Name | CMS_837297_1740614310.552412_0 |
Workunit | 230576882 |
Created | 26 Feb 2025, 23:58:31 UTC |
Sent | 27 Feb 2025, 0:13:50 UTC |
Report deadline | 30 Mar 2025, 0:13:50 UTC |
Received | 27 Feb 2025, 0:18:32 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | -2147467259 (0x80004005) Unknown error code |
Computer ID | 10849134 |
Run time | 5 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 16.95 GFLOPS |
Application version | CMS Simulation v70.60 (vbox64_mt_mcore_cms) windows_x86_64 |
Peak working set size | 6.63 MB |
Peak swap size | 1.91 MB |
Peak disk usage | 0.74 MB |
<core_client_version>7.24.1</core_client_version> <![CDATA[ <message> Error no especificado (0x80004005) - exit code 2147500037 (0x80004005)</message> <stderr_txt> 2025-02-26 18:16:30 (18104): vboxwrapper version 26208 2025-02-26 18:16:30 (18104): BOINC client version: 7.24.1 2025-02-26 18:16:31 (18104): Detected: VirtualBox VboxManage Interface (Version: 7.1.4) 2025-02-26 18:16:31 (18104): Detected: Heartbeat check (file: 'heartbeat' every 1200.000000 seconds) 2025-02-26 18:16:31 (18104): Successfully copied 'init_data.xml' to the shared directory. 2025-02-26 18:16:31 (18104): Create VM. (boinc_3e235e9f3bdf0732, slot#2) 2025-02-26 18:16:32 (18104): Setting Memory Size for VM. (4584MB) 2025-02-26 18:16:32 (18104): Setting CPU Count for VM. (4) 2025-02-26 18:16:32 (18104): Setting Chipset Options for VM. 2025-02-26 18:16:33 (18104): Setting Graphics Controller Options for VM. 2025-02-26 18:16:33 (18104): Setting Boot Options for VM. 2025-02-26 18:16:33 (18104): Setting Network Configuration for NAT. 2025-02-26 18:16:34 (18104): Enabling VM Network Access. 2025-02-26 18:16:34 (18104): Disabling USB Support for VM. 2025-02-26 18:16:34 (18104): Disabling COM Port Support for VM. 2025-02-26 18:16:34 (18104): Disabling LPT Port Support for VM. 2025-02-26 18:16:35 (18104): Disabling Audio Support for VM. 2025-02-26 18:16:35 (18104): Disabling Clipboard Support for VM. 2025-02-26 18:16:35 (18104): Disabling Drag and Drop Support for VM. 2025-02-26 18:16:35 (18104): Adding storage controller(s) to VM. 2025-02-26 18:16:36 (18104): Adding virtual disk drive to VM. (CMS_2025_01_16_prod.vdi) 2025-02-26 18:16:38 (18104): Adding VirtualBox Guest Additions to VM. 2025-02-26 18:16:38 (18104): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2025-02-26 18:16:38 (18104): forwarding host port 53261 to guest port 80 2025-02-26 18:16:39 (18104): Enabling remote desktop for VM. 2025-02-26 18:16:39 (18104): Required extension pack not installed, remote desktop not enabled. 2025-02-26 18:16:39 (18104): Enabling shared directory for VM. 2025-02-26 18:16:40 (18104): Starting VM using VBoxManage interface. (boinc_3e235e9f3bdf0732, slot#2) 2025-02-26 18:16:45 (18104): Error in start VM for VM: -2147467259 Command: VBoxManage -q startvm "boinc_3e235e9f3bdf0732" --type headless Output: VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole Waiting for VM "boinc_3e235e9f3bdf0732" to power on... 2025-02-26 18:16:45 (18104): VM failed to start. 2025-02-26 18:16:45 (18104): Could not start 2025-02-26 18:16:45 (18104): ERROR: VM failed to start 2025-02-26 18:16:45 (18104): Powering off VM. 2025-02-26 18:16:45 (18104): Deregistering VM. (boinc_3e235e9f3bdf0732, slot#2) 2025-02-26 18:16:45 (18104): Removing network bandwidth throttle group from VM. 2025-02-26 18:16:45 (18104): Removing VM from VirtualBox. Hypervisor System Log: 00:00:06.976653 Saving settings file "C:\Users\MARTHA\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:07.013952 Finished saving settings file "C:\Users\MARTHA\.VirtualBox\VirtualBox.xml" 00:00:07.015973 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_3e235e9f3bdf0732\boinc_3e235e9f3bdf0732.vbox" with version "1.19-windows" 00:00:07.049700 Finished saving settings file "C:\ProgramData\BOINC\slots\2\boinc_3e235e9f3bdf0732\boinc_3e235e9f3bdf0732.vbox" 