Name CMS_105493_1715286218.312051_0
Workunit 222888888
Created 9 May 2024, 20:23:40 UTC
Sent 9 May 2024, 20:39:05 UTC
Report deadline 9 Jun 2024, 20:39:05 UTC
Received 31 May 2024, 5:34:14 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status -2147467259 (0x80004005) Unknown error code
Computer ID 10838680
Run time 4 sec
CPU time 0 sec
Validate state Invalid
Credit 0.00
Device peak FLOPS 16.39 GFLOPS
Application version CMS Simulation v70.30 (vbox64_mt_mcore_cms)
windows_x86_64
Peak working set size 11.30 MB
Peak swap size 6.40 MB
Peak disk usage 8.92 KB

Stderr output

<core_client_version>7.24.1</core_client_version>
<![CDATA[
<message>
Unspecified error
 (0x80004005) - exit code 2147500037 (0x80004005)</message>
<stderr_txt>
2024-05-30 22:30:57 (10552): vboxwrapper version 26207
2024-05-30 22:30:57 (10552): BOINC client version: 7.24.1
2024-05-30 22:30:58 (10552): Detected: VirtualBox VboxManage Interface (Version: 7.0.12)
2024-05-30 22:30:59 (10552): Detected: Heartbeat check (file: 'heartbeat' every 1200.000000 seconds)
2024-05-30 22:30:59 (10552): Successfully copied 'init_data.xml' to the shared directory.
2024-05-30 22:30:59 (10552): Create VM. (boinc_e75e764fc6f3a4a8, slot#8)
2024-05-30 22:30:59 (10552): Setting Memory Size for VM. (4584MB)
2024-05-30 22:31:00 (10552): Setting CPU Count for VM. (4)
2024-05-30 22:31:00 (10552): Setting Chipset Options for VM.
2024-05-30 22:31:00 (10552): Setting Graphics Controller Options for VM.
2024-05-30 22:31:01 (10552): Setting Boot Options for VM.
2024-05-30 22:31:01 (10552): Setting Network Configuration for NAT.
2024-05-30 22:31:01 (10552): Enabling VM Network Access.
2024-05-30 22:31:01 (10552): Disabling USB Support for VM.
2024-05-30 22:31:02 (10552): Disabling COM Port Support for VM.
2024-05-30 22:31:02 (10552): Disabling LPT Port Support for VM.
2024-05-30 22:31:02 (10552): Disabling Audio Support for VM.
2024-05-30 22:31:02 (10552): Disabling Clipboard Support for VM.
2024-05-30 22:31:03 (10552): Disabling Drag and Drop Support for VM.
2024-05-30 22:31:03 (10552): Adding storage controller(s) to VM.
2024-05-30 22:31:03 (10552): Adding virtual disk drive to VM. (CMS_2024_04_29_prod.vdi)
2024-05-30 22:31:05 (10552): Adding VirtualBox Guest Additions to VM.
2024-05-30 22:31:06 (10552): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2024-05-30 22:31:06 (10552): forwarding host port 63537 to guest port 80
2024-05-30 22:31:06 (10552): Enabling remote desktop for VM.
2024-05-30 22:31:07 (10552): Enabling shared directory for VM.
2024-05-30 22:31:07 (10552): Starting VM using VBoxManage interface. (boinc_e75e764fc6f3a4a8, slot#8)
2024-05-30 22:31:13 (10552): Error in start VM for VM: -2147467259
Command:
VBoxManage -q startvm "boinc_e75e764fc6f3a4a8" --type headless
Output:
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole
Waiting for VM "boinc_e75e764fc6f3a4a8" to power on...

2024-05-30 22:31:13 (10552): VM failed to start.
2024-05-30 22:31:13 (10552): Could not start 
2024-05-30 22:31:13 (10552): ERROR: VM failed to start
2024-05-30 22:31:13 (10552): Powering off VM.
2024-05-30 22:31:13 (10552): Deregistering VM. (boinc_e75e764fc6f3a4a8, slot#8)
2024-05-30 22:31:13 (10552): Removing network bandwidth throttle group from VM.
2024-05-30 22:31:13 (10552): Removing VM from VirtualBox.

