Name | CMS_3575512_1752372903.319161_0 |
Workunit | 233599411 |
Created | 13 Jul 2025, 2:15:04 UTC |
Sent | 13 Jul 2025, 3:55:57 UTC |
Report deadline | 13 Aug 2025, 3:55:57 UTC |
Received | 13 Jul 2025, 4:56:24 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | 1 (0x00000001) Unknown error code |
Computer ID | 10774469 |
Run time | 19 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 17.74 GFLOPS |
Application version | CMS Simulation v70.91 (vbox64_mt_mcore_cms) windows_x86_64 |
Peak working set size | 6.78 MB |
Peak swap size | 1.93 MB |
Peak disk usage | 0.77 MB |
<core_client_version>7.22.2</core_client_version> <![CDATA[ <message> - exit code 1 (0x1)</message> <stderr_txt> 2025-07-13 13:54:47 (13872): vboxwrapper version 26210 2025-07-13 13:54:47 (13872): BOINC client version: 7.22.2 2025-07-13 13:54:48 (13872): Detected: VirtualBox VboxManage Interface (Version: 7.1.6) 2025-07-13 13:54:48 (13872): Detected: Heartbeat check (file: 'heartbeat' every 1200.000000 seconds) 2025-07-13 13:54:48 (13872): Successfully copied 'init_data.xml' to the shared directory. 2025-07-13 13:54:49 (13872): Create VM. (boinc_7f8402842347b403, slot#1) 2025-07-13 13:54:49 (13872): Setting Memory Size for VM. (4584MB) 2025-07-13 13:54:49 (13872): Setting CPU Count for VM. (4) 2025-07-13 13:54:50 (13872): Setting Chipset Options for VM. 2025-07-13 13:54:50 (13872): Setting Graphics Controller Options for VM. (Driver: VBoxVGA, 16MB) 2025-07-13 13:54:50 (13872): Setting Boot Options for VM. 2025-07-13 13:54:51 (13872): Setting Network Configuration for NAT. (Driver: virtio) 2025-07-13 13:54:51 (13872): Enabling VM Network Access. 2025-07-13 13:54:51 (13872): Disabling USB Support for VM. 2025-07-13 13:54:52 (13872): Disabling COM Port Support for VM. 2025-07-13 13:54:52 (13872): Disabling LPT Port Support for VM. 2025-07-13 13:54:52 (13872): Disabling Audio Support for VM. 2025-07-13 13:54:52 (13872): Disabling Clipboard Support for VM. 2025-07-13 13:54:53 (13872): Disabling Drag and Drop Support for VM. 2025-07-13 13:54:53 (13872): Adding storage controller(s) to VM. 2025-07-13 13:54:53 (13872): Adding virtual disk drive to VM. (CMS_2025_04_08_prod.vdi) 2025-07-13 13:54:55 (13872): Adding VirtualBox Guest Additions to VM. 2025-07-13 13:54:56 (13872): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2025-07-13 13:54:56 (13872): forwarding host port 50457 to guest port 80 2025-07-13 13:54:56 (13872): Enabling remote desktop for VM. 2025-07-13 13:54:57 (13872): Enabling shared directory for VM. 2025-07-13 13:54:57 (13872): Starting VM using VBoxManage interface. (boinc_7f8402842347b403, slot#1) 2025-07-13 13:54:59 (13872): Error in start VM for VM: 1 Command: VBoxManage -q startvm "boinc_7f8402842347b403" --type headless Output: VBoxManage.exe: error: The virtual machine 'boinc_7f8402842347b403' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\1\boinc_7f8402842347b403\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_7f8402842347b403" to power on... 2025-07-13 13:54:59 (13872): VM failed to start. 2025-07-13 13:54:59 (13872): Could not start 2025-07-13 13:54:59 (13872): ERROR: VM failed to start 2025-07-13 13:54:59 (13872): Powering off VM. 2025-07-13 13:54:59 (13872): Deregistering VM. (boinc_7f8402842347b403, slot#1) 2025-07-13 13:54:59 (13872): Removing network bandwidth throttle group from VM. 2025-07-13 13:54:59 (13872): Removing VM from VirtualBox. Hypervisor System Log: 00:00:07.793936 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_7f8402842347b403\boinc_7f8402842347b403.vbox" 00:00:07.794142 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.796169 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_7f8402842347b403\boinc_7f8402842347b403.vbox" with version "1.19-windows" 00:00:07.840666 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_7f8402842347b403\boinc_7f8402842347b403.vbox" 00:00:07.841234 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_7f8402842347b403\boinc_7f8402842347b403.vbox" with