00:00:07.260813 Platform architecture set to 'x86' 00:00:07.263635 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_3e235e9f3bdf0732\boinc_3e235e9f3bdf0732.vbox" with version "1.19-windows" 00:00:07.289646 Finished saving settings file "C:\ProgramData\BOINC\slots\2\boinc_3e235e9f3bdf0732\boinc_3e235e9f3bdf0732.vbox" 00:00:07.552007 Platform architecture set to 'x86' 00:00:07.554292 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.555006 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_3e235e9f3bdf0732\boinc_3e235e9f3bdf0732.vbox" with version "1.19-windows" 00:00:07.581442 Finished saving settings file "C:\ProgramData\BOINC\slots\2\boinc_3e235e9f3bdf0732\boinc_3e235e9f3bdf0732.vbox" 00:00:07.581644 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.583958 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_3e235e9f3bdf0732\boinc_3e235e9f3bdf0732.vbox" with version "1.19-windows" 00:00:07.623437 Finished saving settings file "C:\ProgramData\BOINC\slots\2\boinc_3e235e9f3bdf0732\boinc_3e235e9f3bdf0732.vbox" 00:00:07.625253 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_3e235e9f3bdf0732\boinc_3e235e9f3bdf0732.vbox" with version "1.19-windows" 00:00:07.649819 Finished saving settings file "C:\ProgramData\BOINC\slots\2\boinc_3e235e9f3bdf0732\boinc_3e235e9f3bdf0732.vbox" 00:00:07.856486 Platform architecture set to 'x86' 00:00:07.859068 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.861349 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.861539 Saving settings file "C:\Users\MARTHA\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:07.884420 Finished saving settings file "C:\Users\MARTHA\.VirtualBox\VirtualBox.xml" 00:00:07.884695 Saving settings file "C:\Users\MARTHA\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:07.902603 Finished saving settings file "C:\Users\MARTHA\.VirtualBox\VirtualBox.xml" 00:00:07.903093 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_3e235e9f3bdf0732\boinc_3e235e9f3bdf0732.vbox" with version "1.19-windows" 00:00:07.926165 Finished saving settings file "C:\ProgramData\BOINC\slots\2\boinc_3e235e9f3bdf0732\boinc_3e235e9f3bdf0732.vbox" 00:00:08.127832 Platform architecture set to 'x86' 00:00:08.129961 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_3e235e9f3bdf0732\boinc_3e235e9f3bdf0732.vbox" with version "1.19-windows" 00:00:08.170295 Finished saving settings file "C:\ProgramData\BOINC\slots\2\boinc_3e235e9f3bdf0732\boinc_3e235e9f3bdf0732.vbox" 00:00:08.433112 Platform architecture set to 'x86' 00:00:08.436011 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_3e235e9f3bdf0732\boinc_3e235e9f3bdf0732.vbox" with version "1.19-windows" 00:00:08.460706 Finished saving settings file "C:\ProgramData\BOINC\slots\2\boinc_3e235e9f3bdf0732\boinc_3e235e9f3bdf0732.vbox" 00:00:09.043097 Platform architecture set to 'x86' 00:00:09.044901 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_3e235e9f3bdf0732\boinc_3e235e9f3bdf0732.vbox" with version "1.19-windows" 00:00:09.061991 Finished saving settings file "C:\ProgramData\BOINC\slots\2\boinc_3e235e9f3bdf0732\boinc_3e235e9f3bdf0732.vbox" 00:00:09.266115 Platform architecture set to 'x86' 00:00:09.268315 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={d644ad1e-c501-4fc7-9ab6-aa6d763bc540} aComponent={VirtualBoxWrap} aText={Ńo extension pack providing a cryptographic support module could be found}, preserve=false aResultDetail=0 00:00:09.276399 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.276490 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.285614 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={bea3ef5c-de2f-4b74-aa3a-15d6249371a0} aComponent={RecordingSettingsWrap} aText={Recording not started}, preserve=false aResultDetail=0 00:00:09.286966 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:09.574457 Launched VM: 841237312 pid: 30360 (0x7698) frontend: headless name: boinc_3e235e9f3bdf0732 00:00:13.544549 Platform architecture set to 'x86' 00:00:14.406940 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_3e235e9f3bdf0732\boinc_3e235e9f3bdf0732.vbox" with version "1.19-windows" 00:00:14.440509 Finished saving settings file "C:\ProgramData\BOINC\slots\2\boinc_3e235e9f3bdf0732\boinc_3e235e9f3bdf0732.vbox" 00:00:14.583691 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={e36a5081-a82a-40bd-9e4e-42a44d6ce50f} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:14.964197 Saving settings file "C:\Users\MARTHA\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:14.986888 Finished saving settings file "C:\Users\MARTHA\.VirtualBox\VirtualBox.xml" 00:00:14.986992 Saving settings file "C:\Users\MARTHA\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:15.013446 Finished saving settings file "C:\Users\MARTHA\.VirtualBox\VirtualBox.xml" 00:00:15.014559 DeleteVM Saving settings file "C:\Users\MARTHA\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:15.050705 DeleteVM Finished saving settings file "C:\Users\MARTHA\.VirtualBox\VirtualBox.xml" 00:00:20.074229 main VirtualBox: object deletion starts 00:00:20.079259 main HostDnsMonitor: shutting down ... 00:00:20.079432 main HostDnsMonitor: shut down 00:00:20.089332 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d644ad1e-c501-4fc7-9ab6-aa6d763bc540} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:20.090370 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: 5-02-26 18:16:32 (18104): Command: VBoxManage -q createvm --name "boinc_3e235e9f3bdf0732" --basefolder "C:\ProgramData\BOINC\slots\2" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_3e235e9f3bdf0732' is created and registered. UUID: 93245eff-fa08-4b5b-a8f3-0827efa48500 Settings file: 'C:\ProgramData\BOINC\slots\2\boinc_3e235e9f3bdf0732\boinc_3e235e9f3bdf0732.vbox' 2025-02-26 18:16:32 (18104): Command: VBoxManage -q modifyvm "boinc_3e235e9f3bdf0732" --description "CMS_837297_1740614310.552412_0" Exit Code: 0 Output: 2025-02-26 18:16:32 (18104): Command: VBoxManage -q modifyvm "boinc_3e235e9f3bdf0732" --memory 4584 Exit Code: 0 Output: 2025-02-26 18:16:32 (18104): Command: VBoxManage -q modifyvm "boinc_3e235e9f3bdf0732" --cpus 4 Exit Code: 0 Output: 2025-02-26 18:16:33 (18104): Command: VBoxManage -q modifyvm "boinc_3e235e9f3bdf0732" --acpi on --ioapic on --rtcuseutc off Exit Code: 0 Output: 2025-02-26 18:16:33 (18104): Command: VBoxManage -q modifyvm "boinc_3e235e9f3bdf0732" --vram 16 --graphicscontroller VBoxVGA Exit Code: 0 Output: 2025-02-26 18:16:33 (18104): Command: VBoxManage -q modifyvm "boinc_3e235e9f3bdf0732" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2025-02-26 18:16:34 (18104): Command: VBoxManage -q modifyvm "boinc_3e235e9f3bdf0732" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2025-02-26 18:16:34 (18104): Command: VBoxManage -q modifyvm "boinc_3e235e9f3bdf0732" --cableconnected1 on Exit Code: 0 Output: 2025-02-26 18:16:34 (18104): Command: VBoxManage -q modifyvm "boinc_3e235e9f3bdf0732" --usb off Exit Code: 0 Output: 2025-02-26 18:16:34 (18104): Command: VBoxManage -q modifyvm "boinc_3e235e9f3bdf0732" --uart1 off --uart2 off Exit Code: 0 Output: 2025-02-26 18:16:35 (18104): Command: VBoxManage -q modifyvm "boinc_3e235e9f3bdf0732" --lpt1 off --lpt2 off Exit Code: 0 Output: 2025-02-26 18:16:35 (18104): Command: VBoxManage -q modifyvm "boinc_3e235e9f3bdf0732" --audio-enabled off Exit Code: 0 Output: 2025-02-26 18:16:35 (18104): Command: VBoxManage -q modifyvm "boinc_3e235e9f3bdf0732" --clipboard disabled Exit Code: 0 Output: 2025-02-26 18:16:35 (18104): Command: VBoxManage -q modifyvm "boinc_3e235e9f3bdf0732" --draganddrop disabled Exit Code: 0 Output: 2025-02-26 18:16:36 (18104): Command: VBoxManage -q storagectl "boinc_3e235e9f3bdf0732" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2025-02-26 18:16:36 (18104): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2025_01_16_prod.vdi" Exit Code: 0 Output: UUID: 3da9ab36-1206-4cc3-8a9a-8d4138ab45c5 Parent UUID: base State: created Type: multiattach Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\CMS_2025_01_16_prod.