Name CMS_2492522_1714837790.790124_0
Workunit 222758026
Created 4 May 2024, 15:49:51 UTC
Sent 4 May 2024, 16:11:36 UTC
Report deadline 4 Jun 2024, 16:11:36 UTC
Received 21 May 2024, 18:58:06 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status -2147467259 (0x80004005) Unknown error code
Computer ID 10560099
Run time 24 sec
CPU time 0 sec
Validate state Invalid
Credit 0.00
Device peak FLOPS 13.36 GFLOPS
Application version CMS Simulation v70.30 (vbox64_mt_mcore_cms)
windows_x86_64
Peak working set size 11.16 MB
Peak swap size 6.26 MB
Peak disk usage 9.41 KB

Stderr output

<core_client_version>7.24.1</core_client_version>
<![CDATA[
<message>
Erreur non sp�cifi�e
 (0x80004005) - exit code 2147500037 (0x80004005)</message>
<stderr_txt>
2024-05-21 20:26:50 (700): vboxwrapper version 26207
2024-05-21 20:26:50 (700): BOINC client version: 7.24.1
2024-05-21 20:26:51 (700): Detected: VirtualBox VboxManage Interface (Version: 7.0.18)
2024-05-21 20:26:51 (700): Detected: Heartbeat check (file: 'heartbeat' every 1200.000000 seconds)
2024-05-21 20:26:51 (700): Successfully copied 'init_data.xml' to the shared directory.
2024-05-21 20:26:52 (700): Create VM. (boinc_1765182ccd0b2ba8, slot#6)
2024-05-21 20:26:52 (700): Setting Memory Size for VM. (3688MB)
2024-05-21 20:26:53 (700): Setting CPU Count for VM. (3)
2024-05-21 20:26:53 (700): Setting Chipset Options for VM.
2024-05-21 20:26:53 (700): Setting Graphics Controller Options for VM.
2024-05-21 20:26:53 (700): Setting Boot Options for VM.
2024-05-21 20:26:54 (700): Setting Network Configuration for NAT.
2024-05-21 20:26:54 (700): Enabling VM Network Access.
2024-05-21 20:26:54 (700): Disabling USB Support for VM.
2024-05-21 20:26:54 (700): Disabling COM Port Support for VM.
2024-05-21 20:26:55 (700): Disabling LPT Port Support for VM.
2024-05-21 20:26:55 (700): Disabling Audio Support for VM.
2024-05-21 20:26:55 (700): Disabling Clipboard Support for VM.
2024-05-21 20:26:56 (700): Disabling Drag and Drop Support for VM.
2024-05-21 20:26:56 (700): Adding storage controller(s) to VM.
2024-05-21 20:26:56 (700): Adding virtual disk drive to VM. (CMS_2024_04_29_prod.vdi)
2024-05-21 20:26:58 (700): Adding VirtualBox Guest Additions to VM.
2024-05-21 20:26:58 (700): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2024-05-21 20:26:59 (700): forwarding host port 20473 to guest port 80
2024-05-21 20:26:59 (700): Enabling remote desktop for VM.
2024-05-21 20:27:00 (700): Enabling shared directory for VM.
2024-05-21 20:27:01 (700): Starting VM using VBoxManage interface. (boinc_1765182ccd0b2ba8, slot#6)
2024-05-21 20:27:06 (700): Error in start VM for VM: -2147467259
Command:
VBoxManage -q startvm "boinc_1765182ccd0b2ba8" --type headless
Output:
VBoxManage.exe: error: Failed to launch the Remote Desktop Extension server (VERR_GENERAL_FAILURE)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole
Waiting for VM "boinc_1765182ccd0b2ba8" to power on...

2024-05-21 20:27:06 (700): VM failed to start.
2024-05-21 20:27:06 (700): Could not start 
2024-05-21 20:27:06 (700): ERROR: VM failed to start
2024-05-21 20:27:06 (700): Powering off VM.
2024-05-21 20:27:06 (700): Deregistering VM. (boinc_1765182ccd0b2ba8, slot#6)
2024-05-21 20:27:06 (700): Removing network bandwidth throttle group from VM.
2024-05-21 20:27:06 (700): Removing VM from VirtualBox.

