Name | CMS_3185046_1716086858.920452_0 |
Workunit | 223106066 |
Created | 19 May 2024, 2:47:42 UTC |
Sent | 19 May 2024, 3:17:19 UTC |
Report deadline | 19 Jun 2024, 3:17:19 UTC |
Received | 19 May 2024, 3:20:31 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | -2147467259 (0x80004005) Unknown error code |
Computer ID | 10680734 |
Run time | 4 sec |
CPU time | 0 sec |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 12.37 GFLOPS |
Application version | CMS Simulation v70.30 (vbox64_mt_mcore_cms) windows_x86_64 |
Peak working set size | 11.65 MB |
Peak swap size | 6.23 MB |
Peak disk usage | 11.20 KB |
<core_client_version>7.24.1</core_client_version> <![CDATA[ <message> Unspecified error (0x80004005) - exit code 2147500037 (0x80004005)</message> <stderr_txt> 2024-05-18 20:16:56 (60588): vboxwrapper version 26207 2024-05-18 20:16:56 (60588): BOINC client version: 7.24.1 2024-05-18 20:16:58 (60588): Detected: VirtualBox VboxManage Interface (Version: 6.1.12) 2024-05-18 20:16:59 (60588): Detected: Heartbeat check (file: 'heartbeat' every 1200.000000 seconds) 2024-05-18 20:16:59 (60588): Successfully copied 'init_data.xml' to the shared directory. 2024-05-18 20:16:59 (60588): Create VM. (boinc_55f75617201975d3, slot#8) 2024-05-18 20:16:59 (60588): Setting Memory Size for VM. (4584MB) 2024-05-18 20:17:00 (60588): Setting CPU Count for VM. (4) 2024-05-18 20:17:00 (60588): Setting Chipset Options for VM. 2024-05-18 20:17:00 (60588): Setting Graphics Controller Options for VM. 2024-05-18 20:17:01 (60588): Setting Boot Options for VM. 2024-05-18 20:17:01 (60588): Setting Network Configuration for NAT. 2024-05-18 20:17:01 (60588): Enabling VM Network Access. 2024-05-18 20:17:01 (60588): Disabling USB Support for VM. 2024-05-18 20:17:02 (60588): Disabling COM Port Support for VM. 2024-05-18 20:17:02 (60588): Disabling LPT Port Support for VM. 2024-05-18 20:17:02 (60588): Disabling Audio Support for VM. 2024-05-18 20:17:03 (60588): Disabling Clipboard Support for VM. 2024-05-18 20:17:03 (60588): Disabling Drag and Drop Support for VM. 2024-05-18 20:17:03 (60588): Adding storage controller(s) to VM. 2024-05-18 20:17:03 (60588): Adding virtual disk drive to VM. (CMS_2024_04_29_prod.vdi) 2024-05-18 20:17:04 (60588): Adding VirtualBox Guest Additions to VM. 2024-05-18 20:17:05 (60588): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2024-05-18 20:17:05 (60588): forwarding host port 4906 to guest port 80 2024-05-18 20:17:05 (60588): Enabling remote desktop for VM. 2024-05-18 20:17:05 (60588): Required extension pack not installed, remote desktop not enabled. 2024-05-18 20:17:05 (60588): Enabling shared directory for VM. 2024-05-18 20:17:06 (60588): Starting VM using VBoxManage interface. (boinc_55f75617201975d3, slot#8) 2024-05-18 20:17:11 (60588): Error in start VM for VM: -2147467259 Command: VBoxManage -q startvm "boinc_55f75617201975d3" --type headless Output: Waiting for VM "boinc_55f75617201975d3" to power on... VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole 2024-05-18 20:17:11 (60588): VM failed to start. 2024-05-18 20:17:11 (60588): Could not start 2024-05-18 20:17:11 (60588): ERROR: VM failed to start 2024-05-18 20:17:11 (60588): Powering off VM. 2024-05-18 20:17:11 (60588): Deregistering VM. (boinc_55f75617201975d3, slot#8) 2024-05-18 20:17:11 (60588): Removing network bandwidth throttle group from VM. 2024-05-18 20:17:12 (60588): Removing VM from VirtualBox. Hypervisor System Log: 00:00:02.131278 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_55f75617201975d3\boinc_55f75617201975d3.vbox" with version "1.16-windows" 00:00:02.139084 Saving settings file "C:\Users\Chad\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:02.427998 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_55f75617201975d3\boinc_55f75617201975d3.vbox" with version "1.16-windows" 00:00:02.718363 