Name | Theory_2773-2929208-54_0 |
Workunit | 223598737 |
Created | 13 Jun 2024, 11:21:42 UTC |
Sent | 14 Jun 2024, 17:09:06 UTC |
Report deadline | 25 Jun 2024, 17:09:06 UTC |
Received | 14 Jun 2024, 17:56:25 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | -2147467259 (0x80004005) Unknown error code |
Computer ID | 10833196 |
Run time | 24 sec |
CPU time | 0 sec |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 5.37 GFLOPS |
Application version | Theory Simulation v300.30 (vbox64_theory) windows_x86_64 |
Peak working set size | 11.16 MB |
Peak swap size | 6.23 MB |
Peak disk usage | 2.17 MB |
<core_client_version>7.24.1</core_client_version> <![CDATA[ <message> Error no especificado (0x80004005) - exit code 2147500037 (0x80004005)</message> <stderr_txt> 2024-06-14 19:09:35 (19160): vboxwrapper version 26207 2024-06-14 19:09:35 (19160): BOINC client version: 7.24.1 2024-06-14 19:09:36 (19160): Detected: VirtualBox VboxManage Interface (Version: 7.0.8) 2024-06-14 19:09:36 (19160): Detected: Heartbeat check (file: 'heartbeat' every 1200.000000 seconds) 2024-06-14 19:09:36 (19160): Successfully copied 'init_data.xml' to the shared directory. 2024-06-14 19:09:36 (19160): Successfully copied 'input' to the shared directory. 2024-06-14 19:09:36 (19160): Create VM. (boinc_dcf0d23b82a206a0, slot#34) 2024-06-14 19:09:37 (19160): Setting Memory Size for VM. (630MB) 2024-06-14 19:09:37 (19160): Setting CPU Count for VM. (1) 2024-06-14 19:09:38 (19160): Setting Chipset Options for VM. 2024-06-14 19:09:38 (19160): Setting Graphics Controller Options for VM. 2024-06-14 19:09:38 (19160): Setting Boot Options for VM. 2024-06-14 19:09:38 (19160): Setting Network Configuration for NAT. 2024-06-14 19:09:39 (19160): Enabling VM Network Access. 2024-06-14 19:09:39 (19160): Disabling USB Support for VM. 2024-06-14 19:09:39 (19160): Disabling COM Port Support for VM. 2024-06-14 19:09:39 (19160): Disabling LPT Port Support for VM. 2024-06-14 19:09:40 (19160): Disabling Audio Support for VM. 2024-06-14 19:09:40 (19160): Disabling Clipboard Support for VM. 2024-06-14 19:09:40 (19160): Disabling Drag and Drop Support for VM. 2024-06-14 19:09:41 (19160): Adding storage controller(s) to VM. 2024-06-14 19:09:42 (19160): Adding virtual disk drive to VM. (Theory_2024_04_30_prod.vdi) 2024-06-14 19:09:44 (19160): Adding VirtualBox Guest Additions to VM. 2024-06-14 19:09:45 (19160): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2024-06-14 19:09:45 (19160): forwarding host port 54503 to guest port 80 2024-06-14 19:09:45 (19160): Enabling remote desktop for VM. 2024-06-14 19:09:45 (19160): Required extension pack not installed, remote desktop not enabled. 2024-06-14 19:09:45 (19160): Enabling shared directory for VM. 2024-06-14 19:09:46 (19160): Starting VM using VBoxManage interface. (boinc_dcf0d23b82a206a0, slot#34) 2024-06-14 19:09:49 (19160): Error in start VM for VM: -2147467259 Command: VBoxManage -q startvm "boinc_dcf0d23b82a206a0" --type headless Output: VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: AMD-V is disabled in the BIOS (or by the host OS) (VERR_SVM_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole Waiting for VM "boinc_dcf0d23b82a206a0" to power on... 2024-06-14 19:09:49 (19160): VM failed to start. 2024-06-14 19:09:49 (19160): Could not start 2024-06-14 19:09:49 (19160): ERROR: VM failed to start 2024-06-14 19:09:49 (19160): Powering off VM. 2024-06-14 19:09:49 (19160): Deregistering VM. (boinc_dcf0d23b82a206a0, slot#34) 2024-06-14 19:09:49 (19160): Removing network bandwidth throttle group from VM. 2024-06-14 19:09:50 (19160): Removing VM from VirtualBox. Hypervisor System Log: 00:00:11.101233 Saving settings file "C:\ProgramData\BOINC\slots\33\boinc_ac5260bb254f0f6d\boinc_ac5260bb254f0f6d.vbox" with version "1.19-windows" 00:00:11.106723 Finished saving settings file "C:\ProgramData\BOINC\slots\33\boinc_ac5260bb254f0f6d\boinc_ac5260bb254f0f6d.vbox" 00:00:11.396163 Saving