Name | CMS_2360886_1714808334.311841_0 |
Workunit | 222749638 |
Created | 4 May 2024, 7:38:59 UTC |
Sent | 4 May 2024, 8:08:41 UTC |
Report deadline | 4 Jun 2024, 8:08:41 UTC |
Received | 20 May 2024, 6:56:14 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | -2147467259 (0x80004005) Unknown error code |
Computer ID | 10560099 |
Run time | 25 sec |
CPU time | 0 sec |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 13.36 GFLOPS |
Application version | CMS Simulation v70.30 (vbox64_mt_mcore_cms) windows_x86_64 |
Peak working set size | 10.66 MB |
Peak swap size | 6.26 MB |
Peak disk usage | 9.41 KB |
<core_client_version>7.24.1</core_client_version> <![CDATA[ <message> Erreur non sp�cifi�e (0x80004005) - exit code 2147500037 (0x80004005)</message> <stderr_txt> 2024-05-20 08:45:07 (26220): vboxwrapper version 26207 2024-05-20 08:45:07 (26220): BOINC client version: 7.24.1 2024-05-20 08:45:09 (26220): Detected: VirtualBox VboxManage Interface (Version: 7.0.18) 2024-05-20 08:45:09 (26220): Detected: Heartbeat check (file: 'heartbeat' every 1200.000000 seconds) 2024-05-20 08:45:09 (26220): Successfully copied 'init_data.xml' to the shared directory. 2024-05-20 08:45:09 (26220): Create VM. (boinc_f116e5b41fbea494, slot#3) 2024-05-20 08:45:10 (26220): Setting Memory Size for VM. (3688MB) 2024-05-20 08:45:10 (26220): Setting CPU Count for VM. (3) 2024-05-20 08:45:10 (26220): Setting Chipset Options for VM. 2024-05-20 08:45:10 (26220): Setting Graphics Controller Options for VM. 2024-05-20 08:45:11 (26220): Setting Boot Options for VM. 2024-05-20 08:45:11 (26220): Setting Network Configuration for NAT. 2024-05-20 08:45:11 (26220): Enabling VM Network Access. 2024-05-20 08:45:11 (26220): Disabling USB Support for VM. 2024-05-20 08:45:12 (26220): Disabling COM Port Support for VM. 2024-05-20 08:45:12 (26220): Disabling LPT Port Support for VM. 2024-05-20 08:45:12 (26220): Disabling Audio Support for VM. 2024-05-20 08:45:13 (26220): Disabling Clipboard Support for VM. 2024-05-20 08:45:13 (26220): Disabling Drag and Drop Support for VM. 2024-05-20 08:45:13 (26220): Adding storage controller(s) to VM. 2024-05-20 08:45:13 (26220): Adding virtual disk drive to VM. (CMS_2024_04_29_prod.vdi) 2024-05-20 08:45:16 (26220): Adding VirtualBox Guest Additions to VM. 2024-05-20 08:45:16 (26220): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2024-05-20 08:45:16 (26220): forwarding host port 59239 to guest port 80 2024-05-20 08:45:16 (26220): Enabling remote desktop for VM. 2024-05-20 08:45:17 (26220): Enabling shared directory for VM. 2024-05-20 08:45:18 (26220): Starting VM using VBoxManage interface. (boinc_f116e5b41fbea494, slot#3) 2024-05-20 08:45:23 (26220): Error in start VM for VM: -2147467259 Command: VBoxManage -q startvm "boinc_f116e5b41fbea494" --type headless Output: VBoxManage.exe: error: Failed to launch the Remote Desktop Extension server (VERR_GENERAL_FAILURE) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole Waiting for VM "boinc_f116e5b41fbea494" to power on... 2024-05-20 08:45:23 (26220): VM failed to start. 2024-05-20 08:45:23 (26220): Could not start 2024-05-20 08:45:23 (26220): ERROR: VM failed to start 2024-05-20 08:45:23 (26220): Powering off VM. 2024-05-20 08:45:23 (26220): Deregistering VM. (boinc_f116e5b41fbea494, slot#3) 2024-05-20 08:45:23 (26220): Removing network bandwidth throttle group from VM. 2024-05-20 08:45:24 (26220): Removing VM from VirtualBox. Hypervisor System Log: 00:00:08.832711 Saving settings file "F:\ProgramData\BOINC\slots\3\boinc_f116e5b41fbea494\boinc_f116e5b41fbea494.vbox" with version "1.19-windows" 00:00:08.847152 Finished saving settings file "F:\ProgramData\BOINC\slots\3\boinc_f116e5b41fbea494\boinc_f116e5b41fbea494.vbox" 00:00:09.379729 Saving settings file "F:\ProgramData\BOINC\slots\3\boinc_f116e5b41fbea494\boinc_f116e5b41fbea494.vbox" with version "1.19-windows" 00:00:09.394940 Finished saving settings file "F:\ProgramData\BOINC\slots\3\boinc_f116e5b41fbea494\boinc_f116e5b41fbea494.vbox" 00:00:09.708991 Saving settings file "F:\ProgramData\BOINC\slots\3\boinc_f116e5b41fbea494\boinc_f116e5b41fbea494.vbox" with version "1.19-windows" 00:00:09.726769 Finished saving settings file "F:\ProgramData\BOINC\slots\3\boinc_f116e5b41fbea494\boinc_f116e5b41fbea494.vbox" 00:00:09.988498 ERROR [COM]: aRC=VBOX_E_NOT_SUPPORTED (0x80bb0009) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This VM is not encrypted}, preserve=false aResultDetail=0 00:00:09.995498 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.995580 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:10.103089 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:10.444883 Launched VM: 3591712528 pid: 18896 (0x49d0) frontend: headless name: boinc_f116e5b41fbea494 00:00:15.765303 Saving settings file "F:\ProgramData\BOINC\slots\3\boinc_f116e5b41fbea494\boinc_f116e5b41fbea494.vbox" with version "1.19-windows" 00:00:15.781734 Finished saving settings file "F:\ProgramData\BOINC\slots\3\boinc_f116e5b41fbea494\boinc_f116e5b41fbea494.vbox" 00:00:15.890000 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:16.238679 ERROR [COM]: aRC=VBOX_E_INVALID_OBJECT_STATE (0x80bb0007) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={Cannot unregister the machine 'boinc_f116e5b41fbea494' while it is locked}, preserve=false aResultDetail=0 00:00:17.533667 Saving settings file "C:\Users\ZEUS\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:17.548115 Finished saving settings file "C:\Users\ZEUS\.VirtualBox\VirtualBox.xml" 00:00:17.548260 Saving settings file "C:\Users\ZEUS\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:17.559969 Finished saving settings file "C:\Users\ZEUS\.VirtualBox\VirtualBox.xml" 00:00:17.561165 DeleteVM Saving settings file "C:\Users\ZEUS\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:17.573479 DeleteVM Finished saving settings file "C:\Users\ZEUS\.VirtualBox\VirtualBox.xml" 00:00:22.582733 main VirtualBox: object deletion starts 00:00:22.582804 main ERROR [COM]: aRC=VBOX_E_OBJECT_IN_USE (0x80bb000c) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Medium 'F:\VHDs\LECO\LECO CornerStone\LECO CornerStone.vdi' cannot be closed because it is still attached to 1 virtual machines}, preserve=false aResultDetail=0 00:00:22.583474 main ERROR [COM]: aRC=VBOX_E_OBJECT_IN_USE (0x80bb000c) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Medium 'F:\VHDs\LECO\Virtual PC XP\Windows XPM.vhd' cannot be closed because it is still attached to 1 virtual machines}, preserve=false aResultDetail=0 00:00:22.583928 main ERROR [COM]: aRC=VBOX_E_OBJECT_IN_USE (0x80bb000c) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Medium '\\nas-hermes\VHDs\Photos - Pro\Photos - Pro.vdi' cannot be closed because it is still attached to 1 virtual machines}, preserve=false aResultDetail=0 00:00:22.584781 main ERROR [COM]: aRC=VBOX_E_OBJECT_IN_USE (0x80bb000c) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Medium 'I:\VirtualBox VMs\Web\Windows 7 Professionnel (WordPress)\Windows 7 Professionnel (WordPress) 2.vdi' cannot be closed because it is still attached to 1 virtual machines}, preserve=false aResultDetail=0 00:00:22.585804 main ERROR [COM]: aRC=VBOX_E_OBJECT_IN_USE (0x80bb000c) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Medium '\\nas-hermes\VHDs\Linux Mint Mate\Linux Mint Mate.vdi' cannot be closed because it is still attached to 1 virtual machines}, preserve=false aResultDetail=0 00:00:22.586345 main ERROR [COM]: aRC=VBOX_E_OBJECT_IN_USE (0x80bb000c) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Medium '\\nas-hermes\VHDs\Photos - Pro V2.vdi' cannot be closed because it is still attached to 1 virtual machines}, preserve=false aResultDetail=0 00:00:22.587119 main ERROR [COM]: aRC=VBOX_E_OBJECT_IN_USE (0x80bb000c) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Medium 'I:\VirtualBox VMs\Windows 7\Windows 7 Intégrale x64\Windows 7 Intégrale x64.vdi' cannot be closed because it is still attached to 1 virtual machines}, preserve=false aResultDetail=0 00:00:22.587552 main ERROR [COM]: aRC=VBOX_E_OBJECT_IN_USE (0x80bb000c) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Medium 'I:\VirtualBox VMs\Windows 2012 R2\Windows 2012 R2.vdi' cannot be closed because it is still attached to 1 virtual machines}, preserve=false aResultDetail=0 00:00:22.587972 main ERROR [COM]: aRC=VBOX_E_OBJECT_IN_USE (0x80bb000c) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Medium 