Name | uJOLDmIC766n9Rq4apOajLDm4fhM0noT9bVoFjIUDmzIfKDmKrtZXo_0 |
Workunit | 230549229 |
Created | 25 Feb 2025, 10:19:17 UTC |
Sent | 25 Feb 2025, 10:19:23 UTC |
Report deadline | 5 Mar 2025, 10:19:23 UTC |
Received | 25 Feb 2025, 11:44:23 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | 1 (0x00000001) Unknown error code |
Computer ID | 10862932 |
Run time | 5 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 43.47 GFLOPS |
Application version | ATLAS Simulation v3.01 (vbox64_mt_mcore_atlas) windows_x86_64 |
Peak working set size | 7.97 MB |
Peak swap size | 2.03 MB |
Peak disk usage | 237.25 MB |
<core_client_version>8.0.2</core_client_version> <![CDATA[ <message> Funzione non corretta. (0x1) - exit code 1 (0x1)</message> <stderr_txt> 2025-02-25 12:40:09 (12660): Detected: vboxwrapper 26206 2025-02-25 12:40:09 (12660): Detected: BOINC client v8.0.2 2025-02-25 12:40:10 (12660): Detected: VirtualBox VboxManage Interface (Version: 7.0.6) 2025-02-25 12:40:10 (12660): Successfully copied 'init_data.xml' to the shared directory. 2025-02-25 12:40:11 (12660): Create VM. (boinc_81ab6615075adaa2, slot#0) 2025-02-25 12:40:11 (12660): Setting Memory Size for VM. (4800MB) 2025-02-25 12:40:11 (12660): Setting CPU Count for VM. (8) 2025-02-25 12:40:12 (12660): Setting Chipset Options for VM. 2025-02-25 12:40:12 (12660): Setting Graphics Controller Options for VM. 2025-02-25 12:40:12 (12660): Setting Boot Options for VM. 2025-02-25 12:40:13 (12660): Setting Network Configuration for NAT. 2025-02-25 12:40:13 (12660): Enabling VM Network Access. 2025-02-25 12:40:13 (12660): Disabling USB Support for VM. 2025-02-25 12:40:13 (12660): Disabling COM Port Support for VM. 2025-02-25 12:40:14 (12660): Disabling LPT Port Support for VM. 2025-02-25 12:40:14 (12660): Disabling Audio Support for VM. 2025-02-25 12:40:14 (12660): Disabling Clipboard Support for VM. 2025-02-25 12:40:14 (12660): Disabling Drag and Drop Support for VM. 2025-02-25 12:40:15 (12660): Adding storage controller(s) to VM. 2025-02-25 12:40:15 (12660): Adding virtual disk drive to VM. (ATLAS_vbox_3.01_image.vdi) 2025-02-25 12:40:18 (12660): Adding VirtualBox Guest Additions to VM. 2025-02-25 12:40:18 (12660): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2025-02-25 12:40:18 (12660): forwarding host port 50228 to guest port 80 2025-02-25 12:40:18 (12660): Enabling remote desktop for VM. 2025-02-25 12:40:19 (12660): Required extension pack not installed, remote desktop not enabled. 2025-02-25 12:40:19 (12660): Enabling shared directory for VM. 2025-02-25 12:40:19 (12660): Starting VM using VBoxManage interface. (boinc_81ab6615075adaa2, slot#0) 2025-02-25 12:40:20 (12660): Error in start VM for VM: 1 Command: VBoxManage -q startvm "boinc_81ab6615075adaa2" --type headless Output: VBoxManage.exe: error: The virtual machine 'boinc_81ab6615075adaa2' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\0\boinc_81ab6615075adaa2\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_81ab6615075adaa2" to power on... 2025-02-25 12:40:20 (12660): VM failed to start. 2025-02-25 12:40:20 (12660): Could not start 2025-02-25 12:40:20 (12660): ERROR: VM failed to start 2025-02-25 12:40:20 (12660): Powering off VM. 2025-02-25 12:40:20 (12660): Deregistering VM. (boinc_81ab6615075adaa2, slot#0) 2025-02-25 12:40:20 (12660): Removing network bandwidth throttle group from VM. 2025-02-25 12:40:20 (12660): Removing VM from VirtualBox. Hypervisor System Log: 00:00:08.215917 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.216271 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.216746 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_81ab6615075adaa2\boinc_81ab6615075adaa2.vbox" with version "1.19-windows" 00:00:08.218818 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_81ab6615075adaa2\boinc_81ab6615075adaa2.vbox" 00:00:08.322107 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_e5a8637ad92902a6\boinc_e5a8637ad92902a6.vbox" with version "1.19-windows" 00:00:08.324401 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_e5a8637ad92902a6\boinc_e5a8637ad92902a6.vbox" 00:00:08.475850 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_81ab6615075adaa2\boinc_81ab6615075adaa2.vbox" with version "1.19-windows" 00:00:08.477545 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_81ab6615075adaa2\boinc_81ab6615075adaa2.vbox" 00:00:08.583145 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={Ńo extension pack providing a cryptographic support module could be found}, preserve=false aResultDetail=0 00:00:08.589408 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.589493 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.596477 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:08.742558 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_81ab6615075adaa2\boinc_81ab6615075adaa2.vbox" with