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_55f75617201975d3\boinc_55f75617201975d3.vbox" with version "1.16-windows" 00:00:03.002538 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_55f75617201975d3\boinc_55f75617201975d3.vbox" with version "1.16-windows" 00:00:03.260208 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_55f75617201975d3\boinc_55f75617201975d3.vbox" with version "1.16-windows" 00:00:03.595842 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_55f75617201975d3\boinc_55f75617201975d3.vbox" with version "1.16-windows" 00:00:03.854499 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_55f75617201975d3\boinc_55f75617201975d3.vbox" with version "1.16-windows" 00:00:04.156573 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_55f75617201975d3\boinc_55f75617201975d3.vbox" with version "1.16-windows" 00:00:04.435105 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_55f75617201975d3\boinc_55f75617201975d3.vbox" with version "1.16-windows" 00:00:04.719361 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_55f75617201975d3\boinc_55f75617201975d3.vbox" with version "1.16-windows" 00:00:04.974870 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_55f75617201975d3\boinc_55f75617201975d3.vbox" with version "1.16-windows" 00:00:05.244696 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_55f75617201975d3\boinc_55f75617201975d3.vbox" with version "1.16-windows" 00:00:05.517417 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_55f75617201975d3\boinc_55f75617201975d3.vbox" with version "1.16-windows" 00:00:05.782275 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_55f75617201975d3\boinc_55f75617201975d3.vbox" with version "1.16-windows" 00:00:06.051232 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_55f75617201975d3\boinc_55f75617201975d3.vbox" with version "1.16-windows" 00:00:06.319779 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_55f75617201975d3\boinc_55f75617201975d3.vbox" with version "1.16-windows" 00:00:06.853268 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:06.854190 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:06.854434 Saving settings file "C:\Users\Chad\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:06.899971 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_55f75617201975d3\boinc_55f75617201975d3.vbox" with version "1.16-windows" 00:00:07.124909 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_55f75617201975d3\boinc_55f75617201975d3.vbox" with version "1.16-windows" 00:00:07.395859 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.397738 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_55f75617201975d3\boinc_55f75617201975d3.vbox" with version "1.16-windows" 00:00:07.429705 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.437863 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_55f75617201975d3\boinc_55f75617201975d3.vbox" with version "1.16-windows" 00:00:07.448762 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_55f75617201975d3\boinc_55f75617201975d3.vbox" with version "1.16-windows" 00:00:07.665477 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.672274 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.672519 Saving settings file "C:\Users\Chad\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:07.704653 Saving settings file "C:\Users\Chad\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:07.719566 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_55f75617201975d3\boinc_55f75617201975d3.vbox" with version "1.16-windows" 00:00:07.939231 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_55f75617201975d3\boinc_55f75617201975d3.vbox" with version "1.16-windows" 00:00:08.220851 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_55f75617201975d3\boinc_55f75617201975d3.vbox" with version "1.16-windows" 00:00:08.756663 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_55f75617201975d3\boinc_55f75617201975d3.vbox" with