    Hypervisor System Log:

00:00:08.568874          Saving settings file "F:\ProgramData\BOINC\slots\6\boinc_1765182ccd0b2ba8\boinc_1765182ccd0b2ba8.vbox" with version "1.19-windows"
00:00:08.578779          Finished saving settings file "F:\ProgramData\BOINC\slots\6\boinc_1765182ccd0b2ba8\boinc_1765182ccd0b2ba8.vbox"
00:00:09.091126          Saving settings file "F:\ProgramData\BOINC\slots\6\boinc_1765182ccd0b2ba8\boinc_1765182ccd0b2ba8.vbox" with version "1.19-windows"
00:00:09.106836          Finished saving settings file "F:\ProgramData\BOINC\slots\6\boinc_1765182ccd0b2ba8\boinc_1765182ccd0b2ba8.vbox"
00:00:09.356623          Saving settings file "F:\ProgramData\BOINC\slots\6\boinc_1765182ccd0b2ba8\boinc_1765182ccd0b2ba8.vbox" with version "1.19-windows"
00:00:09.373502          Finished saving settings file "F:\ProgramData\BOINC\slots\6\boinc_1765182ccd0b2ba8\boinc_1765182ccd0b2ba8.vbox"
00:00:09.746709          ERROR [COM]: aRC=VBOX_E_NOT_SUPPORTED (0x80bb0009) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This VM is not encrypted}, preserve=false aResultDetail=0
00:00:09.754371          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:09.754459          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:10.076412          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:10.413339          Launched VM: 3502446608 pid: 18200 (0x4718) frontend: headless name: boinc_1765182ccd0b2ba8
00:00:15.522813          Saving settings file "F:\ProgramData\BOINC\slots\6\boinc_1765182ccd0b2ba8\boinc_1765182ccd0b2ba8.vbox" with version "1.19-windows"
00:00:15.534373          Finished saving settings file "F:\ProgramData\BOINC\slots\6\boinc_1765182ccd0b2ba8\boinc_1765182ccd0b2ba8.vbox"
00:00:15.632087          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:15.980981          ERROR [COM]: aRC=VBOX_E_INVALID_OBJECT_STATE (0x80bb0007) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={Cannot unregister the machine 'boinc_1765182ccd0b2ba8' while it is locked}, preserve=false aResultDetail=0
00:00:17.256636          Saving settings file "C:\Users\ZEUS\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:17.267308          Finished saving settings file "C:\Users\ZEUS\.VirtualBox\VirtualBox.xml"
00:00:17.267443          Saving settings file "C:\Users\ZEUS\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:17.278434          Finished saving settings file "C:\Users\ZEUS\.VirtualBox\VirtualBox.xml"
00:00:17.279256 DeleteVM Saving settings file "C:\Users\ZEUS\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:17.289793 DeleteVM Finished saving settings file "C:\Users\ZEUS\.VirtualBox\VirtualBox.xml"
00:00:22.303312 main     VirtualBox: object deletion starts
00:00:22.303386 main     ERROR [COM]: aRC=VBOX_E_OBJECT_IN_USE (0x80bb000c) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Medium 'F:\VHDs\LECO\LECO CornerStone\LECO CornerStone.vdi' cannot be closed because it is still attached to 1 virtual machines}, preserve=false aResultDetail=0
00:00:22.303888 main     ERROR [COM]: aRC=VBOX_E_OBJECT_IN_USE (0x80bb000c) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Medium 'F:\VHDs\LECO\Virtual PC XP\Windows XPM.vhd' cannot be closed because it is still attached to 1 virtual machines}, preserve=false aResultDetail=0
00:00:22.304303 main     ERROR [COM]: aRC=VBOX_E_OBJECT_IN_USE (0x80bb000c) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Medium '\\nas-hermes\VHDs\Photos - Pro\Photos - Pro.vdi' cannot be closed because it is still attached to 1 virtual machines}, preserve=false aResultDetail=0