settings file "C:\ProgramData\BOINC\slots\33\boinc_ac5260bb254f0f6d\boinc_ac5260bb254f0f6d.vbox" with version "1.19-windows" 00:00:11.403487 Finished saving settings file "C:\ProgramData\BOINC\slots\33\boinc_ac5260bb254f0f6d\boinc_ac5260bb254f0f6d.vbox" 00:00:11.526491 Saving settings file "C:\ProgramData\BOINC\slots\31\boinc_a205f456f596941b\boinc_a205f456f596941b.vbox" with version "1.19-windows" 00:00:11.535846 Finished saving settings file "C:\ProgramData\BOINC\slots\31\boinc_a205f456f596941b\boinc_a205f456f596941b.vbox" 00:00:11.677738 Saving settings file "C:\ProgramData\BOINC\slots\33\boinc_ac5260bb254f0f6d\boinc_ac5260bb254f0f6d.vbox" with version "1.19-windows" 00:00:11.684164 Finished saving settings file "C:\ProgramData\BOINC\slots\33\boinc_ac5260bb254f0f6d\boinc_ac5260bb254f0f6d.vbox" 00:00:11.793282 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={Ńo extension pack providing a cryptographic support module could be found}, preserve=false aResultDetail=0 00:00:11.797922 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:11.797982 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:11.803486 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:12.096656 Launched VM: 1061861104 pid: 4596 (0x11f4) frontend: headless name: boinc_a205f456f596941b 00:00:12.245261 Saving settings file "C:\ProgramData\BOINC\slots\33\boinc_ac5260bb254f0f6d\boinc_ac5260bb254f0f6d.vbox" with version "1.19-windows" 00:00:12.253346 Finished saving settings file "C:\ProgramData\BOINC\slots\33\boinc_ac5260bb254f0f6d\boinc_ac5260bb254f0f6d.vbox" 00:00:12.518598 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={Ńo extension pack providing a cryptographic support module could be found}, preserve=false aResultDetail=0 00:00:12.523647 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:12.523707 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:12.529472 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:12.827011 Launched VM: 1061845968 pid: 8524 (0x214c) frontend: headless name: boinc_ac5260bb254f0f6d 00:00:13.832053 Saving settings file "C:\ProgramData\BOINC\slots\34\boinc_dcf0d23b82a206a0\boinc_dcf0d23b82a206a0.vbox" with version "1.19-windows" 00:00:13.837862 Finished saving settings file "C:\ProgramData\BOINC\slots\34\boinc_dcf0d23b82a206a0\boinc_dcf0d23b82a206a0.vbox" 00:00:13.894886 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:14.217087 Saving settings file "C:\Users\NCLJ\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:14.224866 Finished saving settings file "C:\Users\NCLJ\.VirtualBox\VirtualBox.xml" 00:00:14.225071 Saving settings file "C:\ProgramData\BOINC\slots\31\boinc_a205f456f596941b\boinc_a205f456f596941b.vbox" with version "1.19-windows" 00:00:14.231170 Finished saving settings file "C:\ProgramData\BOINC\slots\31\boinc_a205f456f596941b\boinc_a205f456f596941b.vbox" 00:00:14.232130 DeleteVM Saving settings file "C:\ProgramData\BOINC\slots\31\boinc_a205f456f596941b\boinc_a205f456f596941b.vbox" with version "1.19-windows" 00:00:14.237668 DeleteVM Finished saving settings file "C:\ProgramData\BOINC\slots\31\boinc_a205f456f596941b\boinc_a205f456f596941b.vbox" 00:00:15.401816 Saving settings file "C:\ProgramData\BOINC\slots\31\boinc_a205f456f596941b\boinc_a205f456f596941b.vbox" with version "1.19-windows" 00:00:15.428960 Finished saving settings file "C:\ProgramData\BOINC\slots\31\boinc_a205f456f596941b\boinc_a205f456f596941b.vbox" 00:00:15.487701 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:15.807211 Saving settings file "C:\Users\NCLJ\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:15.858092 Finished saving settings file "C:\Users\NCLJ\.VirtualBox\VirtualBox.xml" 00:00:15.858289 Saving settings file "C:\ProgramData\BOINC\slots\33\boinc_ac5260bb254f0f6d\boinc_ac5260bb254f0f6d.vbox" with version "1.19-windows" 00:00:15.870763 Finished saving settings file "C:\ProgramData\BOINC\slots\33\boinc_ac5260bb254f0f6d\boinc_ac5260bb254f0f6d.vbox" 