    Hypervisor System Log:

00:00:08.639609          Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_1a70782873bc56c6\boinc_1a70782873bc56c6.vbox" with version "1.19-windows"
00:00:08.644475          Finished saving settings file "C:\ProgramData\BOINC\slots\7\boinc_1a70782873bc56c6\boinc_1a70782873bc56c6.vbox"
00:00:08.891667          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.892139          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.892784          Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_1a70782873bc56c6\boinc_1a70782873bc56c6.vbox" with version "1.19-windows"
00:00:08.899284          Finished saving settings file "C:\ProgramData\BOINC\slots\7\boinc_1a70782873bc56c6\boinc_1a70782873bc56c6.vbox"
00:00:08.955680          Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_e75e764fc6f3a4a8\boinc_e75e764fc6f3a4a8.vbox" with version "1.19-windows"
00:00:08.960367          Finished saving settings file "C:\ProgramData\BOINC\slots\8\boinc_e75e764fc6f3a4a8\boinc_e75e764fc6f3a4a8.vbox"
00:00:09.158104          Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_1a70782873bc56c6\boinc_1a70782873bc56c6.vbox" with version "1.19-windows"
00:00:09.165177          Finished saving settings file "C:\ProgramData\BOINC\slots\7\boinc_1a70782873bc56c6\boinc_1a70782873bc56c6.vbox"
00:00:09.219679          Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_e75e764fc6f3a4a8\boinc_e75e764fc6f3a4a8.vbox" with version "1.19-windows"
00:00:09.224481          Finished saving settings file "C:\ProgramData\BOINC\slots\8\boinc_e75e764fc6f3a4a8\boinc_e75e764fc6f3a4a8.vbox"
00:00:09.428090          Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_1a70782873bc56c6\boinc_1a70782873bc56c6.vbox" with version "1.19-windows"
00:00:09.438750          Finished saving settings file "C:\ProgramData\BOINC\slots\7\boinc_1a70782873bc56c6\boinc_1a70782873bc56c6.vbox"
00:00:09.530170          ERROR [COM]: aRC=VBOX_E_NOT_SUPPORTED (0x80bb0009) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This VM is not encrypted}, preserve=false aResultDetail=0
00:00:09.538537          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:09.538621          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:09.694283          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:09.958529          Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_1a70782873bc56c6\boinc_1a70782873bc56c6.vbox" with version "1.19-windows"
00:00:09.965574          Finished saving settings file "C:\ProgramData\BOINC\slots\7\boinc_1a70782873bc56c6\boinc_1a70782873bc56c6.vbox"
00:00:10.028482          Launched VM: 4081391424 pid: 8592 (0x2190) frontend: headless name: boinc_e75e764fc6f3a4a8
00:00:10.231350          Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_1a70782873bc56c6\boinc_1a70782873bc56c6.vbox" with version "1.19-windows"
00:00:10.239977          Finished saving settings file "C:\ProgramData\BOINC\slots\7\boinc_1a70782873bc56c6\boinc_1a70782873bc56c6.vbox"
00:00:10.484642          ERROR [COM]: aRC=VBOX_E_NOT_SUPPORTED (0x80bb0009) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This VM is not encrypted}, preserve=false aResultDetail=0
00:00:10.491892          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:10.491979          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:10.696777          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:11.016794          Launched VM: 4078555424 pid: 10484 (0x28f4) frontend: headless name: boinc_1a70782873bc56c6
00:00:15.245766          Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_e75e764fc6f3a4a8\boinc_e75e764fc6f3a4a8.vbox" with version "1.19-windows"
00:00:15.257505          Finished saving settings file "C:\ProgramData\BOINC\slots\8\boinc_e75e764fc6f3a4a8\boinc_e75e764fc6f3a4a8.vbox"
00:00:15.339068          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:15.664549          Saving settings file "C:\Users\grise\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:15.670707          Finished saving settings file "C:\Users\grise\.VirtualBox\VirtualBox.xml"
00:00:15.670913          Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_1a70782873bc56c6\boinc_1a70782873bc56c6.vbox" with version "1.19-windows"
00:00:15.674935          Finished saving settings file "C:\ProgramData\BOINC\slots\7\boinc_1a70782873bc56c6\boinc_1a70782873bc56c6.vbox"
00:00:15.676054 DeleteVM Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_1a70782873bc56c6\boinc_1a70782873bc56c6.vbox" with version "1.19-windows"
00:00:15.680190 DeleteVM Finished saving settings file "C:\ProgramData\BOINC\slots\7\boinc_1a70782873bc56c6\boinc_1a70782873bc56c6.vbox"
00:00:16.209107          Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_1a70782873bc56c6\boinc_1a70782873bc56c6.vbox" with version "1.19-windows"
00:00:16.215968          Finished saving settings file "C:\ProgramData\BOINC\slots\7\boinc_1a70782873bc56c6\boinc_1a70782873bc56c6.vbox"
00:00:16.298465          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:16.630617          Saving settings file "C:\Users\grise\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:16.635356          Finished saving settings file "C:\Users\grise\.VirtualBox\VirtualBox.xml"
00:00:16.635416          Saving settings file "C:\Users\grise\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:16.639615          Finished saving settings file "C:\Users\grise\.VirtualBox\VirtualBox.xml"
00:00:16.640502 DeleteVM Saving settings file "C:\Users\grise\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:16.648196 DeleteVM Finished saving settings file "C:\Users\grise\.VirtualBox\VirtualBox.xml"
00:00:21.650190 main     VirtualBox: object deletion starts
00:00:21.651434 main     HostDnsMonitor: shutting down ...
00:00:21.651503 main     HostDnsMonitor: shut down
00:00:21.653357 Watcher  ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0
00:00:21.653692 main     VirtualBox: object deleted