00:00:22.305236 main     ERROR [COM]: aRC=VBOX_E_OBJECT_IN_USE (0x80bb000c) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Medium 'I:\VirtualBox VMs\Web\Windows 7 Professionnel (WordPress)\Windows 7 Professionnel (WordPress) 2.vdi' cannot be closed because it is still attached to 1 virtual machines}, preserve=false aResultDetail=0
00:00:22.306012 main     ERROR [COM]: aRC=VBOX_E_OBJECT_IN_USE (0x80bb000c) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Medium '\\nas-hermes\VHDs\Linux Mint Mate\Linux Mint Mate.vdi' cannot be closed because it is still attached to 1 virtual machines}, preserve=false aResultDetail=0
00:00:22.306426 main     ERROR [COM]: aRC=VBOX_E_OBJECT_IN_USE (0x80bb000c) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Medium '\\nas-hermes\VHDs\Photos - Pro V2.vdi' cannot be closed because it is still attached to 1 virtual machines}, preserve=false aResultDetail=0
00:00:22.307184 main     ERROR [COM]: aRC=VBOX_E_OBJECT_IN_USE (0x80bb000c) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Medium 'I:\VirtualBox VMs\Windows 7\Windows 7 Int&#195;&#169;grale x64\Windows 7 Int&#195;&#169;grale x64.vdi' cannot be closed because it is still attached to 1 virtual machines}, preserve=false aResultDetail=0
00:00:22.307601 main     ERROR [COM]: aRC=VBOX_E_OBJECT_IN_USE (0x80bb000c) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Medium 'I:\VirtualBox VMs\Windows 2012 R2\Windows 2012 R2.vdi' cannot be closed because it is still attached to 1 virtual machines}, preserve=false aResultDetail=0
00:00:22.308027 main     ERROR [COM]: aRC=VBOX_E_OBJECT_IN_USE (0x80bb000c) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Medium 'I:\VirtualBox VMs\Windows 10 Pro\Windows 10 Pro.vdi' cannot be closed because it is still attached to 1 virtual machines}, preserve=false aResultDetail=0
00:00:22.308440 main     ERROR [COM]: aRC=VBOX_E_OBJECT_IN_USE (0x80bb000c) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Medium 'I:\VirtualBox VMs\Windows 7 Pro x64\Windows 7 Pro x64-disk001.vmdk' cannot be closed because it is still attached to 1 virtual machines}, preserve=false aResultDetail=0
00:00:22.308872 main     ERROR [COM]: aRC=VBOX_E_OBJECT_IN_USE (0x80bb000c) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Medium 'I:\VirtualBox VMs\W7Px64\En Cours de TEST\Windows 7 Pro x64 - TEST\Windows 7 Pro x64.vdi' cannot be closed because it is still attached to 1 virtual machines}, preserve=false aResultDetail=0
00:00:22.309289 main     ERROR [COM]: aRC=VBOX_E_OBJECT_IN_USE (0x80bb000c) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Medium 'I:\VirtualBox VMs\Windows 10 WS\Windows 10 Pro WorkStation\Windows 10 Pro WorkStation.vdi' cannot be closed because it is still attached to 1 virtual machines}, preserve=false aResultDetail=0
00:00:22.310041 main     ERROR [COM]: aRC=VBOX_E_OBJECT_IN_USE (0x80bb000c) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Medium 'I:\VirtualBox VMs\Windows 2019\Windows 2019 Serveur\Windows 2019 Serveur.vdi' cannot be closed because it is still attached to 1 virtual machines}, preserve=false aResultDetail=0
00:00:22.311755 main     HostDnsMonitor: shutting down ...
00:00:22.311792 main     HostDnsMonitor: shut down
00:00:22.314152 Watcher  ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0
00:00:22.314594 main     VirtualBox: object deleted