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 3853 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-26 18:16:36 (18104): Command: VBoxManage -q storageattach "boinc_3e235e9f3bdf0732" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2025_01_16_prod.vdi" Exit Code: -2135228409 Output: VBoxManage.exe: error: Cannot attach medium 'C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\CMS_2025_01_16_prod.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 786 of file VBoxManageStorageController.cpp 2025-02-26 18:16:36 (18104): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2025_01_16_prod.vdi" Exit Code: 0 Output: UUID: 3da9ab36-1206-4cc3-8a9a-8d4138ab45c5 Parent UUID: base State: created Type: multiattach Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\CMS_2025_01_16_prod.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 3853 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-26 18:16:37 (18104): Command: VBoxManage -q closemedium disk "C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\CMS_2025_01_16_prod.vdi" Exit Code: 0 Output: 2025-02-26 18:16:37 (18104): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2025_01_16_prod.vdi" Exit Code: 0 Output: UUID: 3da9ab36-1206-4cc3-8a9a-8d4138ab45c5 Parent UUID: base State: created Type: normal (base) Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\CMS_2025_01_16_prod.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 3853 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-26 18:16:37 (18104): Command: VBoxManage -q storageattach "boinc_3e235e9f3bdf0732" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2025_01_16_prod.vdi" Exit Code: 0 Output: 2025-02-26 18:16:38 (18104): Command: VBoxManage -q storageattach "boinc_3e235e9f3bdf0732" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none Exit Code: 0 Output: 2025-02-26 18:16:38 (18104): Command: VBoxManage -q storageattach "boinc_3e235e9f3bdf0732" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/CMS_2025_01_16_prod.vdi" Exit Code: 0 Output: 2025-02-26 18:16:38 (18104): Command: VBoxManage -q storageattach "boinc_3e235e9f3bdf0732" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2025-02-26 18:16:38 (18104): Command: VBoxManage -q bandwidthctl "boinc_3e235e9f3bdf0732" add "boinc_3e235e9f3bdf0732_net" --type network --limit 1024G Exit Code: 0 Output: 2025-02-26 18:16:39 (18104): Command: VBoxManage -q modifyvm "boinc_3e235e9f3bdf0732" --natpf1 ",tcp,127.0.0.1,53261,,80" Exit Code: 0 Output: 2025-02-26 18:16:39 (18104): Command: VBoxManage -q list extpacks Exit Code: 0 Output: Extension Packs: 0 2025-02-26 18:16:39 (18104): Command: VBoxManage -q sharedfolder add "boinc_3e235e9f3bdf0732" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\2/shared" Exit Code: 0 Output: 2025-02-26 18:16:45 (18104): Command: VBoxManage -q startvm "boinc_3e235e9f3bdf0732" --type headless Exit Code: -2147467259 Output: VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole Waiting for VM "boinc_3e235e9f3bdf0732" to power on... 2025-02-26 18:16:45 (18104): Command: VBoxManage -q snapshot "boinc_3e235e9f3bdf0732" list Exit Code: -108 Output: This machine does not have any snapshots 2025-02-26 18:16:45 (18104): Command: VBoxManage -q bandwidthctl "boinc_3e235e9f3bdf0732" remove "boinc_3e235e9f3bdf0732_net" Exit Code: 0 Output: VBoxManage.exe: error: Bandwidth groups cannot be deleted while the VM is running 2025-02-26 18:16:45 (18104): Command: VBoxManage -q unregistervm "boinc_3e235e9f3bdf0732" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 2025-02-26 18:16:51 (18104): called boinc_finish(-2147467259) </stderr_txt> ]]>
©2025 CERN