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:



2024-05-30 22:31:00 (10552): 
Command: VBoxManage -q modifyvm "boinc_e75e764fc6f3a4a8" --memory 4584 
Exit Code: 0
Output:

2024-05-30 22:31:00 (10552): 
Command: VBoxManage -q modifyvm "boinc_e75e764fc6f3a4a8" --cpus 4 
Exit Code: 0
Output:

2024-05-30 22:31:00 (10552): 
Command: VBoxManage -q modifyvm "boinc_e75e764fc6f3a4a8" --acpi on --ioapic on --rtcuseutc off 
Exit Code: 0
Output:

2024-05-30 22:31:01 (10552): 
Command: VBoxManage -q modifyvm "boinc_e75e764fc6f3a4a8" --vram 16 --graphicscontroller VBoxVGA 
Exit Code: 0
Output:

2024-05-30 22:31:01 (10552): 
Command: VBoxManage -q modifyvm "boinc_e75e764fc6f3a4a8" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2024-05-30 22:31:01 (10552): 
Command: VBoxManage -q modifyvm "boinc_e75e764fc6f3a4a8" --nic1 nat --natdnsproxy1 on --cableconnected1 off 
Exit Code: 0
Output:

2024-05-30 22:31:01 (10552): 
Command: VBoxManage -q modifyvm "boinc_e75e764fc6f3a4a8" --cableconnected1 on 
Exit Code: 0
Output:

2024-05-30 22:31:02 (10552): 
Command: VBoxManage -q modifyvm "boinc_e75e764fc6f3a4a8" --usb off 
Exit Code: 0
Output:

2024-05-30 22:31:02 (10552): 
Command: VBoxManage -q modifyvm "boinc_e75e764fc6f3a4a8" --uart1 off --uart2 off 
Exit Code: 0
Output:

2024-05-30 22:31:02 (10552): 
Command: VBoxManage -q modifyvm "boinc_e75e764fc6f3a4a8" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2024-05-30 22:31:02 (10552): 
Command: VBoxManage -q modifyvm "boinc_e75e764fc6f3a4a8" --audio-enabled off 
Exit Code: 0
Output:

2024-05-30 22:31:03 (10552): 
Command: VBoxManage -q modifyvm "boinc_e75e764fc6f3a4a8" --clipboard disabled 
Exit Code: 0
Output:

2024-05-30 22:31:03 (10552): 
Command: VBoxManage -q modifyvm "boinc_e75e764fc6f3a4a8" --draganddrop disabled 
Exit Code: 0
Output:

2024-05-30 22:31:03 (10552): 
Command: VBoxManage -q storagectl "boinc_e75e764fc6f3a4a8" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2024-05-30 22:31:03 (10552): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2024_04_29_prod.vdi" 
Exit Code: 0
Output:
UUID:           461abfaf-39ef-4b91-89ba-53cae0787c5e
Parent UUID:    base
State:          created
Type:           multiattach
Location:       C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\CMS_2024_04_29_prod.vdi
Storage format: VDI
Format variant: dynamic default
Capacity:       20480 MBytes
Size on disk:   3853 MBytes
Encryption:     disabled
Property:       AllocationBlockSize=1048576

2024-05-30 22:31:04 (10552): 
Command: VBoxManage -q storageattach "boinc_e75e764fc6f3a4a8" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2024_04_29_prod.vdi" 
Exit Code: -2135228409
Output:
VBoxManage.exe: error: Cannot attach medium 'C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\CMS_2024_04_29_prod.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later
VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown
VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 785 of file VBoxManageStorageController.cpp