version "1.16-windows" 00:00:09.019582 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.019819 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.036808 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:09.296688 Launched VM: 63948672 pid: 59160 (0xe718) frontend: headless name: boinc_55f75617201975d3 00:00:14.423682 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_55f75617201975d3\boinc_55f75617201975d3.vbox" with version "1.16-windows" 00:00:14.628076 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:14.763606 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_55f75617201975d3\boinc_55f75617201975d3.vbox" with version "1.16-windows" 00:00:15.009342 Saving settings file "C:\Users\Chad\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:20.077159 main VirtualBox: object deletion starts 00:00:20.077966 main HostDnsMonitor: shutting down ... 00:00:20.078063 main HostDnsMonitor: shut down 00:00:20.080768 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:20.081115 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: VBoxAuth Remote desktop ExtPack: Log history count: 3 Default frontend: Default audio driver: DirectSound Autostart database path: Default Guest Additions ISO: C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso Logging Level: all Proxy Mode: System Proxy URL: 2024-05-18 20:16:59 (60588): Command: VBoxManage -q list hostinfo Exit Code: 0 Output: Host Information: Host time: 2024-05-19T03:16:58.895000000Z Processor online count: 8 Processor count: 8 Processor online core count: 4 Processor core count: 4 Processor supports HW virtualization: no Processor supports PAE: yes Processor supports long mode: yes Processor supports nested paging: no Processor supports unrestricted guest: no Processor supports nested HW virtualization: no Processor#0 speed: unknown Processor#0 description: Intel(R) Core(TM) i7-4700MQ CPU @ 2.40GHz Processor#1 speed: unknown Processor#1 description: Intel(R) Core(TM) i7-4700MQ CPU @ 2.40GHz Processor#2 speed: unknown Processor#2 description: Intel(R) Core(TM) i7-4700MQ CPU @ 2.40GHz Processor#3 speed: unknown Processor#3 description: Intel(R) Core(TM) i7-4700MQ CPU @ 2.40GHz Processor#4 speed: unknown Processor#4 description: Intel(R) Core(TM) i7-4700MQ CPU @ 2.40GHz Processor#5 speed: unknown Processor#5 description: Intel(R) Core(TM) i7-4700MQ CPU @ 2.40GHz Processor#6 speed: unknown Processor#6 description: Intel(R) Core(TM) i7-4700MQ CPU @ 2.40GHz Processor#7 speed: unknown Processor#7 description: Intel(R) Core(TM) i7-4700MQ CPU @ 2.40GHz Memory size: 7912 MByte Memory available: 1964 MByte Operating system: Windows 10 Operating system version: 10.0.19045 2024-05-18 20:16:59 (60588): Command: VBoxManage -q showvminfo "boinc_55f75617201975d3" --machinereadable Exit Code: -2135228415 Output: VBoxManage.exe: error: Could not find a registered machine named 'boinc_55f75617201975d3' VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2715 of file VBoxManageInfo.cpp 2024-05-18 20:16:59 (60588): Command: VBoxManage -q createvm --name "boinc_55f75617201975d3" --basefolder "C:\ProgramData\BOINC\slots\8" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_55f75617201975d3' is created and registered. UUID: df872bfc-4ba1-48f1-ace8-f8e4c71dfcc1 Settings file: 'C:\ProgramData\BOINC\slots\8\boinc_55f75617201975d3\boinc_55f75617201975d3.vbox' 2024-05-18 20:16:59 (60588): Command: VBoxManage -q modifyvm "boinc_55f75617201975d3" --description "CMS_3185046_1716086858.920452_0" Exit Code: 0 Output: 2024-05-18 20:17:00 (60588): Command: VBoxManage -q modifyvm "boinc_55f75617201975d3" --memory 4584 Exit Code: 0 Output: 2024-05-18 20:17:00 (60588): Command: VBoxManage -q modifyvm "boinc_55f75617201975d3" --cpus 4 Exit Code: 0 Output: 2024-05-18 20:17:00 (60588): Command: VBoxManage -q modifyvm "boinc_55f75617201975d3" --acpi on --ioapic on --rtcuseutc off Exit Code: 0 Output: 2024-05-18 