Name | Theory_2743-2730296-291_1 |
Workunit | 223882995 |
Created | 4 Jul 2024, 0:33:21 UTC |
Sent | 4 Jul 2024, 3:15:07 UTC |
Report deadline | 15 Jul 2024, 3:15:07 UTC |
Received | 4 Jul 2024, 4:16:07 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | -2147467259 (0x80004005) Unknown error code |
Computer ID | 10804255 |
Run time | 24 sec |
CPU time | 0 sec |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 3.42 GFLOPS |
Application version | Theory Simulation v300.30 (vbox64_theory) windows_x86_64 |
Peak working set size | 9.45 MB |
Peak swap size | 5.04 MB |
Peak disk usage | 2.03 MB |
<core_client_version>7.24.1</core_client_version> <![CDATA[ <message> - exit code 2147500037 (0x80004005)</message> <stderr_txt> 2024-07-04 04:15:13 (1700): vboxwrapper version 26207 2024-07-04 04:15:13 (1700): BOINC client version: 7.24.1 2024-07-04 04:15:14 (1700): Detected: VirtualBox VboxManage Interface (Version: 6.1.12) 2024-07-04 04:15:14 (1700): Detected: Heartbeat check (file: 'heartbeat' every 1200.000000 seconds) 2024-07-04 04:15:14 (1700): Successfully copied 'init_data.xml' to the shared directory. 2024-07-04 04:15:14 (1700): Successfully copied 'input' to the shared directory. 2024-07-04 04:15:15 (1700): Create VM. (boinc_1288bd1b5007bc86, slot#4) 2024-07-04 04:15:15 (1700): Setting Memory Size for VM. (630MB) 2024-07-04 04:15:16 (1700): Setting CPU Count for VM. (1) 2024-07-04 04:15:16 (1700): Setting Chipset Options for VM. 2024-07-04 04:15:16 (1700): Setting Graphics Controller Options for VM. 2024-07-04 04:15:17 (1700): Setting Boot Options for VM. 2024-07-04 04:15:17 (1700): Setting Network Configuration for NAT. 2024-07-04 04:15:17 (1700): Enabling VM Network Access. 2024-07-04 04:15:17 (1700): Disabling USB Support for VM. 2024-07-04 04:15:18 (1700): Disabling COM Port Support for VM. 2024-07-04 04:15:18 (1700): Disabling LPT Port Support for VM. 2024-07-04 04:15:18 (1700): Disabling Audio Support for VM. 2024-07-04 04:15:18 (1700): Disabling Clipboard Support for VM. 2024-07-04 04:15:19 (1700): Disabling Drag and Drop Support for VM. 2024-07-04 04:15:19 (1700): Adding storage controller(s) to VM. 2024-07-04 04:15:19 (1700): Adding virtual disk drive to VM. (Theory_2024_04_30_prod.vdi) 2024-07-04 04:15:20 (1700): Attempts: 2 2024-07-04 04:15:21 (1700): Adding VirtualBox Guest Additions to VM. 2024-07-04 04:15:21 (1700): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2024-07-04 04:15:22 (1700): forwarding host port 55455 to guest port 80 2024-07-04 04:15:22 (1700): Enabling remote desktop for VM. 2024-07-04 04:15:22 (1700): Required extension pack not installed, remote desktop not enabled. 2024-07-04 04:15:22 (1700): Enabling shared directory for VM. 2024-07-04 04:15:23 (1700): Starting VM using VBoxManage interface. (boinc_1288bd1b5007bc86, slot#4) 2024-07-04 04:15:29 (1700): Error in start VM for VM: -2147467259 Command: VBoxManage -q startvm "boinc_1288bd1b5007bc86" --type headless Output: Waiting for VM "boinc_1288bd1b5007bc86" to power on... VBoxManage.exe: error: The native API dll was not found (C:\Windows\system32\WinHvPlatform.dll) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole 2024-07-04 04:15:29 (1700): VM failed to start. 