version "1.19-windows" 00:00:08.745054 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_81ab6615075adaa2\boinc_81ab6615075adaa2.vbox" 00:00:08.850190 Launched VM: 2875972064 pid: 10372 (0x2884) frontend: headless name: boinc_e5a8637ad92902a6 00:00:09.202922 Watcher ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The virtual machine 'boinc_e5a8637ad92902a6' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\1\boinc_e5a8637ad92902a6\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0 00:00:09.203305 Watcher Reaper: Pid 10372 (0x2884) exited normally: 1 (0x1) 00:00:09.245567 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:09.268900 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_81ab6615075adaa2\boinc_81ab6615075adaa2.vbox" with version "1.19-windows" 00:00:09.271343 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_81ab6615075adaa2\boinc_81ab6615075adaa2.vbox" 00:00:09.282454 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_e5a8637ad92902a6\boinc_e5a8637ad92902a6.vbox" with version "1.19-windows" 00:00:09.284305 Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_e5a8637ad92902a6\boinc_e5a8637ad92902a6.vbox" 00:00:09.536537 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={Ńo extension pack providing a cryptographic support module could be found}, preserve=false aResultDetail=0 00:00:09.542276 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.542355 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.548084 Saving settings file "C:\Users\ottic\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:09.548874 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:09.550538 Finished saving settings file "C:\Users\ottic\.VirtualBox\VirtualBox.xml" 00:00:09.550658 Saving settings file "C:\Users\ottic\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:09.552429 Finished saving settings file "C:\Users\ottic\.VirtualBox\VirtualBox.xml" 00:00:09.553303 DeleteVM Saving settings file "C:\Users\ottic\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:09.555794 DeleteVM Finished saving settings file "C:\Users\ottic\.VirtualBox\VirtualBox.xml" 00:00:09.806890 Launched VM: 2875932176 pid: 3076 (0xc04) frontend: headless name: boinc_81ab6615075adaa2 00:00:10.143825 Watcher ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The virtual machine 'boinc_81ab6615075adaa2' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\0\boinc_81ab6615075adaa2\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0 00:00:10.144169 Watcher Reaper: Pid 3076 (0xc04) exited normally: 1 (0x1) 00:00:10.187132 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:10.222854 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_81ab6615075adaa2\boinc_81ab6615075adaa2.vbox" with version "1.19-windows" 00:00:10.225084 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_81ab6615075adaa2\boinc_81ab6615075adaa2.vbox" 00:00:10.479246 Saving settings file "C:\Users\ottic\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:10.481653 Finished saving settings file "C:\Users\ottic\.VirtualBox\VirtualBox.xml" 00:00:10.481730 Saving settings file "C:\Users\ottic\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:10.484078 Finished saving settings file "C:\Users\ottic\.VirtualBox\VirtualBox.xml" 00:00:10.484872 DeleteVM Saving settings file "C:\Users\ottic\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:10.487352 DeleteVM Finished saving settings file "C:\Users\ottic\.VirtualBox\VirtualBox.xml" 00:00:15.501962 main VirtualBox: object deletion starts 00:00:15.502688 main HostDnsMonitor: shutting down ... 00:00:15.502745 main HostDnsMonitor: shut down 00:00:15.504511 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:15.504730 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: a\BOINC\slots\0/vm_image.vdi" Exit Code: -2135228412 Output: VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\0\vm_image.vdi' (VERR_FILE_NOT_FOUND) VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 205 of file VBoxManageDisk.cpp 2025-02-25 12:40:11 (12660): Command: VBoxManage -q createvm --name "boinc_81ab6615075adaa2" --basefolder "C:\ProgramData\BOINC\slots\0" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_81ab6615075adaa2' is created and registered. UUID: d77baaac-6f0d-464d-b108-c1eb39186e99 Settings file: 'C:\ProgramData\BOINC\slots\0\boinc_81ab6615075adaa2\boinc_81ab6615075adaa2.vbox' 2025-02-25 12:40:11 (12660): Command: VBoxManage -q modifyvm "boinc_81ab6615075adaa2" --description "uJOLDmIC766n9Rq4apOajLDm4fhM0noT9bVoFjIUDmzIfKDmKrtZXo_0" Exit Code: 0 Output: 2025-02-25 12:40:11 (12660): Command: VBoxManage -q modifyvm "boinc_81ab6615075adaa2" --memory 4800 Exit Code: 0 Output: 2025-02-25 12:40:12 (12660): Command: VBoxManage -q modifyvm "boinc_81ab6615075adaa2" --cpus 8 Exit Code: 0 Output: 2025-02-25 12:40:12 (12660): Command: VBoxManage -q modifyvm "boinc_81ab6615075adaa2" --acpi on --ioapic on --rtcuseutc off Exit Code: 0 Output: 2025-02-25 12:40:12 (12660): Command: VBoxManage -q modifyvm "boinc_81ab6615075adaa2" --vram 16 --graphicscontroller VBoxVGA Exit Code: 0 Output: 2025-02-25 12:40:13 (12660): Command: VBoxManage -q modifyvm "boinc_81ab6615075adaa2" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2025-02-25 12:40:13 (12660): Command: VBoxManage -q modifyvm "boinc_81ab6615075adaa2" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2025-02-25 12:40:13 (12660): Command: VBoxManage -q modifyvm "boinc_81ab6615075adaa2" --cableconnected1 on Exit Code: 0 Output: 2025-02-25 12:40:13 (12660): Command: VBoxManage -q modifyvm "boinc_81ab6615075adaa2" --usb off Exit Code: 0 Output: 2025-02-25 12:40:14 (12660): Command: VBoxManage -q modifyvm "boinc_81ab6615075adaa2" --uart1 off --uart2 off Exit Code: 0 Output: 2025-02-25 12:40:14 (12660): Command: VBoxManage -q modifyvm "boinc_81ab6615075adaa2" --lpt1 off --lpt2 off Exit Code: 0 Output: 2025-02-25 12:40:14 (12660): Command: VBoxManage -q modifyvm "boinc_81ab6615075adaa2" --audio none Exit Code: 0 Output: Warning: --audio is deprecated and will be removed soon. Use --audio-driver instead! 2025-02-25 12:40:14 (12660): Command: VBoxManage -q modifyvm "boinc_81ab6615075adaa2" --clipboard disabled Exit Code: 0 Output: 2025-02-25 12:40:15 (12660): Command: VBoxManage -q modifyvm "boinc_81ab6615075adaa2" --draganddrop disabled Exit Code: 0 Output: 2025-02-25 12:40:15 (12660): Command: VBoxManage -q storagectl "boinc_81ab6615075adaa2" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2025-02-25 12:40:15 (12660): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: UUID: ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8 Parent UUID: base State: created Type: multiattach Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 4204 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-25 12:40:15 (12660): Command: VBoxManage -q storageattach "boinc_81ab6615075adaa2" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: -2135228409 Output: VBoxManage.exe: error: Cannot attach medium 'C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 785 of file VBoxManageStorageController.cpp 2025-02-25 12:40:16 (12660): Command: VBoxManage -q closemedium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-25 12:40:17 (12660): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: UUID: ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8 Parent UUID: base State: created Type: normal (base) Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 4204 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-25 12:40:17 (12660): Command: VBoxManage -q storageattach "boinc_81ab6615075adaa2" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-25 12:40:17 (12660): Command: VBoxManage -q storageattach "boinc_81ab6615075adaa2" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none Exit Code: 0 Output: 2025-02-25 12:40:18 (12660): Command: VBoxManage -q storageattach "boinc_81ab6615075adaa2" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-25 12:40:18 (12660): Command: VBoxManage -q storageattach "boinc_81ab6615075adaa2" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2025-02-25 12:40:18 (12660): Command: VBoxManage -q bandwidthctl "boinc_81ab6615075adaa2" add "boinc_81ab6615075adaa2_net" --type network --limit 1024G Exit Code: 0 Output: 2025-02-25 12:40:18 (12660): Command: VBoxManage -q modifyvm "boinc_81ab6615075adaa2" --natpf1 ",tcp,127.0.0.1,50228,,80" Exit Code: 0 Output: 2025-02-25 12:40:19 (12660): Command: VBoxManage -q list extpacks Exit Code: 0 Output: Extension Packs: 0 2025-02-25 12:40:19 (12660): Command: VBoxManage -q sharedfolder add "boinc_81ab6615075adaa2" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\0/shared" Exit Code: 0 Output: 2025-02-25 12:40:20 (12660): Command: VBoxManage -q startvm "boinc_81ab6615075adaa2" --type headless Exit Code: 1 Output: VBoxManage.exe: error: The virtual machine 'boinc_81ab6615075adaa2' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\0\boinc_81ab6615075adaa2\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_81ab6615075adaa2" to power on... 2025-02-25 12:40:20 (12660): Command: VBoxManage -q snapshot "boinc_81ab6615075adaa2" list Exit Code: -108 Output: This machine does not have any snapshots 2025-02-25 12:40:20 (12660): Command: VBoxManage -q bandwidthctl "boinc_81ab6615075adaa2" remove "boinc_81ab6615075adaa2_net" Exit Code: 0 Output: 2025-02-25 12:40:20 (12660): Command: VBoxManage -q unregistervm "boinc_81ab6615075adaa2" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 12:40:25 (12660): called boinc_finish(1) </stderr_txt> ]]>
©2025 CERN