00:00:15.871552 DeleteVM Saving settings file "C:\ProgramData\BOINC\slots\33\boinc_ac5260bb254f0f6d\boinc_ac5260bb254f0f6d.vbox" with version "1.19-windows" 00:00:15.888253 DeleteVM Finished saving settings file "C:\ProgramData\BOINC\slots\33\boinc_ac5260bb254f0f6d\boinc_ac5260bb254f0f6d.vbox" 00:00:16.136471 Saving settings file "C:\ProgramData\BOINC\slots\33\boinc_ac5260bb254f0f6d\boinc_ac5260bb254f0f6d.vbox" with version "1.19-windows" 00:00:16.146989 Finished saving settings file "C:\ProgramData\BOINC\slots\33\boinc_ac5260bb254f0f6d\boinc_ac5260bb254f0f6d.vbox" 00:00:16.206316 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:16.527262 Saving settings file "C:\Users\NCLJ\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:16.540740 Finished saving settings file "C:\Users\NCLJ\.VirtualBox\VirtualBox.xml" 00:00:16.540877 Saving settings file "C:\Users\NCLJ\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:16.554151 Finished saving settings file "C:\Users\NCLJ\.VirtualBox\VirtualBox.xml" 00:00:16.554958 DeleteVM Saving settings file "C:\Users\NCLJ\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:16.567026 DeleteVM Finished saving settings file "C:\Users\NCLJ\.VirtualBox\VirtualBox.xml" 00:00:21.580901 main VirtualBox: object deletion starts 00:00:21.581513 main HostDnsMonitor: shutting down ... 00:00:21.581528 main HostDnsMonitor: shut down 00:00:21.582751 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:21.582937 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: (19160): Command: VBoxManage -q createvm --name "boinc_dcf0d23b82a206a0" --basefolder "C:\ProgramData\BOINC\slots\34" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_dcf0d23b82a206a0' is created and registered. UUID: 7e76376e-146d-4a98-8838-67434f2fd065 Settings file: 'C:\ProgramData\BOINC\slots\34\boinc_dcf0d23b82a206a0\boinc_dcf0d23b82a206a0.vbox' 2024-06-14 19:09:37 (19160): Command: VBoxManage -q modifyvm "boinc_dcf0d23b82a206a0" --description "Theory_2773-2929208-54_0" Exit Code: 0 Output: 2024-06-14 19:09:37 (19160): Command: VBoxManage -q modifyvm "boinc_dcf0d23b82a206a0" --memory 630 Exit Code: 0 Output: 2024-06-14 19:09:38 (19160): Command: VBoxManage -q modifyvm "boinc_dcf0d23b82a206a0" --cpus 1 Exit Code: 0 Output: 2024-06-14 19:09:38 (19160): Command: VBoxManage -q modifyvm "boinc_dcf0d23b82a206a0" --acpi on --ioapic on --rtcuseutc off Exit Code: 0 Output: 2024-06-14 19:09:38 (19160): Command: VBoxManage -q modifyvm "boinc_dcf0d23b82a206a0" --vram 16 --graphicscontroller VBoxVGA Exit Code: 0 Output: 2024-06-14 19:09:38 (19160): Command: VBoxManage -q modifyvm "boinc_dcf0d23b82a206a0" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2024-06-14 19:09:39 (19160): Command: VBoxManage -q modifyvm "boinc_dcf0d23b82a206a0" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2024-06-14 19:09:39 (19160): Command: VBoxManage -q modifyvm "boinc_dcf0d23b82a206a0" --cableconnected1 on Exit Code: 0 Output: 2024-06-14 19:09:39 (19160): Command: VBoxManage -q modifyvm "boinc_dcf0d23b82a206a0" --usb off Exit Code: 0 Output: 2024-06-14 19:09:39 (19160): Command: VBoxManage -q modifyvm "boinc_dcf0d23b82a206a0" --uart1 off --uart2 off Exit Code: 0 Output: 2024-06-14 19:09:40 (19160): Command: VBoxManage -q modifyvm "boinc_dcf0d23b82a206a0" --lpt1 off --lpt2 off Exit Code: 0 Output: 2024-06-14 19:09:40 (19160): Command: VBoxManage -q modifyvm "boinc_dcf0d23b82a206a0" --audio-enabled off Exit Code: 0 Output: 2024-06-14 19:09:40 (19160): Command: VBoxManage -q modifyvm "boinc_dcf0d23b82a206a0" --clipboard disabled Exit Code: 0 Output: 2024-06-14 19:09:41 (19160): Command: VBoxManage -q modifyvm "boinc_dcf0d23b82a206a0" --draganddrop disabled Exit Code: 0 Output: 2024-06-14 19:09:42 (19160): Command: VBoxManage -q storagectl "boinc_dcf0d23b82a206a0" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2024-06-14 19:09:42 (19160): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2024_04_30_prod.vdi" Exit Code: 0 Output: UUID: 3bbae7b0-9837-4992-8ac4-5c7feef1de80 Parent UUID: base State: created Type: multiattach Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\Theory_2024_04_30_prod.