2024-07-04 04:15:29 (1700): Could not start 2024-07-04 04:15:29 (1700): ERROR: VM failed to start 2024-07-04 04:15:29 (1700): Powering off VM. 2024-07-04 04:15:29 (1700): Deregistering VM. (boinc_1288bd1b5007bc86, slot#4) 2024-07-04 04:15:29 (1700): Removing network bandwidth throttle group from VM. 2024-07-04 04:15:29 (1700): Removing VM from VirtualBox. Hypervisor System Log: 00:00:06.779332 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:06.782402 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_ed036873ae61fb5d\boinc_ed036873ae61fb5d.vbox" with version "1.16-windows" 00:00:06.787710 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_ed036873ae61fb5d\boinc_ed036873ae61fb5d.vbox" with version "1.16-windows" 00:00:07.028778 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.031728 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.031939 Saving settings file "C:\Users\Notepad2\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:07.040896 Saving settings file "C:\Users\Notepad2\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:07.046118 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_ed036873ae61fb5d\boinc_ed036873ae61fb5d.vbox" with version "1.16-windows" 00:00:07.310151 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_ed036873ae61fb5d\boinc_ed036873ae61fb5d.vbox" with version "1.16-windows" 00:00:07.431771 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.432570 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.435293 Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_1288bd1b5007bc86\boinc_1288bd1b5007bc86.vbox" with version "1.16-windows" 00:00:07.466732 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_ed036873ae61fb5d\boinc_ed036873ae61fb5d.vbox" with version "1.16-windows" 00:00:07.472916 Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_1288bd1b5007bc86\boinc_1288bd1b5007bc86.vbox" with version "1.16-windows" 00:00:07.584957 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_ed036873ae61fb5d\boinc_ed036873ae61fb5d.vbox" with version "1.16-windows" 00:00:07.714417 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.715098 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.715982 Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_1288bd1b5007bc86\boinc_1288bd1b5007bc86.vbox" with version "1.16-windows" 00:00:07.993257 Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_1288bd1b5007bc86\boinc_1288bd1b5007bc86.vbox" with version "1.16-windows" 00:00:08.145486 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_ed036873ae61fb5d\boinc_ed036873ae61fb5d.vbox" with version "1.16-windows" 00:00:08.277529 Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_1288bd1b5007bc86\boinc_1288bd1b5007bc86.vbox" with version "1.16-windows" 00:00:08.432130 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.432334 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.444654 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:08.713101 Launched VM: 65000880 pid: 6716 (0x1a3c) frontend: headless name: boinc_ed036873ae61fb5d 00:00:08.864521 Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_1288bd1b5007bc86\boinc_1288bd1b5007bc86.vbox" with version "1.16-windows" 00:00:09.134821 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.134996 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.146242 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:09.410794 Launched VM: 65272992 pid: 6004 (0x1774) frontend: headless name: boinc_1288bd1b5007bc86 00:00:14.866278 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_ed036873ae61fb5d\boinc_ed036873ae61fb5d.vbox" with version "1.16-windows" 00:00:15.027340 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:15.242813 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_ed036873ae61fb5d\boinc_ed036873ae61fb5d.vbox" with version "1.16-windows" 00:00:15.529222 Saving settings file "C:\Users\Notepad2\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:15.543918 Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_1288bd1b5007bc86\boinc_1288bd1b5007bc86.vbox" with version "1.16-windows" 00:00:15.549940 DeleteVM Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_1288bd1b5007bc86\boinc_1288bd1b5007bc86.vbox" with version "1.16-windows" 00:00:15.556163 Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_1288bd1b5007bc86\boinc_1288bd1b5007bc86.vbox" with version "1.16-windows" 00:00:15.695445 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:15.860519 Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_1288bd1b5007bc86\boinc_1288bd1b5007bc86.vbox" with version "1.16-windows" 00:00:16.134751 Saving settings file "C:\Users\Notepad2\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:21.153665 main VirtualBox: object deletion starts 00:00:21.155180 main HostDnsMonitor: shutting down ... 