Name Theory_2773-2942247-108_1
Workunit 223694265
Created 23 Jun 2024, 2:12:25 UTC
Sent 23 Jun 2024, 16:12:09 UTC
Report deadline 4 Jul 2024, 16:12:09 UTC
Received 23 Jun 2024, 16:14:53 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status 5 (0x00000005) Unknown error code
Computer ID 10851878
Run time 9 sec
CPU time 0 sec
Validate state Invalid
Credit 0.00
Device peak FLOPS 1.00 GFLOPS
Application version Theory Simulation v300.50 (vbox64_theory)
x86_64-apple-darwin
Peak working set size 1.65 MB
Peak swap size 32.60 GB
Peak disk usage 1.33 MB

Stderr output

<core_client_version>7.24.3</core_client_version>
<![CDATA[
<message>
process exited with code 5 (0x5, -251)</message>
<stderr_txt>
2024-06-23 17:12:13 (9459): vboxwrapper version 26207
2024-06-23 17:12:13 (9459): BOINC client version: 7.24.3
2024-06-23 17:12:14 (9459): Detected: VirtualBox VboxManage Interface (Version: 7.0.6)
2024-06-23 17:12:14 (9459): Detected: Sandbox Configuration Enabled
2024-06-23 17:12:14 (9459): Detected: Heartbeat check (file: 'heartbeat' every 1200.000000 seconds)
2024-06-23 17:12:14 (9459): Successfully copied 'init_data.xml' to the shared directory.
2024-06-23 17:12:14 (9459): Successfully copied 'input' to the shared directory.
2024-06-23 17:12:14 (9459): Create VM. (boinc_df097f61f55a7997, slot#1)
2024-06-23 17:12:14 (9459): Setting Memory Size for VM. (630MB)
2024-06-23 17:12:14 (9459): Setting CPU Count for VM. (1)
2024-06-23 17:12:14 (9459): Setting Chipset Options for VM.
2024-06-23 17:12:14 (9459): Setting Graphics Controller Options for VM.
2024-06-23 17:12:14 (9459): Setting Boot Options for VM.
2024-06-23 17:12:14 (9459): Setting Network Configuration for NAT.
2024-06-23 17:12:15 (9459): Enabling VM Network Access.
2024-06-23 17:12:15 (9459): Disabling USB Support for VM.
2024-06-23 17:12:15 (9459): Disabling COM Port Support for VM.
2024-06-23 17:12:15 (9459): Disabling Audio Support for VM.
2024-06-23 17:12:15 (9459): Disabling Clipboard Support for VM.
2024-06-23 17:12:15 (9459): Disabling Drag and Drop Support for VM.
2024-06-23 17:12:15 (9459): Adding storage controller(s) to VM.
2024-06-23 17:12:15 (9459): Adding virtual disk drive to VM. (Theory_2024_05_03_prod.vdi)
2024-06-23 17:12:16 (9459): Adding VirtualBox Guest Additions to VM.
2024-06-23 17:12:16 (9459): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2024-06-23 17:12:16 (9459): forwarding host port 56542 to guest port 80
2024-06-23 17:12:16 (9459): Enabling remote desktop for VM.
2024-06-23 17:12:16 (9459): Required extension pack not installed, remote desktop not enabled.
2024-06-23 17:12:16 (9459): Enabling shared directory for VM.
2024-06-23 17:12:16 (9459): Starting VM using VBoxManage interface. (boinc_df097f61f55a7997, slot#1)
2024-06-23 17:12:16 (9459): Error in start VM for VM: -2147467259
Command:
VBoxManage -q startvm "boinc_df097f61f55a7997" --type headless
Output:
VBoxManage: error: The virtual machine 'boinc_df097f61f55a7997' has terminated unexpectedly during startup because of signal 9
VBoxManage: error: Details: code NS_ERROR_FAILURE (0x80004005), component MachineWrap, interface IMachine
Waiting for VM "boinc_df097f61f55a7997" to power on...

2024-06-23 17:12:16 (9459): VM failed to start.
2024-06-23 17:12:16 (9459): Could not start 
2024-06-23 17:12:16 (9459): ERROR: VM failed to start
2024-06-23 17:12:16 (9459): Powering off VM.
2024-06-23 17:12:16 (9459): Deregistering VM. (boinc_df097f61f55a7997, slot#1)
2024-06-23 17:12:16 (9459): Removing network bandwidth throttle group from VM.
2024-06-23 17:12:16 (9459): Removing VM from VirtualBox.

