Name | OlQNDmNJn56nsSi4ap6QjLDmwznN0nGgGQJmkKkKDmFqsKDmvBoCEo_0 |
Workunit | 230500467 |
Created | 21 Feb 2025, 18:52:25 UTC |
Sent | 21 Feb 2025, 23:43:38 UTC |
Report deadline | 1 Mar 2025, 23:43:38 UTC |
Received | 21 Feb 2025, 23:49:13 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | 1 (0x00000001) Unknown error code |
Computer ID | 10869666 |
Run time | 15 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 6.00 GFLOPS |
Application version | ATLAS Simulation v3.01 (vbox64_mt_mcore_atlas) windows_x86_64 |
Peak working set size | 7.96 MB |
Peak swap size | 2.06 MB |
Peak disk usage | 324.85 MB |
<core_client_version>8.0.4</core_client_version> <![CDATA[ <message> Incorrect function. (0x1) - exit code 1 (0x1)</message> <stderr_txt> 2025-02-21 18:43:56 (22316): Detected: vboxwrapper 26206 2025-02-21 18:43:56 (22316): Detected: BOINC client v8.0.4 2025-02-21 18:43:57 (22316): Detected: VirtualBox VboxManage Interface (Version: 7.0.6) 2025-02-21 18:43:57 (22316): Successfully copied 'init_data.xml' to the shared directory. 2025-02-21 18:43:57 (22316): Create VM. (boinc_7119dfb4c886e358, slot#0) 2025-02-21 18:43:58 (22316): Setting Memory Size for VM. (4600MB) 2025-02-21 18:43:58 (22316): Setting CPU Count for VM. (6) 2025-02-21 18:43:58 (22316): Setting Chipset Options for VM. 2025-02-21 18:43:59 (22316): Setting Graphics Controller Options for VM. 2025-02-21 18:43:59 (22316): Setting Boot Options for VM. 2025-02-21 18:43:59 (22316): Setting Network Configuration for NAT. 2025-02-21 18:43:59 (22316): Enabling VM Network Access. 2025-02-21 18:44:00 (22316): Disabling USB Support for VM. 2025-02-21 18:44:00 (22316): Disabling COM Port Support for VM. 2025-02-21 18:44:00 (22316): Disabling LPT Port Support for VM. 2025-02-21 18:44:00 (22316): Disabling Audio Support for VM. 2025-02-21 18:44:01 (22316): Disabling Clipboard Support for VM. 2025-02-21 18:44:01 (22316): Disabling Drag and Drop Support for VM. 2025-02-21 18:44:01 (22316): Adding storage controller(s) to VM. 2025-02-21 18:44:02 (22316): Adding virtual disk drive to VM. (ATLAS_vbox_3.01_image.vdi) 2025-02-21 18:44:04 (22316): Adding VirtualBox Guest Additions to VM. 2025-02-21 18:44:05 (22316): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2025-02-21 18:44:05 (22316): forwarding host port 65149 to guest port 80 2025-02-21 18:44:05 (22316): Enabling remote desktop for VM. 2025-02-21 18:44:05 (22316): Required extension pack not installed, remote desktop not enabled. 2025-02-21 18:44:05 (22316): Enabling shared directory for VM. 2025-02-21 18:44:06 (22316): Starting VM using VBoxManage interface. (boinc_7119dfb4c886e358, slot#0) 2025-02-21 18:44:06 (22316): Error in start VM for VM: 1 Command: VBoxManage -q startvm "boinc_7119dfb4c886e358" --type headless Output: VBoxManage.exe: error: The virtual machine 'boinc_7119dfb4c886e358' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\0\boinc_7119dfb4c886e358\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_7119dfb4c886e358" to power on... 2025-02-21 18:44:06 (22316): VM failed to start. 2025-02-21 18:44:06 (22316): Could not start 2025-02-21 18:44:06 (22316): ERROR: VM failed to start 2025-02-21 18:44:06 (22316): Powering off VM. 2025-02-21 18:44:06 (22316): Deregistering VM. (boinc_7119dfb4c886e358, slot#0) 2025-02-21 18:44:06 (22316): Removing network bandwidth throttle group from VM. 2025-02-21 18:44:07 (22316): Removing VM from VirtualBox. Hypervisor System Log: 00:00:07.566508 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.566586 Saving settings file "C:\Users\timpl\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:07.569154 Finished saving settings file "C:\Users\timpl\.VirtualBox\VirtualBox.xml" 00:00:07.569390 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_7119dfb4c886e358\boinc_7119dfb4c886e358.vbox" with version "1.19-windows" 00:00:07.571122 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_7119dfb4c886e358\boinc_7119dfb4c886e358.vbox" 00:00:07.830730 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_7119dfb4c886e358\boinc_7119dfb4c886e358.vbox" with version "1.19-windows" 00:00:07.833065 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_7119dfb4c886e358\boinc_7119dfb4c886e358.vbox" 00:00:08.094592 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.094853 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_7119dfb4c886e358\boinc_7119dfb4c886e358.vbox" with version "1.19-windows" 00:00:08.095923 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_7119dfb4c886e358\boinc_7119dfb4c886e358.vbox" 00:00:08.096017 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.097204 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_7119dfb4c886e358\boinc_7119dfb4c886e358.vbox" with version "1.19-windows" 00:00:08.098358 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_7119dfb4c886e358\boinc_7119dfb4c886e358.vbox" 00:00:08.098630 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_7119dfb4c886e358\boinc_7119dfb4c886e358.vbox" with version "1.19-windows" 00:00:08.099764 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_7119dfb4c886e358\boinc_7119dfb4c886e358.vbox" 00:00:08.363633 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.364232 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.364311 Saving settings file "C:\Users\timpl\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:08.365574 Finished saving settings file "C:\Users\timpl\.VirtualBox\VirtualBox.xml" 00:00:08.365716 Saving settings file "C:\Users\timpl\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:08.366748 Finished saving settings file "C:\Users\timpl\.VirtualBox\VirtualBox.xml" 00:00:08.366971 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_7119dfb4c886e358\boinc_7119dfb4c886e358.vbox" with version "1.19-windows" 00:00:08.368142 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_7119dfb4c886e358\boinc_7119dfb4c886e358.vbox" 00:00:08.626242 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_7119dfb4c886e358\boinc_7119dfb4c886e358.vbox" with version "1.19-windows" 00:00:08.628529 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_7119dfb4c886e358\boinc_7119dfb4c886e358.vbox" 00:00:08.893409 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_7119dfb4c886e358\boinc_7119dfb4c886e358.vbox" with version "1.19-windows" 00:00:08.894824 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_7119dfb4c886e358\boinc_7119dfb4c886e358.vbox" 00:00:09.416403 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_7119dfb4c886e358\boinc_7119dfb4c886e358.vbox" with version "1.19-windows" 00:00:09.418555 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_7119dfb4c886e358\boinc_7119dfb4c886e358.vbox" 00:00:09.683265 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={Ńo extension pack providing a cryptographic support module could be found}, preserve=false aResultDetail=0 00:00:09.685332 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.685368 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.688616 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:09.946916 Launched VM: 1515030304 pid: 8596 (0x2194) frontend: headless name: boinc_7119dfb4c886e358 00:00:10.302815 Watcher ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The virtual machine 'boinc_7119dfb4c886e358' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\0\boinc_7119dfb4c886e358\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0 