version "1.19-windows" 00:00:07.901107 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_7f8402842347b403\boinc_7f8402842347b403.vbox" 00:00:07.980109 Platform architecture set to 'x86' 00:00:07.982243 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.983952 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.984181 Saving settings file "C:\Users\miyan\.VirtualBox\VirtualBox.xml" with version "1.14-windows" 00:00:08.043762 Finished saving settings file "C:\Users\miyan\.VirtualBox\VirtualBox.xml" 00:00:08.044185 Saving settings file "C:\Users\miyan\.VirtualBox\VirtualBox.xml" with version "1.14-windows" 00:00:08.118569 Finished saving settings file "C:\Users\miyan\.VirtualBox\VirtualBox.xml" 00:00:08.119031 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_7f8402842347b403\boinc_7f8402842347b403.vbox" with version "1.19-windows" 00:00:08.161253 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_7f8402842347b403\boinc_7f8402842347b403.vbox" 00:00:08.245951 Platform architecture set to 'x86' 00:00:08.247689 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_7f8402842347b403\boinc_7f8402842347b403.vbox" with version "1.19-windows" 00:00:08.330962 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_7f8402842347b403\boinc_7f8402842347b403.vbox" 00:00:08.512959 Platform architecture set to 'x86' 00:00:08.515666 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_7f8402842347b403\boinc_7f8402842347b403.vbox" with version "1.19-windows" 00:00:08.582295 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_7f8402842347b403\boinc_7f8402842347b403.vbox" 00:00:09.042525 Platform architecture set to 'x86' 00:00:09.044679 VRDE: Generating certificate files 'C:\ProgramData\BOINC\slots\1\boinc_7f8402842347b403\VRDEAutoGeneratedCert.pem' and 'C:\ProgramData\BOINC\slots\1\boinc_7f8402842347b403\VRDEAutoGeneratedPrivateKey.pem'... 00:00:09.069865 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_7f8402842347b403\boinc_7f8402842347b403.vbox" with version "1.19-windows" 00:00:09.107268 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_7f8402842347b403\boinc_7f8402842347b403.vbox" 00:00:09.309300 Platform architecture set to 'x86' 00:00:09.310820 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_7f8402842347b403\boinc_7f8402842347b403.vbox" with version "1.19-windows" 00:00:09.394157 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_7f8402842347b403\boinc_7f8402842347b403.vbox" 00:00:09.573203 Platform architecture set to 'x86' 00:00:09.575318 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={d644ad1e-c501-4fc7-9ab6-aa6d763bc540} aComponent={VirtualBoxWrap} aText={Ńo extension pack providing a cryptographic support module could be found}, preserve=false aResultDetail=0 00:00:09.581111 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.581229 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.586282 WARNING [COM]: aRC=E_FAIL (0x80004005) aIID={d5dcece0-b202-4416-a138-03502784cc07} aComponent={HostWrap} aText={Could not load the Host USB Proxy Service (VERR_FILE_NOT_FOUND). The service might not be installed on the host computer}, preserve=true aResultDetail=0 00:00:09.586370 WARNING [COM]: aRC=E_FAIL (0x80004005) aIID={d5dcece0-b202-4416-a138-03502784cc07} aComponent={HostWrap} aText={Could not load the Host USB Proxy Service (VERR_FILE_NOT_FOUND). The service might not be installed on the host computer}, preserve=true aResultDetail=0 00:00:09.588537 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={bea3ef5c-de2f-4b74-aa3a-15d6249371a0} aComponent={RecordingSettingsWrap} aText={Recording not started}, preserve=false aResultDetail=0 00:00:09.589355 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:09.848997 Launched VM: 886722688 pid: 2096 (0x830) frontend: headless name: boinc_7f8402842347b403 00:00:11.272406 Watcher ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={MachineWrap} aText={The virtual machine 