    Hypervisor System Log:

00:00:00.013199 main     VirtualBox XPCOM Server 7.0.6 r155176 darwin.amd64 (Jan 11 2023 17:40:04) release log
00:00:00.013202 main     Log opened 2024-06-23T16:12:14.118632000Z
00:00:00.013202 main     Build Type: release
00:00:00.013217 main     OS Product: Darwin
00:00:00.013224 main     OS Release: 23.4.0
00:00:00.013230 main     OS Version: Darwin Kernel Version 23.4.0: Fri Mar 15 00:11:05 PDT 2024; root:xnu-10063.101.17~1/RELEASE_X86_64
00:00:00.013348 main     DMI Product Name: MacBookPro15,2
00:00:00.013392 main     DMI Product Version: 1.0
00:00:00.013396 main     Firmware type: failed - VERR_NOT_SUPPORTED
00:00:00.013419 main     Host RAM: 8192MB (8.0GB) total, 2180MB (2.1GB) available
00:00:00.013423 main     Executable: /Applications/VirtualBox.app/Contents/MacOS/VBoxSVC
00:00:00.013424 main     Process ID: 9474
00:00:00.013424 main     Package type: DARWIN_64BITS_GENERIC
00:00:00.016662 main     IPC socket path: /tmp/.vbox-boinc_project-ipc/ipcd

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

VBoxManage: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 3139 of file VBoxManageInfo.cpp

2024-06-23 17:12:14 (9459): 
Command: VBoxManage -q createvm --name "boinc_df097f61f55a7997" --basefolder "/Library/Application Support/BOINC Data/slots/1" --ostype "Linux26_64" --register
Exit Code: 0
Output:
Virtual machine 'boinc_df097f61f55a7997' is created and registered.
UUID: 27d21546-5e26-4a32-a387-4cf05ed7f015
Settings file: '/Library/Application Support/BOINC Data/slots/1/boinc_df097f61f55a7997/boinc_df097f61f55a7997.vbox'

2024-06-23 17:12:14 (9459): 
Command: VBoxManage -q modifyvm "boinc_df097f61f55a7997" --description "Theory_2773-2942247-108_1" 
Exit Code: 0
Output:

2024-06-23 17:12:14 (9459): 
Command: VBoxManage -q modifyvm "boinc_df097f61f55a7997" --memory 630 
Exit Code: 0
Output:

2024-06-23 17:12:14 (9459): 
Command: VBoxManage -q modifyvm "boinc_df097f61f55a7997" --cpus 1 
Exit Code: 0
Output:

2024-06-23 17:12:14 (9459): 
Command: VBoxManage -q modifyvm "boinc_df097f61f55a7997" --acpi on --ioapic on --rtcuseutc on 
Exit Code: 0
Output:

2024-06-23 17:12:14 (9459): 
Command: VBoxManage -q modifyvm "boinc_df097f61f55a7997" --vram 16 --graphicscontroller VBoxVGA 
Exit Code: 0
Output:

2024-06-23 17:12:14 (9459): 
Command: VBoxManage -q modifyvm "boinc_df097f61f55a7997" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2024-06-23 17:12:15 (9459): 
Command: VBoxManage -q modifyvm "boinc_df097f61f55a7997" --nic1 nat --natdnsproxy1 on --cableconnected1 off 
Exit Code: 0
Output:

2024-06-23 17:12:15 (9459): 
Command: VBoxManage -q modifyvm "boinc_df097f61f55a7997" --cableconnected1 on 
Exit Code: 0
Output:

2024-06-23 17:12:15 (9459): 
Command: VBoxManage -q modifyvm "boinc_df097f61f55a7997" --usb off 
Exit Code: 0
Output:

2024-06-23 17:12:15 (9459): 
Command: VBoxManage -q modifyvm "boinc_df097f61f55a7997" --uart1 off --uart2 off 
Exit Code: 0
Output:

2024-06-23 17:12:15 (9459): 
Command: VBoxManage -q modifyvm "boinc_df097f61f55a7997" --audio-enabled off 
Exit Code: 0
Output:

2024-06-23 17:12:15 (9459): 
Command: VBoxManage -q modifyvm "boinc_df097f61f55a7997" --clipboard disabled 
Exit Code: 0
Output:

2024-06-23 17:12:15 (9459): 
Command: VBoxManage -q modifyvm "boinc_df097f61f55a7997" --draganddrop disabled 
Exit Code: 0
Output:

2024-06-23 17:12:15 (9459): 
Command: VBoxManage -q storagectl "boinc_df097f61f55a7997" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2024-06-23 17:12:15 (9459): 
Command: VBoxManage -q showhdinfo "/Library/Application Support/BOINC Data/projects/lhcathome.cern.ch_lhcathome/Theory_2024_05_03_prod.vdi" 
Exit Code: 0
Output:
UUID:           088a56fe-9ca1-4a9e-ac6f-55fc3c5a4cc4
Parent UUID:    base
State:          created
Type:           multiattach
Location:       /Library/Application Support/BOINC Data/projects/lhcathome.cern.ch_lhcathome/Theory_2024_05_03_prod.vdi
Storage format: VDI
Format variant: dynamic default
Capacity:       20480 MBytes
Size on disk:   781 MBytes
Encryption:     disabled
Property:       AllocationBlockSize=1048576

2024-06-23 17:12:15 (9459): 
Command: VBoxManage -q storageattach "boinc_df097f61f55a7997" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "/Library/Application Support/BOINC Data/projects/lhcathome.cern.ch_lhcathome/Theory_2024_05_03_prod.vdi" 
Exit Code: -2135228409
Output:
VBoxManage: error: Cannot attach medium '/Library/Application Support/BOINC Data/projects/lhcathome.cern.ch_lhcathome/Theory_2024_05_03_prod.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later
VBoxManage: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee nsISupports
VBoxManage: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 785 of file VBoxManageStorageController.cpp

