Name | XmfMDmRkI76n9Rq4apOajLDm4fhM0noT9bVoFjIUDmedgKDm06OBIo_0 |
Workunit | 230563399 |
Created | 25 Feb 2025, 22:39:09 UTC |
Sent | 26 Feb 2025, 0:26:59 UTC |
Report deadline | 6 Mar 2025, 0:26:59 UTC |
Received | 26 Feb 2025, 1:06:58 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | 1 (0x00000001) Unknown error code |
Computer ID | 10848068 |
Run time | 5 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 44.98 GFLOPS |
Application version | ATLAS Simulation v3.01 (vbox64_mt_mcore_atlas) windows_x86_64 |
Peak working set size | 7.99 MB |
Peak swap size | 2.06 MB |
Peak disk usage | 239.95 MB |
<core_client_version>7.24.1</core_client_version> <![CDATA[ <message> Incorrect function. (0x1) - exit code 1 (0x1)</message> <stderr_txt> 2025-02-25 18:37:45 (27308): Detected: vboxwrapper 26206 2025-02-25 18:37:45 (27308): Detected: BOINC client v7.24.1 2025-02-25 18:37:46 (27308): Detected: VirtualBox VboxManage Interface (Version: 7.0.6) 2025-02-25 18:37:46 (27308): Successfully copied 'init_data.xml' to the shared directory. 2025-02-25 18:37:46 (27308): Create VM. (boinc_01db94599f7476fc, slot#14) 2025-02-25 18:37:47 (27308): Setting Memory Size for VM. (4800MB) 2025-02-25 18:37:47 (27308): Setting CPU Count for VM. (8) 2025-02-25 18:37:47 (27308): Setting Chipset Options for VM. 2025-02-25 18:37:48 (27308): Setting Graphics Controller Options for VM. 2025-02-25 18:37:48 (27308): Setting Boot Options for VM. 2025-02-25 18:37:48 (27308): Setting Network Configuration for NAT. 2025-02-25 18:37:49 (27308): Enabling VM Network Access. 2025-02-25 18:37:49 (27308): Disabling USB Support for VM. 2025-02-25 18:37:49 (27308): Disabling COM Port Support for VM. 2025-02-25 18:37:49 (27308): Disabling LPT Port Support for VM. 2025-02-25 18:37:50 (27308): Disabling Audio Support for VM. 2025-02-25 18:37:50 (27308): Disabling Clipboard Support for VM. 2025-02-25 18:37:50 (27308): Disabling Drag and Drop Support for VM. 2025-02-25 18:37:50 (27308): Adding storage controller(s) to VM. 2025-02-25 18:37:51 (27308): Adding virtual disk drive to VM. (ATLAS_vbox_3.01_image.vdi) 2025-02-25 18:37:54 (27308): Adding VirtualBox Guest Additions to VM. 2025-02-25 18:37:54 (27308): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2025-02-25 18:37:54 (27308): forwarding host port 52132 to guest port 80 2025-02-25 18:37:54 (27308): Enabling remote desktop for VM. 2025-02-25 18:37:55 (27308): Required extension pack not installed, remote desktop not enabled. 2025-02-25 18:37:55 (27308): Enabling shared directory for VM. 2025-02-25 18:37:55 (27308): Starting VM using VBoxManage interface. (boinc_01db94599f7476fc, slot#14) 2025-02-25 18:37:56 (27308): Error in start VM for VM: 1 Command: VBoxManage -q startvm "boinc_01db94599f7476fc" --type headless Output: VBoxManage.exe: error: The virtual machine 'boinc_01db94599f7476fc' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\14\boinc_01db94599f7476fc\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_01db94599f7476fc" to power on... 2025-02-25 18:37:56 (27308): VM failed to start. 