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

 VBoxManage -q modifyvm "boinc_1765182ccd0b2ba8" --vram 16 --graphicscontroller VBoxVGA 
Exit Code: 0
Output:

2024-05-21 20:26:54 (700): 
Command: VBoxManage -q modifyvm "boinc_1765182ccd0b2ba8" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2024-05-21 20:26:54 (700): 
Command: VBoxManage -q modifyvm "boinc_1765182ccd0b2ba8" --nic1 nat --natdnsproxy1 on --cableconnected1 off 
Exit Code: 0
Output:

2024-05-21 20:26:54 (700): 
Command: VBoxManage -q modifyvm "boinc_1765182ccd0b2ba8" --cableconnected1 on 
Exit Code: 0
Output:

2024-05-21 20:26:54 (700): 
Command: VBoxManage -q modifyvm "boinc_1765182ccd0b2ba8" --usb off 
Exit Code: 0
Output:

2024-05-21 20:26:55 (700): 
Command: VBoxManage -q modifyvm "boinc_1765182ccd0b2ba8" --uart1 off --uart2 off 
Exit Code: 0
Output:

2024-05-21 20:26:55 (700): 
Command: VBoxManage -q modifyvm "boinc_1765182ccd0b2ba8" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2024-05-21 20:26:55 (700): 
Command: VBoxManage -q modifyvm "boinc_1765182ccd0b2ba8" --audio-enabled off 
Exit Code: 0
Output:

2024-05-21 20:26:56 (700): 
Command: VBoxManage -q modifyvm "boinc_1765182ccd0b2ba8" --clipboard disabled 
Exit Code: 0
Output:

2024-05-21 20:26:56 (700): 
Command: VBoxManage -q modifyvm "boinc_1765182ccd0b2ba8" --draganddrop disabled 
Exit Code: 0
Output:

2024-05-21 20:26:56 (700): 
Command: VBoxManage -q storagectl "boinc_1765182ccd0b2ba8" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2024-05-21 20:26:56 (700): 
Command: VBoxManage -q showhdinfo "F:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2024_04_29_prod.vdi" 
Exit Code: 0
Output:
UUID:           461abfaf-39ef-4b91-89ba-53cae0787c5e
Parent UUID:    base
State:          created
Type:           multiattach
Location:       F:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\CMS_2024_04_29_prod.vdi
Storage format: VDI
Format variant: dynamic default
Capacity:       20480 MBytes
Size on disk:   3853 MBytes
Encryption:     disabled
Property:       AllocationBlockSize=1048576

2024-05-21 20:26:57 (700): 
Command: VBoxManage -q storageattach "boinc_1765182ccd0b2ba8" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "F:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2024_04_29_prod.vdi" 
Exit Code: -2135228409
Output:
VBoxManage.exe: error: Cannot attach medium 'F:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\CMS_2024_04_29_prod.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later
VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown
VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 785 of file VBoxManageStorageController.cpp

2024-05-21 20:26:57 (700): 
Command: VBoxManage -q showhdinfo "F:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2024_04_29_prod.vdi" 
Exit Code: 0
Output:
UUID:           461abfaf-39ef-4b91-89ba-53cae0787c5e
Parent UUID:    base
State:          created
Type:           multiattach
Location:       F:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\CMS_2024_04_29_prod.vdi
Storage format: VDI
Format variant: dynamic default
Capacity:       20480 MBytes
Size on disk:   3853 MBytes
Encryption:     disabled
Property:       AllocationBlockSize=1048576

2024-05-21 20:26:57 (700): 
Command: VBoxManage -q closemedium disk "F:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\CMS_2024_04_29_prod.vdi" 
Exit Code: 0
Output:

2024-05-21 20:26:57 (700): 
Command: VBoxManage -q showhdinfo "F:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2024_04_29_prod.vdi" 
Exit Code: 0
Output:
UUID:           461abfaf-39ef-4b91-89ba-53cae0787c5e
Parent UUID:    base
State:          created
Type:           normal (base)
Location:       F:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\CMS_2024_04_29_prod.vdi
Storage format: VDI
Format variant: dynamic default
Capacity:       20480 MBytes
Size on disk:   3853 MBytes
Encryption:     disabled
Property:       AllocationBlockSize=1048576