'boinc_7f8402842347b403' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\1\boinc_7f8402842347b403\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0 00:00:11.353295 Platform architecture set to 'x86' 00:00:11.354394 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:11.425471 Platform architecture set to 'x86' 00:00:11.427269 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_7f8402842347b403\boinc_7f8402842347b403.vbox" with version "1.19-windows" 00:00:11.582077 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_7f8402842347b403\boinc_7f8402842347b403.vbox" 00:00:11.802566 Saving settings file "C:\Users\miyan\.VirtualBox\VirtualBox.xml" with version "1.14-windows" 00:00:11.857951 Finished saving settings file "C:\Users\miyan\.VirtualBox\VirtualBox.xml" 00:00:11.858228 Saving settings file "C:\Users\miyan\.VirtualBox\VirtualBox.xml" with version "1.14-windows" 00:00:11.957155 Finished saving settings file "C:\Users\miyan\.VirtualBox\VirtualBox.xml" 00:00:11.958327 DeleteVM Saving settings file "C:\Users\miyan\.VirtualBox\VirtualBox.xml" with version "1.14-windows" 00:00:12.037871 DeleteVM Finished saving settings file "C:\Users\miyan\.VirtualBox\VirtualBox.xml" 00:00:17.032496 main VirtualBox: object deletion starts 00:00:17.034385 main HostDnsMonitor: shutting down ... 00:00:17.034426 main HostDnsMonitor: shut down 00:00:17.035779 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d644ad1e-c501-4fc7-9ab6-aa6d763bc540} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:17.036286 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: recording_started="off" recording_enabled="off" recording_screens=1 rec_screen0 rec_screen_enabled="on" rec_screen_id=0 rec_screen_video_enabled="on" rec_screen_audio_enabled="off" rec_screen_dest="File" rec_screen_dest_filename="C:\\ProgramData\\BOINC\\slots\\1\\boinc_7f8402842347b403\\boinc_7f8402842347b403-screen0.webm" rec_screen_opts="vc_enabled=true,ac_enabled=false,ac_profile=med" rec_screen_video_res_xy="1024x768" rec_screen_video_rate_kbps=512 rec_screen_video_fps=25 description="CMS_3575512_1752372903.319161_0" GuestMemoryBalloon=0 2025-07-13 13:54:51 (13872): Command: VBoxManage -q modifyvm "boinc_7f8402842347b403" --nic1 nat --nic-type1 "virtio" --cable-connected1 off --nat-dns-proxy1 on Exit Code: 0 Output: 2025-07-13 13:54:51 (13872): Command: VBoxManage -q modifyvm "boinc_7f8402842347b403" --cable-connected1 on Exit Code: 0 Output: 2025-07-13 13:54:52 (13872): Command: VBoxManage -q modifyvm "boinc_7f8402842347b403" --usb off Exit Code: 0 Output: 2025-07-13 13:54:52 (13872): Command: VBoxManage -q modifyvm "boinc_7f8402842347b403" --uart1 off --uart2 off Exit Code: 0 Output: 2025-07-13 13:54:52 (13872): Command: VBoxManage -q modifyvm "boinc_7f8402842347b403" --lpt1 off --lpt2 off Exit Code: 0 Output: 2025-07-13 13:54:52 (13872): Command: VBoxManage -q modifyvm "boinc_7f8402842347b403" --audio-enabled off Exit Code: 0 Output: 2025-07-13 13:54:53 (13872): Command: VBoxManage -q modifyvm "boinc_7f8402842347b403" --clipboard disabled Exit Code: 0 Output: 2025-07-13 13:54:53 (13872): Command: VBoxManage -q modifyvm "boinc_7f8402842347b403" --draganddrop disabled Exit Code: 0 Output: 2025-07-13 13:54:53 (13872): Command: VBoxManage -q storagectl "boinc_7f8402842347b403" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2025-07-13 13:54:53 (13872): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2025_04_08_prod.vdi" Exit Code: 0 Output: UUID: fa49c4e2-ad29-47a5-b96a-3c89ce80d84c Parent UUID: base State: created Type: multiattach Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\CMS_2025_04_08_prod.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 3853 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-07-13 13:54:54 (13872): Command: VBoxManage -q storageattach "boinc_7f8402842347b403" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2025_04_08_prod.vdi" Exit Code: -2135228409 Output: VBoxManage.exe: error: Cannot attach medium 'C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\CMS_2025_04_08_prod.