'I:\VirtualBox VMs\Windows 10 Pro\Windows 10 Pro.vdi' cannot be closed because it is still attached to 1 virtual machines}, preserve=false aResultDetail=0 00:00:22.588398 main ERROR [COM]: aRC=VBOX_E_OBJECT_IN_USE (0x80bb000c) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Medium 'I:\VirtualBox VMs\Windows 7 Pro x64\Windows 7 Pro x64-disk001.vmdk' cannot be closed because it is still attached to 1 virtual machines}, preserve=false aResultDetail=0 00:00:22.589022 main ERROR [COM]: aRC=VBOX_E_OBJECT_IN_USE (0x80bb000c) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Medium 'I:\VirtualBox VMs\W7Px64\En Cours de TEST\Windows 7 Pro x64 - TEST\Windows 7 Pro x64.vdi' cannot be closed because it is still attached to 1 virtual machines}, preserve=false aResultDetail=0 00:00:22.589442 main ERROR [COM]: aRC=VBOX_E_OBJECT_IN_USE (0x80bb000c) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Medium 'I:\VirtualBox VMs\Windows 10 WS\Windows 10 Pro WorkStation\Windows 10 Pro WorkStation.vdi' cannot be closed because it is still attached to 1 virtual machines}, preserve=false aResultDetail=0 00:00:22.590390 main ERROR [COM]: aRC=VBOX_E_OBJECT_IN_USE (0x80bb000c) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Medium 'I:\VirtualBox VMs\Windows 2019\Windows 2019 Serveur\Windows 2019 Serveur.vdi' cannot be closed because it is still attached to 1 virtual machines}, preserve=false aResultDetail=0 00:00:22.592104 main HostDnsMonitor: shutting down ... 00:00:22.592142 main HostDnsMonitor: shut down 00:00:22.594938 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:22.595532 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: --graphicscontroller VBoxVGA Exit Code: 0 Output: 2024-05-20 08:45:11 (26220): Command: VBoxManage -q modifyvm "boinc_f116e5b41fbea494" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2024-05-20 08:45:11 (26220): Command: VBoxManage -q modifyvm "boinc_f116e5b41fbea494" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2024-05-20 08:45:11 (26220): Command: VBoxManage -q modifyvm "boinc_f116e5b41fbea494" --cableconnected1 on Exit Code: 0 Output: 2024-05-20 08:45:12 (26220): Command: VBoxManage -q modifyvm "boinc_f116e5b41fbea494" --usb off Exit Code: 0 Output: 2024-05-20 08:45:12 (26220): Command: VBoxManage -q modifyvm "boinc_f116e5b41fbea494" --uart1 off --uart2 off Exit Code: 0 Output: 2024-05-20 08:45:12 (26220): Command: VBoxManage -q modifyvm "boinc_f116e5b41fbea494" --lpt1 off --lpt2 off Exit Code: 0 Output: 2024-05-20 08:45:13 (26220): Command: VBoxManage -q modifyvm "boinc_f116e5b41fbea494" --audio-enabled off Exit Code: 0 Output: 2024-05-20 08:45:13 (26220): Command: VBoxManage -q modifyvm "boinc_f116e5b41fbea494" --clipboard disabled Exit Code: 0 Output: 2024-05-20 08:45:13 (26220): Command: VBoxManage -q modifyvm "boinc_f116e5b41fbea494" --draganddrop disabled Exit Code: 0 Output: 2024-05-20 08:45:13 (26220): Command: VBoxManage -q storagectl "boinc_f116e5b41fbea494" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2024-05-20 08:45:14 (26220): Command: VBoxManage -q showhdinfo "F:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2024_04_29_prod.vdi" Exit Code: 0 Output: UUID: 461abfaf-39ef-4b91-89ba-53cae0787c5e Parent UUID: base State: created Type: multiattach Location: F:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\CMS_2024_04_29_prod.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 3853 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2024-05-20 08:45:14 (26220): Command: VBoxManage -q storageattach "boinc_f116e5b41fbea494" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "F:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2024_04_29_prod.vdi" Exit Code: -2135228409 Output: VBoxManage.exe: error: Cannot attach medium 'F:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\CMS_2024_04_29_prod.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 785 of file VBoxManageStorageController.cpp 2024-05-20 08:45:14 (26220): Command: VBoxManage -q showhdinfo "F:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2024_04_29_prod.vdi" Exit Code: 0 Output: UUID: 461abfaf-39ef-4b91-89ba-53cae0787c5e Parent UUID: base State: created Type: multiattach Location: F:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\CMS_2024_04_29_prod.