00:00:10.303526 Watcher Reaper: Pid 8596 (0x2194) exited normally: 1 (0x1) 00:00:10.339141 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:10.366154 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_7119dfb4c886e358\boinc_7119dfb4c886e358.vbox" with version "1.19-windows" 00:00:10.367432 Finished saving settings file "C:\ProgramData\BOINC\slots\0\boinc_7119dfb4c886e358\boinc_7119dfb4c886e358.vbox" 00:00:10.628669 Saving settings file "C:\Users\timpl\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:10.631310 Finished saving settings file "C:\Users\timpl\.VirtualBox\VirtualBox.xml" 00:00:10.631346 Saving settings file "C:\Users\timpl\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:10.632459 Finished saving settings file "C:\Users\timpl\.VirtualBox\VirtualBox.xml" 00:00:10.632950 DeleteVM Saving settings file "C:\Users\timpl\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:10.634216 DeleteVM Finished saving settings file "C:\Users\timpl\.VirtualBox\VirtualBox.xml" 00:00:15.637470 main VirtualBox: object deletion starts 00:00:15.638288 main HostDnsMonitor: shutting down ... 00:00:15.638348 main HostDnsMonitor: shut down 00:00:15.640063 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:15.640227 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: a\BOINC\slots\0/vm_image.vdi" Exit Code: -2135228412 Output: VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\0\vm_image.vdi' (VERR_FILE_NOT_FOUND) VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 205 of file VBoxManageDisk.cpp 2025-02-21 18:43:58 (22316): Command: VBoxManage -q createvm --name "boinc_7119dfb4c886e358" --basefolder "C:\ProgramData\BOINC\slots\0" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_7119dfb4c886e358' is created and registered. UUID: e89f8261-cd20-427f-8e7b-b575374ca3f5 Settings file: 'C:\ProgramData\BOINC\slots\0\boinc_7119dfb4c886e358\boinc_7119dfb4c886e358.vbox' 2025-02-21 18:43:58 (22316): Command: VBoxManage -q modifyvm "boinc_7119dfb4c886e358" --description "OlQNDmNJn56nsSi4ap6QjLDmwznN0nGgGQJmkKkKDmFqsKDmvBoCEo_0" Exit Code: 0 Output: 2025-02-21 18:43:58 (22316): Command: VBoxManage -q modifyvm "boinc_7119dfb4c886e358" --memory 4600 Exit Code: 0 Output: 2025-02-21 18:43:58 (22316): Command: VBoxManage -q modifyvm "boinc_7119dfb4c886e358" --cpus 6 Exit Code: 0 Output: 2025-02-21 18:43:59 (22316): Command: VBoxManage -q modifyvm "boinc_7119dfb4c886e358" --acpi on --ioapic on --rtcuseutc off Exit Code: 0 Output: 2025-02-21 18:43:59 (22316): Command: VBoxManage -q modifyvm "boinc_7119dfb4c886e358" --vram 16 --graphicscontroller VBoxVGA Exit Code: 0 Output: 2025-02-21 18:43:59 (22316): Command: VBoxManage -q modifyvm "boinc_7119dfb4c886e358" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2025-02-21 18:43:59 (22316): Command: VBoxManage -q modifyvm "boinc_7119dfb4c886e358" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2025-02-21 18:44:00 (22316): Command: VBoxManage -q modifyvm "boinc_7119dfb4c886e358" --cableconnected1 on Exit Code: 0 Output: 2025-02-21 18:44:00 (22316): Command: VBoxManage -q modifyvm "boinc_7119dfb4c886e358" --usb off Exit Code: 0 Output: 2025-02-21 18:44:00 (22316): Command: VBoxManage -q modifyvm "boinc_7119dfb4c886e358" --uart1 off --uart2 off Exit Code: 0 Output: 2025-02-21 18:44:00 (22316): Command: VBoxManage -q modifyvm "boinc_7119dfb4c886e358" --lpt1 off --lpt2 off Exit Code: 0 Output: 2025-02-21 18:44:01 (22316): Command: VBoxManage -q modifyvm "boinc_7119dfb4c886e358" --audio none Exit Code: 0 Output: Warning: --audio is deprecated and will be removed soon. Use --audio-driver instead! 