2025-02-25 18:37:56 (27308): Could not start 2025-02-25 18:37:56 (27308): ERROR: VM failed to start 2025-02-25 18:37:56 (27308): Powering off VM. 2025-02-25 18:37:56 (27308): Deregistering VM. (boinc_01db94599f7476fc, slot#14) 2025-02-25 18:37:56 (27308): Removing network bandwidth throttle group from VM. 2025-02-25 18:37:56 (27308): Removing VM from VirtualBox. Hypervisor System Log: 00:00:07.610540 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.610668 Saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:07.614775 Finished saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml" 00:00:07.615018 Saving settings file "C:\ProgramData\BOINC\slots\14\boinc_01db94599f7476fc\boinc_01db94599f7476fc.vbox" with version "1.19-windows" 00:00:07.618313 Finished saving settings file "C:\ProgramData\BOINC\slots\14\boinc_01db94599f7476fc\boinc_01db94599f7476fc.vbox" 00:00:07.873427 Saving settings file "C:\ProgramData\BOINC\slots\14\boinc_01db94599f7476fc\boinc_01db94599f7476fc.vbox" with version "1.19-windows" 00:00:07.877247 Finished saving settings file "C:\ProgramData\BOINC\slots\14\boinc_01db94599f7476fc\boinc_01db94599f7476fc.vbox" 00:00:08.138192 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.138559 Saving settings file "C:\ProgramData\BOINC\slots\14\boinc_01db94599f7476fc\boinc_01db94599f7476fc.vbox" with version "1.19-windows" 00:00:08.147468 Finished saving settings file "C:\ProgramData\BOINC\slots\14\boinc_01db94599f7476fc\boinc_01db94599f7476fc.vbox" 00:00:08.147608 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.149804 Saving settings file "C:\ProgramData\BOINC\slots\14\boinc_01db94599f7476fc\boinc_01db94599f7476fc.vbox" with version "1.19-windows" 00:00:08.152753 Finished saving settings file "C:\ProgramData\BOINC\slots\14\boinc_01db94599f7476fc\boinc_01db94599f7476fc.vbox" 00:00:08.153051 Saving settings file "C:\ProgramData\BOINC\slots\14\boinc_01db94599f7476fc\boinc_01db94599f7476fc.vbox" with version "1.19-windows" 00:00:08.156028 Finished saving settings file "C:\ProgramData\BOINC\slots\14\boinc_01db94599f7476fc\boinc_01db94599f7476fc.vbox" 00:00:08.401672 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.402812 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.402932 Saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:08.406664 Finished saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml" 00:00:08.406833 Saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:08.410265 Finished saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml" 00:00:08.410496 Saving settings file "C:\ProgramData\BOINC\slots\14\boinc_01db94599f7476fc\boinc_01db94599f7476fc.vbox" with version "1.19-windows" 00:00:08.413569 Finished saving settings file "C:\ProgramData\BOINC\slots\14\boinc_01db94599f7476fc\boinc_01db94599f7476fc.vbox" 00:00:08.667463 Saving settings file "C:\ProgramData\BOINC\slots\14\boinc_01db94599f7476fc\boinc_01db94599f7476fc.vbox" with version "1.19-windows" 00:00:08.671181 Finished saving settings file "C:\ProgramData\BOINC\slots\14\boinc_01db94599f7476fc\boinc_01db94599f7476fc.vbox" 00:00:08.931399 Saving settings file "C:\ProgramData\BOINC\slots\14\boinc_01db94599f7476fc\boinc_01db94599f7476fc.vbox" with version "1.19-windows" 00:00:08.934868 Finished saving settings file "C:\ProgramData\BOINC\slots\14\boinc_01db94599f7476fc\boinc_01db94599f7476fc.vbox" 00:00:09.461783 Saving settings file "C:\ProgramData\BOINC\slots\14\boinc_01db94599f7476fc\boinc_01db94599f7476fc.vbox" with version "1.19-windows" 00:00:09.465434 Finished saving settings file "C:\ProgramData\BOINC\slots\14\boinc_01db94599f7476fc\boinc_01db94599f7476fc.vbox" 00:00:09.725062 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={Ńo extension pack providing a cryptographic support module could be found}, preserve=false aResultDetail=0 00:00:09.729500 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.729555 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.734891 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:09.993985 Launched VM: 2047679072 pid: 46224 (0xb490) frontend: headless name: boinc_01db94599f7476fc 00:00:10.611043 Watcher ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The virtual machine 'boinc_01db94599f7476fc' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\14\boinc_01db94599f7476fc\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0 00:00:10.611314 Watcher Reaper: Pid 46224 (0xb490) exited normally: 1 (0x1) 00:00:10.649821 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:10.684334 Saving settings file "C:\ProgramData\BOINC\slots\14\boinc_01db94599f7476fc\boinc_01db94599f7476fc.vbox" with version "1.19-windows" 00:00:10.687853 Finished saving settings file "C:\ProgramData\BOINC\slots\14\boinc_01db94599f7476fc\boinc_01db94599f7476fc.vbox" 00:00:10.941754 Saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:10.945244 Finished saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml" 00:00:10.945311 Saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:10.948331 Finished saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml" 00:00:10.948944 DeleteVM Saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:10.952094 DeleteVM Finished saving settings file "C:\Users\Work\.VirtualBox\VirtualBox.xml" 00:00:15.957954 main VirtualBox: object deletion starts 00:00:15.958426 main HostDnsMonitor: shutting down ... 00:00:15.958476 main HostDnsMonitor: shut down 00:00:15.960193 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:15.960331 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: C\slots\14/vm_image.vdi" Exit Code: -2135228412 Output: VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\14\vm_image.vdi' (VERR_FILE_NOT_FOUND) VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 205 of file VBoxManageDisk.cpp 2025-02-25 18:37:47 (27308): Command: VBoxManage -q createvm --name "boinc_01db94599f7476fc" --basefolder "C:\ProgramData\BOINC\slots\14" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_01db94599f7476fc' is created and registered. UUID: 34401a9f-6c40-476f-86b5-45c6142857b0 Settings file: 'C:\ProgramData\BOINC\slots\14\boinc_01db94599f7476fc\boinc_01db94599f7476fc.vbox' 2025-02-25 18:37:47 (27308): Command: VBoxManage -q modifyvm "boinc_01db94599f7476fc" --description "XmfMDmRkI76n9Rq4apOajLDm4fhM0noT9bVoFjIUDmedgKDm06OBIo_0" Exit Code: 0 Output: 2025-02-25 18:37:47 (27308): Command: VBoxManage -q modifyvm "boinc_01db94599f7476fc" --memory 4800 Exit Code: 0 Output: 2025-02-25 18:37:47 (27308): Command: VBoxManage -q modifyvm "boinc_01db94599f7476fc" --cpus 8 Exit Code: 0 Output: 2025-02-25 18:37:48 (27308): Command: VBoxManage -q modifyvm "boinc_01db94599f7476fc" --acpi on --ioapic on --rtcuseutc off Exit Code: 0 Output: 2025-02-25 18:37:48 (27308): Command: VBoxManage -q modifyvm "boinc_01db94599f7476fc" --vram 16 --graphicscontroller VBoxVGA Exit Code: 0 Output: 2025-02-25 18:37:48 (27308): Command: VBoxManage -q modifyvm "boinc_01db94599f7476fc" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2025-02-25 18:37:49 (27308): Command: VBoxManage -q modifyvm "boinc_01db94599f7476fc" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2025-02-25 18:37:49 (27308): Command: VBoxManage -q modifyvm "boinc_01db94599f7476fc" --cableconnected1 on Exit Code: 0 Output: 2025-02-25 18:37:49 (27308): Command: VBoxManage -q modifyvm "boinc_01db94599f7476fc" --usb off Exit Code: 0 Output: 2025-02-25 18:37:49 (27308): Command: VBoxManage -q modifyvm "boinc_01db94599f7476fc" --uart1 off --uart2 off Exit Code: 0 Output: 2025-02-25 18:37:50 (27308): Command: VBoxManage -q modifyvm "boinc_01db94599f7476fc" --lpt1 off --lpt2 off Exit Code: 0 Output: 2025-02-25 18:37:50 (27308): Command: VBoxManage -q modifyvm "boinc_01db94599f7476fc" --audio none Exit Code: 0 Output: Warning: --audio is deprecated and will be removed soon. Use --audio-driver instead! 