20:17:01 (60588): Command: VBoxManage -q modifyvm "boinc_55f75617201975d3" --vram 16 --graphicscontroller VBoxVGA Exit Code: 0 Output: 2024-05-18 20:17:01 (60588): Command: VBoxManage -q modifyvm "boinc_55f75617201975d3" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2024-05-18 20:17:01 (60588): Command: VBoxManage -q modifyvm "boinc_55f75617201975d3" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2024-05-18 20:17:01 (60588): Command: VBoxManage -q modifyvm "boinc_55f75617201975d3" --cableconnected1 on Exit Code: 0 Output: 2024-05-18 20:17:02 (60588): Command: VBoxManage -q modifyvm "boinc_55f75617201975d3" --usb off Exit Code: 0 Output: 2024-05-18 20:17:02 (60588): Command: VBoxManage -q modifyvm "boinc_55f75617201975d3" --uart1 off --uart2 off Exit Code: 0 Output: 2024-05-18 20:17:02 (60588): Command: VBoxManage -q modifyvm "boinc_55f75617201975d3" --lpt1 off --lpt2 off Exit Code: 0 Output: 2024-05-18 20:17:03 (60588): Command: VBoxManage -q modifyvm "boinc_55f75617201975d3" --audio none Exit Code: 0 Output: 2024-05-18 20:17:03 (60588): Command: VBoxManage -q modifyvm "boinc_55f75617201975d3" --clipboard disabled Exit Code: 0 Output: 2024-05-18 20:17:03 (60588): Command: VBoxManage -q modifyvm "boinc_55f75617201975d3" --draganddrop disabled Exit Code: 0 Output: 2024-05-18 20:17:03 (60588): Command: VBoxManage -q storagectl "boinc_55f75617201975d3" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2024-05-18 20:17:04 (60588): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2024_04_29_prod.vdi" Exit Code: 0 Output: UUID: 461abfaf-39ef-4b91-89ba-53cae0787c5e Parent UUID: base State: created Type: normal (base) Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\CMS_2024_04_29_prod.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 3853 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2024-05-18 20:17:04 (60588): Command: VBoxManage -q storageattach "boinc_55f75617201975d3" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2024_04_29_prod.vdi" Exit Code: 0 Output: 2024-05-18 20:17:04 (60588): Command: VBoxManage -q storageattach "boinc_55f75617201975d3" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none Exit Code: 0 Output: 2024-05-18 20:17:04 (60588): Command: VBoxManage -q storageattach "boinc_55f75617201975d3" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2024_04_29_prod.vdi" Exit Code: 0 Output: 2024-05-18 20:17:05 (60588): Command: VBoxManage -q storageattach "boinc_55f75617201975d3" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2024-05-18 20:17:05 (60588): Command: VBoxManage -q bandwidthctl "boinc_55f75617201975d3" add "boinc_55f75617201975d3_net" --type network --limit 1024G Exit Code: 0 Output: 2024-05-18 20:17:05 (60588): Command: VBoxManage -q modifyvm "boinc_55f75617201975d3" --natpf1 ",tcp,127.0.0.1,4906,,80" Exit Code: 0 Output: 2024-05-18 20:17:05 (60588): Command: VBoxManage -q list extpacks Exit Code: 0 Output: Extension Packs: 0 2024-05-18 20:17:06 (60588): Command: VBoxManage -q sharedfolder add "boinc_55f75617201975d3" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\8/shared" Exit Code: 0 Output: 2024-05-18 20:17:11 (60588): Command: VBoxManage -q startvm "boinc_55f75617201975d3" --type headless Exit Code: -2147467259 Output: Waiting for VM "boinc_55f75617201975d3" to power on... VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole 2024-05-18 20:17:11 (60588): Command: VBoxManage -q snapshot "boinc_55f75617201975d3" list Exit Code: -108 Output: This machine does not have any snapshots 2024-05-18 20:17:12 (60588): Command: VBoxManage -q bandwidthctl "boinc_55f75617201975d3" remove "boinc_55f75617201975d3_net" Exit Code: 0 Output: 2024-05-18 20:17:12 (60588): Command: VBoxManage -q unregistervm "boinc_55f75617201975d3" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 2024-05-18 20:17:18 (60588): called boinc_finish(-2147467259) </stderr_txt> ]]>
©2024 CERN