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 3853 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2024-05-20 08:45:14 (26220): Command: VBoxManage -q closemedium disk "F:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\CMS_2024_04_29_prod.vdi" Exit Code: 0 Output: 2024-05-20 08:45:15 (26220): Command: VBoxManage -q showhdinfo "F:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2024_04_29_prod.vdi" Exit Code: 0 Output: UUID: 461abfaf-39ef-4b91-89ba-53cae0787c5e Parent UUID: base State: created Type: normal (base) Location: F:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\CMS_2024_04_29_prod.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 3853 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2024-05-20 08:45:15 (26220): Command: VBoxManage -q storageattach "boinc_f116e5b41fbea494" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "F:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2024_04_29_prod.vdi" Exit Code: 0 Output: 2024-05-20 08:45:15 (26220): Command: VBoxManage -q storageattach "boinc_f116e5b41fbea494" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none Exit Code: 0 Output: 2024-05-20 08:45:16 (26220): Command: VBoxManage -q storageattach "boinc_f116e5b41fbea494" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "F:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2024_04_29_prod.vdi" Exit Code: 0 Output: 2024-05-20 08:45:16 (26220): Command: VBoxManage -q storageattach "boinc_f116e5b41fbea494" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2024-05-20 08:45:16 (26220): Command: VBoxManage -q bandwidthctl "boinc_f116e5b41fbea494" add "boinc_f116e5b41fbea494_net" --type network --limit 1024G Exit Code: 0 Output: 2024-05-20 08:45:16 (26220): Command: VBoxManage -q modifyvm "boinc_f116e5b41fbea494" --natpf1 ",tcp,127.0.0.1,59239,,80" Exit Code: 0 Output: 2024-05-20 08:45:17 (26220): Command: VBoxManage -q list extpacks Exit Code: 0 Output: Extension Packs: 1 Pack no. 0: Oracle VM VirtualBox Extension Pack Version: 7.0.8 Revision: 156879 Edition: Description: Oracle Cloud Infrastructure integration, Host Webcam, VirtualBox RDP, PXE ROM, Disk Encryption, NVMe, full VM encryption. VRDE Module: VBoxVRDP Crypto Module: VBoxPuelCrypto Usable: true Why unusable: 2024-05-20 08:45:17 (26220): Command: VBoxManage -q modifyvm "boinc_f116e5b41fbea494" --vrde on --vrdeextpack default --vrdeauthlibrary default --vrdeauthtype null --vrdeport 59240 Exit Code: 0 Output: 2024-05-20 08:45:17 (26220): Command: VBoxManage -q sharedfolder add "boinc_f116e5b41fbea494" --name "shared" --hostpath "F:\ProgramData\BOINC\slots\3/shared" Exit Code: 0 Output: 2024-05-20 08:45:23 (26220): Command: VBoxManage -q startvm "boinc_f116e5b41fbea494" --type headless Exit Code: -2147467259 Output: VBoxManage.exe: error: Failed to launch the Remote Desktop Extension server (VERR_GENERAL_FAILURE) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole Waiting for VM "boinc_f116e5b41fbea494" to power on... 2024-05-20 08:45:23 (26220): Command: VBoxManage -q snapshot "boinc_f116e5b41fbea494" list Exit Code: -108 Output: This machine does not have any snapshots 2024-05-20 08:45:24 (26220): Command: VBoxManage -q bandwidthctl "boinc_f116e5b41fbea494" remove "boinc_f116e5b41fbea494_net" Exit Code: 0 Output: VBoxManage.exe: error: Bandwidth groups cannot be deleted while the VM is running 2024-05-20 08:45:24 (26220): Command: VBoxManage -q unregistervm "boinc_f116e5b41fbea494" --delete Exit Code: -2135228409 Output: VBoxManage.exe: error: Cannot unregister the machine 'boinc_f116e5b41fbea494' while it is locked VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component MachineWrap, interface IMachine, callee IUnknown VBoxManage.exe: error: Context: "Unregister(fDeleteAll ? CleanupMode_DetachAllReturnHardDisksAndVMRemovable :CleanupMode_DetachAllReturnHardDisksOnly, ComSafeArrayAsOutParam(aMedia))" at line 236 of file VBoxManageMisc.cpp 2024-05-20 08:45:25 (26220): Command: VBoxManage -q unregistervm "boinc_f116e5b41fbea494" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 2024-05-20 08:45:30 (26220): called boinc_finish(-2147467259) </stderr_txt> ]]>
©2024 CERN