2025-02-25 18:37:50 (27308): Command: VBoxManage -q modifyvm "boinc_01db94599f7476fc" --clipboard disabled Exit Code: 0 Output: 2025-02-25 18:37:50 (27308): Command: VBoxManage -q modifyvm "boinc_01db94599f7476fc" --draganddrop disabled Exit Code: 0 Output: 2025-02-25 18:37:51 (27308): Command: VBoxManage -q storagectl "boinc_01db94599f7476fc" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2025-02-25 18:37:51 (27308): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: UUID: ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8 Parent UUID: base State: created Type: multiattach Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 4204 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-25 18:37:51 (27308): Command: VBoxManage -q storageattach "boinc_01db94599f7476fc" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: -2135228409 Output: VBoxManage.exe: error: Cannot attach medium 'C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 785 of file VBoxManageStorageController.cpp 2025-02-25 18:37:51 (27308): Command: VBoxManage -q closemedium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-25 18:37:53 (27308): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: UUID: ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8 Parent UUID: base State: created Type: normal (base) Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 4204 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-25 18:37:53 (27308): Command: VBoxManage -q storageattach "boinc_01db94599f7476fc" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-25 18:37:53 (27308): Command: VBoxManage -q storageattach "boinc_01db94599f7476fc" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none Exit Code: 0 Output: 2025-02-25 18:37:54 (27308): Command: VBoxManage -q storageattach "boinc_01db94599f7476fc" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-25 18:37:54 (27308): Command: VBoxManage -q storageattach "boinc_01db94599f7476fc" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2025-02-25 18:37:54 (27308): Command: VBoxManage -q bandwidthctl "boinc_01db94599f7476fc" add "boinc_01db94599f7476fc_net" --type network --limit 1024G Exit Code: 0 Output: 2025-02-25 18:37:54 (27308): Command: VBoxManage -q modifyvm "boinc_01db94599f7476fc" --natpf1 ",tcp,127.0.0.1,52132,,80" Exit Code: 0 Output: 2025-02-25 18:37:55 (27308): Command: VBoxManage -q list extpacks Exit Code: 0 Output: Extension Packs: 0 2025-02-25 18:37:55 (27308): Command: VBoxManage -q sharedfolder add "boinc_01db94599f7476fc" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\14/shared" Exit Code: 0 Output: 2025-02-25 18:37:56 (27308): Command: VBoxManage -q startvm "boinc_01db94599f7476fc" --type headless Exit Code: 1 Output: VBoxManage.exe: error: The virtual machine 'boinc_01db94599f7476fc' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\14\boinc_01db94599f7476fc\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_01db94599f7476fc" to power on... 2025-02-25 18:37:56 (27308): Command: VBoxManage -q snapshot "boinc_01db94599f7476fc" list Exit Code: -108 Output: This machine does not have any snapshots 2025-02-25 18:37:56 (27308): Command: VBoxManage -q bandwidthctl "boinc_01db94599f7476fc" remove "boinc_01db94599f7476fc_net" Exit Code: 0 Output: 2025-02-25 18:37:56 (27308): Command: VBoxManage -q unregistervm "boinc_01db94599f7476fc" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 18:38:01 (27308): called boinc_finish(1) </stderr_txt> ]]>
©2025 CERN