00:00:21.155243 main HostDnsMonitor: shut down 00:00:21.156605 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:21.156885 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: ollers: 8 Maximum SAS Port count: 255 Maximum Devices per SAS Port: 1 Maximum NVMe PIIX3 Controllers: 1 Maximum NVMe ICH9 Controllers: 8 Maximum NVMe Port count: 255 Maximum Devices per NVMe Port: 1 Maximum virtio-scsi PIIX3 Controllers: 1 Maximum virtio-scsi ICH9 Controllers: 8 Maximum virtio-scsi Port count: 256 Maximum Devices per virtio-scsi Port: 1 Maximum PIIX3 Floppy Controllers:1 Maximum ICH9 Floppy Controllers: 1 Maximum Floppy Port count: 1 Maximum Devices per Floppy Port: 2 Default machine folder: C:\Users\Notepad2\VirtualBox VMs Raw-mode Supported: no Exclusive HW virtualization use: off Default hard disk format: VDI VRDE auth library: VBoxAuth Webservice auth. library: VBoxAuth Remote desktop ExtPack: Log history count: 3 Default frontend: Default audio driver: DirectSound Autostart database path: Default Guest Additions ISO: C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso Logging Level: all Proxy Mode: System Proxy URL: 2024-07-04 04:15:14 (1700): Command: VBoxManage -q list hostinfo Exit Code: 0 Output: Host Information: Host time: 2024-07-04T03:15:14.744000000Z Processor online count: 4 Processor count: 4 Processor online core count: 2 Processor core count: 2 Processor supports HW virtualization: no Processor supports PAE: yes Processor supports long mode: yes Processor supports nested paging: no Processor supports unrestricted guest: no Processor supports nested HW virtualization: no Processor#0 speed: unknown Processor#0 description: Intel(R) Core(TM) i7-7500U CPU @ 2.70GHz Processor#1 speed: unknown Processor#1 description: Intel(R) Core(TM) i7-7500U CPU @ 2.70GHz Processor#2 speed: unknown Processor#2 description: Intel(R) Core(TM) i7-7500U CPU @ 2.70GHz Processor#3 speed: unknown Processor#3 description: Intel(R) Core(TM) i7-7500U CPU @ 2.70GHz Memory size: 16263 MByte Memory available: 12162 MByte Operating system: Windows 10 Operating system version: 10.0.14393 2024-07-04 04:15:15 (1700): Command: VBoxManage -q showvminfo "boinc_1288bd1b5007bc86" --machinereadable Exit Code: -2135228415 Output: VBoxManage.exe: error: Could not find a registered machine named 'boinc_1288bd1b5007bc86' VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2715 of file VBoxManageInfo.cpp 2024-07-04 04:15:15 (1700): Command: VBoxManage -q createvm --name "boinc_1288bd1b5007bc86" --basefolder "C:\ProgramData\BOINC\slots\4" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_1288bd1b5007bc86' is created and registered. UUID: 86999799-9ebb-4523-9c1d-52e3a10dd828 Settings file: 'C:\ProgramData\BOINC\slots\4\boinc_1288bd1b5007bc86\boinc_1288bd1b5007bc86.vbox' 2024-07-04 04:15:15 (1700): Command: VBoxManage -q modifyvm "boinc_1288bd1b5007bc86" --description "Theory_2743-2730296-291_1" Exit Code: 0 Output: 2024-07-04 04:15:16 (1700): Command: VBoxManage -q modifyvm "boinc_1288bd1b5007bc86" --memory 630 Exit Code: 0 Output: 2024-07-04 04:15:16 (1700): Command: VBoxManage -q modifyvm "boinc_1288bd1b5007bc86" --cpus 1 Exit Code: 0 Output: 2024-07-04 04:15:16 (1700): Command: VBoxManage -q modifyvm "boinc_1288bd1b5007bc86" --acpi on --ioapic on --rtcuseutc off Exit Code: 0 Output: 2024-07-04 04:15:17 (1700): Command: VBoxManage -q modifyvm "boinc_1288bd1b5007bc86" --vram 16 --graphicscontroller VBoxVGA Exit Code: 0 Output: 2024-07-04 04:15:17 (1700): Command: VBoxManage -q modifyvm "boinc_1288bd1b5007bc86" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2024-07-04 04:15:17 (1700): Command: VBoxManage -q modifyvm "boinc_1288bd1b5007bc86" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2024-07-04 04:15:17 (1700): Command: VBoxManage -q modifyvm "boinc_1288bd1b5007bc86" --cableconnected1 on Exit Code: 0 Output: 2024-07-04 04:15:18 (1700): Command: VBoxManage -q modifyvm "boinc_1288bd1b5007bc86" --usb off Exit Code: 0 Output: 2024-07-04 04:15:18 (1700): Command: VBoxManage -q modifyvm "boinc_1288bd1b5007bc86" --uart1 off --uart2 off Exit Code: 0 Output: 2024-07-04 04:15:18 (1700): Command: VBoxManage -q modifyvm "boinc_1288bd1b5007bc86" --lpt1 off --lpt2 off Exit Code: 0 Output: 2024-07-04 04:15:18 (1700): Command: VBoxManage -q modifyvm "boinc_1288bd1b5007bc86" --audio none Exit Code: 0 Output: 2024-07-04 04:15:19 (1700): Command: VBoxManage -q modifyvm "boinc_1288bd1b5007bc86" --clipboard disabled Exit Code: 0 Output: 2024-07-04 04:15:19 (1700): Command: VBoxManage -q modifyvm "boinc_1288bd1b5007bc86" --draganddrop disabled Exit Code: 0 Output: 2024-07-04 04:15:19 (1700): Command: VBoxManage -q storagectl "boinc_1288bd1b5007bc86" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2024-07-04 04:15:21 (1700): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2024_04_30_prod.vdi" Exit Code: 0 Output: UUID: 3bbae7b0-9837-4992-8ac4-5c7feef1de80 Parent UUID: base State: created Type: multiattach Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\Theory_2024_04_30_prod.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 781 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 Child UUIDs: 3c3ee790-3e0d-48f7-867d-3fc56b3e8a49 2024-07-04 04:15:21 (1700): Command: VBoxManage -q storageattach "boinc_1288bd1b5007bc86" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2024_04_30_prod.vdi" Exit Code: 0 Output: 2024-07-04 04:15:21 (1700): Command: VBoxManage -q storageattach "boinc_1288bd1b5007bc86" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2024-07-04 04:15:22 (1700): Command: VBoxManage -q bandwidthctl "boinc_1288bd1b5007bc86" add "boinc_1288bd1b5007bc86_net" --type network --limit 1024G Exit Code: 0 Output: 2024-07-04 04:15:22 (1700): Command: VBoxManage -q modifyvm "boinc_1288bd1b5007bc86" --natpf1 ",tcp,127.0.0.1,55455,,80" Exit Code: 0 Output: 2024-07-04 04:15:22 (1700): Command: VBoxManage -q list extpacks Exit Code: 0 Output: Extension Packs: 0 2024-07-04 04:15:22 (1700): Command: VBoxManage -q sharedfolder add "boinc_1288bd1b5007bc86" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\4/shared" Exit Code: 0 Output: 2024-07-04 04:15:29 (1700): Command: VBoxManage -q startvm "boinc_1288bd1b5007bc86" --type headless Exit Code: -2147467259 Output: Waiting for VM "boinc_1288bd1b5007bc86" to power on... VBoxManage.exe: error: The native API dll was not found (C:\Windows\system32\WinHvPlatform.dll) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole 2024-07-04 04:15:29 (1700): Command: VBoxManage -q snapshot "boinc_1288bd1b5007bc86" list Exit Code: -108 Output: This machine does not have any snapshots 2024-07-04 04:15:29 (1700): Command: VBoxManage -q bandwidthctl "boinc_1288bd1b5007bc86" remove "boinc_1288bd1b5007bc86_net" Exit Code: 0 Output: 2024-07-04 04:15:30 (1700): Command: VBoxManage -q unregistervm "boinc_1288bd1b5007bc86" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 2024-07-04 04:15:35 (1700): called boinc_finish(-2147467259) </stderr_txt> ]]>
©2024 CERN