2024-05-30 22:31:04 (10552): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2024_04_29_prod.vdi" 
Exit Code: 0
Output:
UUID:           461abfaf-39ef-4b91-89ba-53cae0787c5e
Parent UUID:    base
State:          created
Type:           multiattach
Location:       C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\CMS_2024_04_29_prod.vdi
Storage format: VDI
Format variant: dynamic default
Capacity:       20480 MBytes
Size on disk:   3853 MBytes
Encryption:     disabled
Property:       AllocationBlockSize=1048576

2024-05-30 22:31:04 (10552): 
Command: VBoxManage -q closemedium disk "C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\CMS_2024_04_29_prod.vdi" 
Exit Code: 0
Output:

2024-05-30 22:31:05 (10552): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2024_04_29_prod.vdi" 
Exit Code: 0
Output:
UUID:           461abfaf-39ef-4b91-89ba-53cae0787c5e
Parent UUID:    base
State:          created
Type:           normal (base)
Location:       C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\CMS_2024_04_29_prod.vdi
Storage format: VDI
Format variant: dynamic default
Capacity:       20480 MBytes
Size on disk:   3853 MBytes
Encryption:     disabled
Property:       AllocationBlockSize=1048576

2024-05-30 22:31:05 (10552): 
Command: VBoxManage -q storageattach "boinc_e75e764fc6f3a4a8" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2024_04_29_prod.vdi" 
Exit Code: 0
Output:

2024-05-30 22:31:05 (10552): 
Command: VBoxManage -q storageattach "boinc_e75e764fc6f3a4a8" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none 
Exit Code: 0
Output:

2024-05-30 22:31:05 (10552): 
Command: VBoxManage -q storageattach "boinc_e75e764fc6f3a4a8" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2024_04_29_prod.vdi" 
Exit Code: 0
Output:

2024-05-30 22:31:06 (10552): 
Command: VBoxManage -q storageattach "boinc_e75e764fc6f3a4a8" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2024-05-30 22:31:06 (10552): 
Command: VBoxManage -q bandwidthctl "boinc_e75e764fc6f3a4a8" add "boinc_e75e764fc6f3a4a8_net" --type network --limit 1024G 
Exit Code: 0
Output:

2024-05-30 22:31:06 (10552): 
Command: VBoxManage -q modifyvm "boinc_e75e764fc6f3a4a8" --natpf1 ",tcp,127.0.0.1,63537,,80" 
Exit Code: 0
Output:

2024-05-30 22:31:06 (10552): 
Command: VBoxManage -q list extpacks
Exit Code: 0
Output:
Extension Packs: 1
Pack no. 0:   Oracle VM VirtualBox Extension Pack
Version:        7.0.12
Revision:       159484
Edition:        
Description:    Oracle Cloud Infrastructure integration, Host Webcam, VirtualBox RDP, PXE ROM, Disk Encryption, NVMe, full VM encryption.
VRDE Module:    VBoxVRDP
Crypto Module:  VBoxPuelCrypto
Usable:         true
Why unusable:   

2024-05-30 22:31:07 (10552): 
Command: VBoxManage -q modifyvm "boinc_e75e764fc6f3a4a8" --vrde on --vrdeextpack default --vrdeauthlibrary default --vrdeauthtype null --vrdeport 63538 
Exit Code: 0
Output:

2024-05-30 22:31:07 (10552): 
Command: VBoxManage -q sharedfolder add "boinc_e75e764fc6f3a4a8" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\8/shared"
Exit Code: 0
Output:

2024-05-30 22:31:13 (10552): 
Command: VBoxManage -q startvm "boinc_e75e764fc6f3a4a8" --type headless
Exit Code: -2147467259
Output:
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole
Waiting for VM "boinc_e75e764fc6f3a4a8" to power on...

2024-05-30 22:31:13 (10552): 
Command: VBoxManage -q snapshot "boinc_e75e764fc6f3a4a8" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2024-05-30 22:31:13 (10552): 
Command: VBoxManage -q bandwidthctl "boinc_e75e764fc6f3a4a8" remove "boinc_e75e764fc6f3a4a8_net" 
Exit Code: 0
Output:
VBoxManage.exe: error: Bandwidth groups cannot be deleted while the VM is running

2024-05-30 22:31:13 (10552): 
Command: VBoxManage -q unregistervm "boinc_e75e764fc6f3a4a8" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

2024-05-30 22:31:20 (10552): called boinc_finish(-2147467259)

</stderr_txt>
]]>