2024-06-23 17:12:15 (9459): 
Command: VBoxManage -q showhdinfo "/Library/Application Support/BOINC Data/projects/lhcathome.cern.ch_lhcathome/Theory_2024_05_03_prod.vdi" 
Exit Code: 0
Output:
UUID:           088a56fe-9ca1-4a9e-ac6f-55fc3c5a4cc4
Parent UUID:    base
State:          created
Type:           multiattach
Location:       /Library/Application Support/BOINC Data/projects/lhcathome.cern.ch_lhcathome/Theory_2024_05_03_prod.vdi
Storage format: VDI
Format variant: dynamic default
Capacity:       20480 MBytes
Size on disk:   781 MBytes
Encryption:     disabled
Property:       AllocationBlockSize=1048576

2024-06-23 17:12:15 (9459): 
Command: VBoxManage -q closemedium disk "/Library/Application Support/BOINC Data/projects/lhcathome.cern.ch_lhcathome/Theory_2024_05_03_prod.vdi" 
Exit Code: 0
Output:

2024-06-23 17:12:15 (9459): 
Command: VBoxManage -q showhdinfo "/Library/Application Support/BOINC Data/projects/lhcathome.cern.ch_lhcathome/Theory_2024_05_03_prod.vdi" 
Exit Code: 0
Output:
UUID:           088a56fe-9ca1-4a9e-ac6f-55fc3c5a4cc4
Parent UUID:    base
State:          created
Type:           normal (base)
Location:       /Library/Application Support/BOINC Data/projects/lhcathome.cern.ch_lhcathome/Theory_2024_05_03_prod.vdi
Storage format: VDI
Format variant: dynamic default
Capacity:       20480 MBytes
Size on disk:   781 MBytes
Encryption:     disabled
Property:       AllocationBlockSize=1048576

2024-06-23 17:12:15 (9459): 
Command: VBoxManage -q storageattach "boinc_df097f61f55a7997" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "/Library/Application Support/BOINC Data/projects/lhcathome.cern.ch_lhcathome/Theory_2024_05_03_prod.vdi" 
Exit Code: 0
Output:

2024-06-23 17:12:15 (9459): 
Command: VBoxManage -q storageattach "boinc_df097f61f55a7997" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none 
Exit Code: 0
Output:

2024-06-23 17:12:16 (9459): 
Command: VBoxManage -q storageattach "boinc_df097f61f55a7997" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "/Library/Application Support/BOINC Data/projects/lhcathome.cern.ch_lhcathome/Theory_2024_05_03_prod.vdi" 
Exit Code: 0
Output:

2024-06-23 17:12:16 (9459): 
Command: VBoxManage -q storageattach "boinc_df097f61f55a7997" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "/Applications/VirtualBox.app/Contents/MacOS/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2024-06-23 17:12:16 (9459): 
Command: VBoxManage -q bandwidthctl "boinc_df097f61f55a7997" add "boinc_df097f61f55a7997_net" --type network --limit 1024G 
Exit Code: 0
Output:

2024-06-23 17:12:16 (9459): 
Command: VBoxManage -q modifyvm "boinc_df097f61f55a7997" --natpf1 ",tcp,127.0.0.1,56542,,80" 
Exit Code: 0
Output:

2024-06-23 17:12:16 (9459): 
Command: VBoxManage -q list extpacks
Exit Code: 0
Output:
Extension Packs: 0

2024-06-23 17:12:16 (9459): 
Command: VBoxManage -q sharedfolder add "boinc_df097f61f55a7997" --name "shared" --hostpath "/Library/Application Support/BOINC Data/slots/1/shared"
Exit Code: 0
Output:

2024-06-23 17:12:16 (9459): 
Command: VBoxManage -q startvm "boinc_df097f61f55a7997" --type headless
Exit Code: -2147467259
Output:
VBoxManage: error: The virtual machine 'boinc_df097f61f55a7997' has terminated unexpectedly during startup because of signal 9
VBoxManage: error: Details: code NS_ERROR_FAILURE (0x80004005), component MachineWrap, interface IMachine
Waiting for VM "boinc_df097f61f55a7997" to power on...

2024-06-23 17:12:16 (9459): 
Command: VBoxManage -q snapshot "boinc_df097f61f55a7997" list 
Exit Code: 0
Output:
This machine does not have any snapshots

2024-06-23 17:12:16 (9459): 
Command: VBoxManage -q bandwidthctl "boinc_df097f61f55a7997" remove "boinc_df097f61f55a7997_net" 
Exit Code: 0
Output:

2024-06-23 17:12:16 (9459): 
Command: VBoxManage -q unregistervm "boinc_df097f61f55a7997" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

2024-06-23 17:12:21 (9459): called boinc_finish(-2147467259)

</stderr_txt>
]]>


©2024 CERN