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 781 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2024-06-14 19:09:43 (19160): Command: VBoxManage -q storageattach "boinc_dcf0d23b82a206a0" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2024_04_30_prod.vdi" Exit Code: -2135228409 Output: VBoxManage.exe: error: Cannot attach medium 'C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\Theory_2024_04_30_prod.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 785 of file VBoxManageStorageController.cpp 2024-06-14 19:09:43 (19160): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2024_04_30_prod.vdi" Exit Code: 0 Output: UUID: 3bbae7b0-9837-4992-8ac4-5c7feef1de80 Parent UUID: base State: created Type: multiattach Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\Theory_2024_04_30_prod.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 781 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2024-06-14 19:09:43 (19160): Command: VBoxManage -q closemedium disk "C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\Theory_2024_04_30_prod.vdi" Exit Code: 0 Output: 2024-06-14 19:09:44 (19160): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2024_04_30_prod.vdi" Exit Code: 0 Output: UUID: 3bbae7b0-9837-4992-8ac4-5c7feef1de80 Parent UUID: base State: created Type: normal (base) Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\Theory_2024_04_30_prod.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 781 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2024-06-14 19:09:44 (19160): Command: VBoxManage -q storageattach "boinc_dcf0d23b82a206a0" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2024_04_30_prod.vdi" Exit Code: 0 Output: 2024-06-14 19:09:44 (19160): Command: VBoxManage -q storageattach "boinc_dcf0d23b82a206a0" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none Exit Code: 0 Output: 2024-06-14 19:09:44 (19160): Command: VBoxManage -q storageattach "boinc_dcf0d23b82a206a0" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/Theory_2024_04_30_prod.vdi" Exit Code: 0 Output: 2024-06-14 19:09:45 (19160): Command: VBoxManage -q storageattach "boinc_dcf0d23b82a206a0" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2024-06-14 19:09:45 (19160): Command: VBoxManage -q bandwidthctl "boinc_dcf0d23b82a206a0" add "boinc_dcf0d23b82a206a0_net" --type network --limit 1024G Exit Code: 0 Output: 2024-06-14 19:09:45 (19160): Command: VBoxManage -q modifyvm "boinc_dcf0d23b82a206a0" --natpf1 ",tcp,127.0.0.1,54503,,80" Exit Code: 0 Output: 2024-06-14 19:09:45 (19160): Command: VBoxManage -q list extpacks Exit Code: 0 Output: Extension Packs: 0 2024-06-14 19:09:46 (19160): Command: VBoxManage -q sharedfolder add "boinc_dcf0d23b82a206a0" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\34/shared" Exit Code: 0 Output: 2024-06-14 19:09:49 (19160): Command: VBoxManage -q startvm "boinc_dcf0d23b82a206a0" --type headless Exit Code: -2147467259 Output: VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: AMD-V is disabled in the BIOS (or by the host OS) (VERR_SVM_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole Waiting for VM "boinc_dcf0d23b82a206a0" to power on... 2024-06-14 19:09:49 (19160): Command: VBoxManage -q snapshot "boinc_dcf0d23b82a206a0" list Exit Code: -108 Output: This machine does not have any snapshots 2024-06-14 19:09:50 (19160): Command: VBoxManage -q bandwidthctl "boinc_dcf0d23b82a206a0" remove "boinc_dcf0d23b82a206a0_net" Exit Code: 0 Output: VBoxManage.exe: error: Bandwidth groups cannot be deleted while the VM is running 2024-06-14 19:09:50 (19160): Command: VBoxManage -q unregistervm "boinc_dcf0d23b82a206a0" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 2024-06-14 19:09:58 (19160): called boinc_finish(-2147467259) </stderr_txt> ]]>
©2024 CERN