2024-05-21 20:26:58 (700): 
Command: VBoxManage -q storageattach "boinc_1765182ccd0b2ba8" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "F:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2024_04_29_prod.vdi" 
Exit Code: 0
Output:

2024-05-21 20:26:58 (700): 
Command: VBoxManage -q storageattach "boinc_1765182ccd0b2ba8" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none 
Exit Code: 0
Output:

2024-05-21 20:26:58 (700): 
Command: VBoxManage -q storageattach "boinc_1765182ccd0b2ba8" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "F:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2024_04_29_prod.vdi" 
Exit Code: 0
Output:

2024-05-21 20:26:58 (700): 
Command: VBoxManage -q storageattach "boinc_1765182ccd0b2ba8" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2024-05-21 20:26:59 (700): 
Command: VBoxManage -q bandwidthctl "boinc_1765182ccd0b2ba8" add "boinc_1765182ccd0b2ba8_net" --type network --limit 1024G 
Exit Code: 0
Output:

2024-05-21 20:26:59 (700): 
Command: VBoxManage -q modifyvm "boinc_1765182ccd0b2ba8" --natpf1 ",tcp,127.0.0.1,20473,,80" 
Exit Code: 0
Output:

2024-05-21 20:26:59 (700): 
Command: VBoxManage -q list extpacks
Exit Code: 0
Output:
Extension Packs: 1
Pack no. 0:   Oracle VM VirtualBox Extension Pack
Version:        7.0.8
Revision:       156879
Edition:        
Description:    Oracle Cloud Infrastructure integration, Host Webcam, VirtualBox RDP, PXE ROM, Disk Encryption, NVMe, full VM encryption.
VRDE Module:    VBoxVRDP
Crypto Module:  VBoxPuelCrypto
Usable:         true
Why unusable:   

2024-05-21 20:27:00 (700): 
Command: VBoxManage -q modifyvm "boinc_1765182ccd0b2ba8" --vrde on --vrdeextpack default --vrdeauthlibrary default --vrdeauthtype null --vrdeport 20474 
Exit Code: 0
Output:

2024-05-21 20:27:00 (700): 
Command: VBoxManage -q sharedfolder add "boinc_1765182ccd0b2ba8" --name "shared" --hostpath "F:\ProgramData\BOINC\slots\6/shared"
Exit Code: 0
Output:

2024-05-21 20:27:06 (700): 
Command: VBoxManage -q startvm "boinc_1765182ccd0b2ba8" --type headless
Exit Code: -2147467259
Output:
VBoxManage.exe: error: Failed to launch the Remote Desktop Extension server (VERR_GENERAL_FAILURE)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole
Waiting for VM "boinc_1765182ccd0b2ba8" to power on...

2024-05-21 20:27:06 (700): 
Command: VBoxManage -q snapshot "boinc_1765182ccd0b2ba8" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2024-05-21 20:27:06 (700): 
Command: VBoxManage -q bandwidthctl "boinc_1765182ccd0b2ba8" remove "boinc_1765182ccd0b2ba8_net" 
Exit Code: 0
Output:
VBoxManage.exe: error: Bandwidth groups cannot be deleted while the VM is running

2024-05-21 20:27:06 (700): 
Command: VBoxManage -q unregistervm "boinc_1765182ccd0b2ba8" --delete 
Exit Code: -2135228409
Output:
VBoxManage.exe: error: Cannot unregister the machine 'boinc_1765182ccd0b2ba8' while it is locked
VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component MachineWrap, interface IMachine, callee IUnknown
VBoxManage.exe: error: Context: "Unregister(fDeleteAll ? CleanupMode_DetachAllReturnHardDisksAndVMRemovable :CleanupMode_DetachAllReturnHardDisksOnly, ComSafeArrayAsOutParam(aMedia))" at line 236 of file VBoxManageMisc.cpp

2024-05-21 20:27:08 (700): 
Command: VBoxManage -q unregistervm "boinc_1765182ccd0b2ba8" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

2024-05-21 20:27:13 (700): called boinc_finish(-2147467259)

</stderr_txt>
]]>


©2024 CERN