2025-02-21 18:44:01 (22316): Command: VBoxManage -q modifyvm "boinc_7119dfb4c886e358" --clipboard disabled Exit Code: 0 Output: 2025-02-21 18:44:01 (22316): Command: VBoxManage -q modifyvm "boinc_7119dfb4c886e358" --draganddrop disabled Exit Code: 0 Output: 2025-02-21 18:44:02 (22316): Command: VBoxManage -q storagectl "boinc_7119dfb4c886e358" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2025-02-21 18:44:02 (22316): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: UUID: ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8 Parent UUID: base State: created Type: multiattach Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 4204 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-21 18:44:02 (22316): Command: VBoxManage -q storageattach "boinc_7119dfb4c886e358" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: -2135228409 Output: VBoxManage.exe: error: Cannot attach medium 'C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 785 of file VBoxManageStorageController.cpp 2025-02-21 18:44:02 (22316): Command: VBoxManage -q closemedium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-21 18:44:04 (22316): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: UUID: ba4f7346-8ee8-4da6-a071-5ab41c7f9cb8 Parent UUID: base State: created Type: normal (base) Location: C:\ProgramData\BOINC\projects\lhcathome.cern.ch_lhcathome\ATLAS_vbox_3.01_image.vdi Storage format: VDI Format variant: dynamic default Capacity: 20480 MBytes Size on disk: 4204 MBytes Encryption: disabled Property: AllocationBlockSize=1048576 2025-02-21 18:44:04 (22316): Command: VBoxManage -q storageattach "boinc_7119dfb4c886e358" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-21 18:44:04 (22316): Command: VBoxManage -q storageattach "boinc_7119dfb4c886e358" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none Exit Code: 0 Output: 2025-02-21 18:44:04 (22316): Command: VBoxManage -q storageattach "boinc_7119dfb4c886e358" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/lhcathome.cern.ch_lhcathome/ATLAS_vbox_3.01_image.vdi" Exit Code: 0 Output: 2025-02-21 18:44:05 (22316): Command: VBoxManage -q storageattach "boinc_7119dfb4c886e358" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2025-02-21 18:44:05 (22316): Command: VBoxManage -q bandwidthctl "boinc_7119dfb4c886e358" add "boinc_7119dfb4c886e358_net" --type network --limit 1024G Exit Code: 0 Output: 2025-02-21 18:44:05 (22316): Command: VBoxManage -q modifyvm "boinc_7119dfb4c886e358" --natpf1 ",tcp,127.0.0.1,65149,,80" Exit Code: 0 Output: 2025-02-21 18:44:05 (22316): Command: VBoxManage -q list extpacks Exit Code: 0 Output: Extension Packs: 0 2025-02-21 18:44:06 (22316): Command: VBoxManage -q sharedfolder add "boinc_7119dfb4c886e358" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\0/shared" Exit Code: 0 Output: 2025-02-21 18:44:06 (22316): Command: VBoxManage -q startvm "boinc_7119dfb4c886e358" --type headless Exit Code: 1 Output: VBoxManage.exe: error: The virtual machine 'boinc_7119dfb4c886e358' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\0\boinc_7119dfb4c886e358\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine Waiting for VM "boinc_7119dfb4c886e358" to power on... 2025-02-21 18:44:06 (22316): Command: VBoxManage -q snapshot "boinc_7119dfb4c886e358" list Exit Code: -108 Output: This machine does not have any snapshots 2025-02-21 18:44:07 (22316): Command: VBoxManage -q bandwidthctl "boinc_7119dfb4c886e358" remove "boinc_7119dfb4c886e358_net" Exit Code: 0 Output: 2025-02-21 18:44:07 (22316): Command: VBoxManage -q unregistervm "boinc_7119dfb4c886e358" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 18:44:12 (22316): called boinc_finish(1) </stderr_txt> ]]>
©2025 CERN