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 786 of file VBoxManageStorageController.cpp 2025-07-13 13:54:54 (13872): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2025_04_08_prod.vdi" Exit Code: 0 Output: UUID: fa49c4e2-ad29-47a5-b96a-3c89ce80d84c Parent UUID: base State: created Type: multiattach Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\CMS_2025_04_08_prod.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 3853 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-07-13 13:54:54 (13872): Command: VBoxManage -q closemedium disk "C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\CMS_2025_04_08_prod.vdi" Exit Code: 0 Output: 2025-07-13 13:54:55 (13872): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2025_04_08_prod.vdi" Exit Code: 0 Output: UUID: fa49c4e2-ad29-47a5-b96a-3c89ce80d84c Parent UUID: base State: created Type: normal (base) Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\CMS_2025_04_08_prod.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 3853 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-07-13 13:54:55 (13872): Command: VBoxManage -q storageattach "boinc_7f8402842347b403" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2025_04_08_prod.vdi" Exit Code: 0 Output: 2025-07-13 13:54:55 (13872): Command: VBoxManage -q storageattach "boinc_7f8402842347b403" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none Exit Code: 0 Output: 2025-07-13 13:54:55 (13872): Command: VBoxManage -q storageattach "boinc_7f8402842347b403" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2025_04_08_prod.vdi" Exit Code: 0 Output: 2025-07-13 13:54:56 (13872): Command: VBoxManage -q storageattach "boinc_7f8402842347b403" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2025-07-13 13:54:56 (13872): Command: VBoxManage -q bandwidthctl "boinc_7f8402842347b403" add "boinc_7f8402842347b403_net" --type network --limit 1024G Exit Code: 0 Output: 2025-07-13 13:54:56 (13872): Command: VBoxManage -q modifyvm "boinc_7f8402842347b403" --natpf1 ",tcp,127.0.0.1,50457,,80" Exit Code: 0 Output: 2025-07-13 13:54:56 (13872): Command: VBoxManage -q list extpacks Exit Code: 0 Output: Extension Packs: 1 Pack no. 0: Oracle VM VirtualBox Extension Pack Version: 7.0.18 Revision: 162988 Edition: Description: Oracle Cloud Infrastructure integration, Host Webcam, VirtualBox RDP, PXE ROM, Disk Encryption, NVMe, full VM encryption. VRDE Module: VBoxVRDP Crypto Module: VBoxPuelCrypto Usable: false Why unusable: VBoxExtPackRegister returned VERR_VERSION_MISMATCH, pReg=0000000000000000 ErrInfo='VirtualBox version mismatch - expected 7.0 got 7.1' 2025-07-13 13:54:57 (13872): Command: VBoxManage -q modifyvm "boinc_7f8402842347b403" --vrde on --vrdeextpack default --vrdeauthlibrary default --vrdeauthtype null --vrdeport 50459 --vrde-property "Security/Method=RDP" Exit Code: 0 Output: 2025-07-13 13:54:57 (13872): Command: VBoxManage -q sharedfolder add "boinc_7f8402842347b403" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\1/shared" Exit Code: 0 Output: 2025-07-13 13:54:59 (13872): Command: VBoxManage -q startvm "boinc_7f8402842347b403" --type headless Exit Code: 1 Output: VBoxManage.exe: error: The virtual machine 'boinc_7f8402842347b403' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\1\boinc_7f8402842347b403\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_7f8402842347b403" to power on... 2025-07-13 13:54:59 (13872): Command: VBoxManage -q snapshot "boinc_7f8402842347b403" list Exit Code: -108 Output: This machine does not have any snapshots 2025-07-13 13:54:59 (13872): Command: VBoxManage -q bandwidthctl "boinc_7f8402842347b403" remove "boinc_7f8402842347b403_net" Exit Code: 0 Output: 2025-07-13 13:55:00 (13872): Command: VBoxManage -q unregistervm "boinc_7f8402842347b403" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 2025-07-13 13:55:05 (13872): called boinc_finish(1) </stderr_txt> ]]>
©2025 CERN