "boinc_213d81e321e70b22" --natpf1 ",tcp,127.0.0.1,49448,,80" Exit Code: 0 Output: 2024-10-10 08:33:31 (9980): Command: VBoxManage -q list extpacks Exit Code: 0 Output: Extension Packs: 0 2024-10-10 08:33:31 (9980): Command: VBoxManage -q sharedfolder add "boinc_213d81e321e70b22" --name "shared" --hostpath "E:\ProgramFiles\BOINC\DataFiles\slots\7/shared" Exit Code: 0 Output: 2024-10-10 08:33:37 (9980): Command: VBoxManage -q startvm "boinc_213d81e321e70b22" --type headless Exit Code: -2147467259 Output: Waiting for VM "boinc_213d81e321e70b22" to power on... VBoxManage.exe: error: The native API dll was not found (C:\Windows\system32\WinHvPlatform.dll) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole 2024-10-10 08:33:38 (9980): Command: VBoxManage -q snapshot "boinc_213d81e321e70b22" list Exit Code: -108 Output: This machine does not have any snapshots 2024-10-10 08:33:38 (9980): Command: VBoxManage -q bandwidthctl "boinc_213d81e321e70b22" remove "boinc_213d81e321e70b22_net" Exit Code: 0 Output: VBoxManage.exe: error: Bandwidth groups cannot be deleted while the VM is running 2024-10-10 08:33:38 (9980): Command: VBoxManage -q unregistervm "boinc_213d81e321e70b22" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 2024-10-10 08:33:43 (9980): called boinc_finish(-2147467259) </stderr_txt> ]]>
©2024 CERN